15
Parameter reference
15.2
Parameter list
1114
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02240
C02241
C02242
Parameter | Name:
C02240 | LS_WriteParamList: Motor cosine phi
Data type: UNSIGNED_8
Index: 22335
d
= 573F
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.20
1.00
Subcodes
Lenze setting
Info
C02240/1
0.85
: c91_val1
C02240/2
0.85
: c91_val2
C02240/3
0.85
: c91_val3
C02240/4
0.85
: c91_val4
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C02241 | LS_WriteParamList: Motor magnetizing inductance
Data type: UNSIGNED_16
Index: 22334
d
= 573E
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.0
mH
6500.0
Subcodes
Lenze setting
Info
C02241/1
81.0 mH
: c92_val1
C02241/2
81.0 mH
: c92_val2
C02241/3
81.0 mH
: c92_val3
C02241/4
81.0 mH
: c92_val4
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 10
Parameter | Name:
C02242 | LS_WriteParamList: Motor magnetising current
Data type: UNSIGNED_16
Index: 22333
d
= 573D
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.00
A
320.00
Subcodes
Lenze setting
Info
C02242/1
8.50 A
: c95_val1
C02242/2
8.50 A
: c95_val2
C02242/3
8.50 A
: c95_val3
C02242/4
8.50 A
: c95_val4
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100