15
Parameter reference
15.2
Parameter list
1026
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00952
C00953
C00959
C00960
Parameter | Name:
C00952 | L_Interpolator_1: Limit value - error cycles
Data type: UNSIGNED_16
Index: 23623
d
= 5C47
h
From version 04.00.00
The
FB: Limit value for missing data telegrams
Setting range
(min. value | unit | max. value)
Lenze setting
0
65535
5
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00953 | L_Interpolator_1: Speed-up
Data type: UNSIGNED_8
Index: 23622
d
= 5C46
h
From version 04.00.00
FB
: Limitation of the number of correction increments per cycle (speed-up)
Setting range
(min. value | unit | max. value)
Lenze setting
0
100
0
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00959 | L_Curve: Current output value
Data type: INTEGER_16
Index: 23616
d
= 5C40
h
From version 11.00.00
FB
: Display of the current output value
nOut_a
Display range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Info
C00959/1
: Current output value
C00959/2
: Current output value
C00959/3
: Current output value
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00960 | L_Curve_1: Selected curve type
Data type: UNSIGNED_8
Index: 23615
d
= 5C3F
h
From version 04.00.00
FB
: Selected curve type
Selection list
0 Out = 0
1 Out = In
2 Out = f(In)
3 Out = f(table)
Subcodes
Lenze setting
Info
C00960/1
1: Out = In
: Function
Read access
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1