15
Parameter reference
15.2
Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01001
C01010
Bit 4 Encoder open circuit: V/f linear active
From version 15.00.00
1
≡
Due to an encoder open circuit, it has been internally
switched to the encoderless V/f characteristic control to
avoid impermissible motor movements.
Bit 5 Speed limit. C909/C910/fdmax
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15
Reserved
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Parameter | Name:
C01000 | MCTRL: Status
Data type: UNSIGNED_16
Index: 23575
d
= 5C17
h
Parameter | Name:
C01001 | Manual entry of motor type
Data type: UNSIGNED_8
Index: 23574
d
= 5C16
h
From version 14.00.00
Selection list
0 Automatic
1 ASM
2 PSM
Subcodes
Lenze setting
Info
C01001/1
0: Automatic
Manual entry of motor type
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01010 | L_ArithmetikPhi 1-3: Function
Data type: UNSIGNED_8
Index: 23565
d
= 5C0D
h
Selection of the internal arithmetics
Selection list
0 dnIn1_p
1 d dnIn2_p
2 dnIn1_p - dnIn2_p
3 dnIn1_p * dnIn2_p
4 dnIn1_p / dnIn2_p
Subcodes
Lenze setting
Info
C01010/1
0: dnIn1_p
: Function
C01010/2
0: dnIn1_p
: Function
C01010/3
0: dnIn1_p
: Function
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1