17
Function library
17.1
Function blocks | L_Limit_2
1401
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.98
L_Limit_2
This FB limits an analog input signal to a value range whose upper and lower limit can be set via
parameters.
Inputs
Outputs
Parameters
Tip!
Always set the lower limit lower than the upper limit, otherwise value "0" is provided at the
nOut_a
output.
Designator
Data type
Information/possible settings
nIn_a
INT
Input signal
• Scaling: 16384
≡
100 %
Designator
Data type
Value/meaning
nOut_a
INT
Output signal
• Scaling: 16384
≡
100 %
Parameters
Possible settings
Info
-199.99
%
199.99 Lower limit
• Lenze setting: -100.00 %
-199.99
%
199.99 Upper limit
• Lenze setting: 100.00 %
/B/LPLWB
Q,QBD
Q2XWBD
&
&