C02274
C02275
C02276
C02273/5
120.00 %
: c909_s2_val1
C02273/6
120.00 %
: c909_s2_val2
C02273/7
120.00 %
: c909_s2_val3
C02273/8
120.00 %
: c909_s2_val4
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C02273 | LS_WriteParamList: Speed limitation
Data type: INTEGER_16
Index: 22302
d
= 571E
h
Parameter | Name:
C02274 | LS_WriteParamList: Frequency limitation
Data type: UNSIGNED_16
Index: 22301
d
= 571D
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0
Hz
1300
Subcodes
Lenze setting
Info
C02274/1
1000 Hz
: c910_s1_val1
C02274/2
1000 Hz
: c910_s1_val2
C02274/3
1000 Hz
: c910_s1_val3
C02274/4
1000 Hz
: c910_s1_val4
C02274/5
1000 Hz
: c910_s2_val1
C02274/6
1000 Hz
: c910_s2_val2
C02274/7
1000 Hz
: c910_s2_val3
C02274/8
1000 Hz
: c910_s2_val4
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C02275 | LS_WriteParamList: Motor cable length
Data type: UNSIGNED_16
Index: 22300
d
= 571C
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.0
m
1000.0
Subcodes
Lenze setting
Info
C02275/1
5.0 m
: c915_val1
C02275/2
5.0 m
: c915_val2
C02275/3
5.0 m
: c915_val3
C02275/4
5.0 m
: c915_val4
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 10
Parameter | Name:
C02276 | LS_WriteParamList: Motor cable cross-section
Data type: UNSIGNED_16
Index: 22299
d
= 571B
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.50
mm^2
100.00
Subcodes
Lenze setting
Info