Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
77
3
Commissioning
3.8
Commissioning of the "Table positioning" technology application
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.8.4.4
Enter one or more profiles
1. Click the
Profile entry
button (in the "MotionControlKernel" block) in the signal flow to change
to the
Overview
Signal flow
Profile entry
dialog level:
2. Select number 3 in the
Profile number
list field to enter a positioning profile which can be
selected via digital inputs DI5 and DI6.
You can find detailed information on entering profiles in the chapter entitled "Basic drive
functions", subchapter "
Note!
In the Lenze setting, the profiles are assigned to certain operating modes, i.e. the
selection of a profile also results in a change of operating mode:
• If profile 0 is selected: Activation of "Speed follower" operating mode
• If profile 1 is selected: Activation of "Homing" operating mode
• If profile 2 is selected: Activation of "Manual jog" operating mode