
17
Function library
17.1
Function blocks | L_SignalSwitch_4
1505
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.157
L_SignalSwitch_4
This FB switches between two input signals of the "WORD" data type. The switch-over is controlled
by means of a boolean input signal.
Inputs
Outputs
Designator
Data type
Information/possible settings
wIn1
WORD
Input signal 1
wIn2
WORD
Input signal 2
bSet
BOOL
Selection of the input signal for the output at
wOut
FALSE
wIn1
TRUE
wIn2
Designator
Data type
Value/meaning
wOut
WORD
Output signal
/B6LJQDO6ZLWFKB
Z,Q
Z2XW
Z,Q
E6HW