Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
1139
15
Parameter reference
15.2
Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02652
C02810
Parameter | Name:
C02652 | Settings of measuring system
Data type: UNSIGNED_16
Index: 21923
d
= 55A3
h
From version 11.00.00
Setting range
(min. hex value | max. hex value)
Lenze setting
0x0000
0xFFFF
0x0000
(decimal: 0)
Value is bit-coded: (
= bit set)
Info
Bit 0
Actual MCTRL position received at
mains switch-off
Actual "MCTRL position received at mains switch-off"
Bit 1
Delete reference when machine data
is changed
From version 12.00.00
Bit 2
Reserved
Bit 3
Reserved
Bit 4
Reserved
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15
Reserved
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Parameter | Name:
C02810 | TP: Edge selection
Data type: UNSIGNED_8
Index: 21765
d
= 5505
h
From version 06.00.00
Selection list
0 Off
1 Rising
2 Falling
3 Rising and falling
Subcodes
Lenze setting
Info
C02810/1
0: Off
Reserved
C02810/2
0: Off
Reserved
C02810/3
0: Off
TPDigIn3: Edge selection
C02810/4
0: Off
TPDigIn4: Edge selection
C02810/5
0: Off
TPDigIn5: Edge selection
C02810/6
0: Off
TPDigIn6: Edge selection
C02810/7
0: Off
TPDigIn7: Edge selection
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1