Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
1420
17
Function library
17.1
Function blocks | L_MulDiv_1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.104
L_MulDiv_1
This FB multiplies the analog input signal with a parameterisable factor.
• The value of the factor is determined by a quotient consisting of numerator and denominator .
• The value output at
nOut_a
is limited to ±199.99 %.
• Division is not remainder considered.
Inputs
Outputs
Parameters
Function
Designator
Data type
Information/possible settings
nIn1
INT
Input signal
Designator
Data type
Value/meaning
nOut_a
INT
Product value (result of the multiplication)
• Internal limitation to ± 32767
Parameters
Possible settings
Info
-32767
32767 Counter
-32767
32767 Denominator
/B0XO'LYB
Q,QBD
Q2XWBD
&
&
nOut_a
nIn_a C00699/1
C00699/2
-------------------------
×
=