3
Commissioning
3.8
Commissioning of the "Table positioning" technology application
68
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.8.1
Prepare inverter for commissioning
1. Wire the power connections
Refer to the mounting instructions supplied with the inverter to find help on how to correctly
design the power connections to match the requirements of your device.
2. Wire the control connections
The system constellation including position encoder and hardware limit switches shown in
illustration
requires wiring according to control mode "
":
3. Inhibit inverter: Set terminal X5/RFR to LOW level or open contact.
4. Connect USB diagnostic adapter.
5. Switch on voltage supply of the inverter.
• Without motor operation: Connect external 24 V supply.
• With motor operation: Connect mains voltage.
If the green "DRV-RDY" LED is blinking and the red "DRV-ERR" LED is off, the inverter is ready for
operation and commissioning can proceed.
Related topics:
Automatic restart after mains connection/fault...