15
Parameter reference
15.2
Parameter list
1084
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01247
Selection list
0 No TP
3 TP-DigIn3
4 TP-DigIn4
5 TP-DigIn5
6 TP-DigIn6
7 TP-DigIn7
Subcodes
Lenze setting
Info
C01246/1
0: No TP
MCK: Ref. TP signal source
Note:
In case of setting "0: No TP", the digital input DI3 is used
as signal source for reference search. An inversion of DI3
is considered.
C01246/2
0: No TP
MCK: Set.Ref. signal source
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01246 | MCK: Select signal source
Data type: UNSIGNED_8
Index: 23329
d
= 5B21
h
Parameter | Name:
C01247 | MCK: Diagnostic word
Data type: UNSIGNED_32
Index: 23328
d
= 5B20
h
From version 15.00.00
Display area
(min. hex value | max. hex value)
0x00000000
0xFFFFFFFF
Value is bit-coded:
Info
Bit 0 Traversing range: Limited
1
≡
The traversing range is limited:
• The software limit positions are set.
• The reference is known.
• There is no modulo measuring system available
= 0).
Note:
This status does not consider whether the software limit
positions are activated or deactivated by the settings in
the prevailing operating mode.
Bit 1 Traversing range: Modulo
1
≡
A modulo measuring system is available as a cycle
length has been set in
Bit 2 Pos. HW limit switch active
Evaluation of travel range limit switch active in positive
direction
Bit 3 Neg. HW limit switch active
Evaluation of travel range limit switch active in negative
direction
Bit 4 Pos. SW-Limit active
Evaluation of software limit positions active in positive
direction
Bit 5 Neg. SW-Limit active
Evaluation of software limit positions active in negative
direction
Bit 6
Reserved
Bit 7
Reserved
Bit 8 SpeedNormConstant: Low-Limit
1
≡
Due to the set machine parameters, an internal
calculation constant is limited to a possible minimum.
Remedy: Increase reference speed in
.
Bit 9 SpeedNormConstant: Up-Limit
1
≡
Due to the set machine parameters, an internal
calculation constant is limited to a possible maximum.