background image

Dimensions

Basic dimensions
Notes on the basic dimensions
The following legend shows the layout of the dimension tables:

 

 

 

 

 

Motor

m540-P

90/L4

100/M4

100/L4

 Table content

 

Explanation

 

 Total length

L

Total length of the drive without brake/feedback

 

 Motor length

LB

Length of the motor without brake/feedback

 

 Motor diameter

AC

Motor diameter

 

 Motor/connection distance

AD

Distance from center of motor to end of terminal box

 

  

 

 

 

Technical data

Dimensions

Basic dimensions

68

Содержание IE3 g500-B

Страница 1: ...Geared motors IE3 g500 B m540 P bevel geared motor Project planning EN...

Страница 2: ......

Страница 3: ...n on project planning 19 Safety instructions 19 Basic safety instructions 20 Application as directed 21 Foreseeable misuse 21 Residual hazards 22 General information 24 Drive dimensioning 27 Final con...

Страница 4: ...orque plates 80 Shaft covers 81 Motor connection 83 Connection options 83 Assignment of the terminal boxes 84 Assignment of the connectors HAN 88 Connection via terminal box 90 Connection via HAN conn...

Страница 5: ...ent includes safety instructions which must be observed All persons working on and with the drives must have the documentation at hand during work and observe the information and notes relevant for it...

Страница 6: ...er documentation with additional information Example EDKxxx see documentation EDKxxx Layout of the safety instructions DANGER Indicates an extremely hazardous situation Failure to comply with this ins...

Страница 7: ...achine integration Low backlash and high torsional rigidity during positioning provide for exact results Three phase AC motors for mains and inverter operation In a power range from 1 5 to 55 kW Lenze...

Страница 8: ...range of machine tasks due to the market oriented modular system Simple plug in motor mounting Mounting motors according to IEC 72 DIN 42948 Mounting motors according to NEMA C TC Mounting servo motor...

Страница 9: ...h Medium M Long L Number of pole pairs 4 pole 4 Features The following figure provides an overview of the elements and connections on the product Their position size and appearance may vary Oil drain...

Страница 10: ...Solid shaft with featherkey V mm 90 x 170 110 x 210 120 x 210 Hollow shaft with keyway H mm 90 100 120 Hollow shaft with shrink disc S mm 95 105 125 Shaft material Steel Output shaft bearing Standard...

Страница 11: ...ilable gearbox designs 4The modular system 10 g500 B8000 Hollow shaft with foot Without centring HBR Hollow shaft without foot Without centring HDR With centering HCR Flange with through holes HCK Pro...

Страница 12: ...t with shrink disc with foot Without centring SBR Hollow shaft with shrink disc without foot Without centring SDR With centring SCR Flange with through holes SCK Product information The modular system...

Страница 13: ...VBR Solid shaft without foot With centering VCR Flange with through holes VCK g500 B13000 B20000 Hollow shaft with foot Without centring HBR With centring HAR Flange with through holes HAK Product inf...

Страница 14: ...disc with foot Without centring SBR With centring SAR Flange with through holes SAK Solid shaft with foot Without centring VBR With centring VAR Flange with through holes VAK Product information The m...

Страница 15: ...of the defined positions refer to the areas on the geared motor in mounting position M1 A Position of the built on accessories with T L R B F E Top Left Right Bottom Front and End If the geared motor...

Страница 16: ...x Blower terminal box HAN connector with without ICN connector with without ICN connector R L B T R L B T R L B T Positions of the connections HAN connector R L E Position of the manual release lever...

Страница 17: ...rnal L R L R Position of the hollow shaft with shrink disc Output flange and shrink disc are not possible in the same position L R Position of the output flange Output flange on both sides L R L R Pro...

Страница 18: ...Position of the torque plate on the housing foot Position of the torque plate Position of the rubber buffer on the torque plate F B R R L L Product information The modular system Mounting positions 18...

Страница 19: ...personal injury and damage to property Observe all specifications of the corresponding documentation supplied This is the precondition for safe and trouble free operation and for obtaining the product...

Страница 20: ...ccording to the appropriate regulations e g cable cross sections fusing PE conductor connection Additional information can be obtained from this documentation This documentation contains notes about i...

Страница 21: ...C Directive 2014 30 EU The product is not a household appliance Instead it is a component that is intended exclusively for further use in the context of commercial or professional use as defined by EN...

Страница 22: ...ipment or wait until the device has cooled down Prevent contact with flammable substances Risk of injury from rotating parts Before working on the drive system ensure that the motor is at a standstill...

Страница 23: ...ed on the nameplate Lateral forces on the gearbox shaft are possible Align the shafts of gearboxes and driven machine exactly to each other Toothed parts may be damaged by a lack of lubricant Only use...

Страница 24: ...MA MS MK MN IA IN 0 2 0 4 0 6 0 8 nN nS nK 0 0 M MN n nN 1 0 2 3 4 5 I IN Operation on the frequency inverter Standard setting The frequency inverter is set for easy operation on a three phase AC moto...

Страница 25: ...C D m540 P A Operation with integral fan and brake B Operation with integral fan and brakes with a wide range voltage of DC 180 205 V or AC 400 460 V Operation with integral fan and holding current re...

Страница 26: ...e drive speeds given in the following are exceeded as a function of the mounting position Temporarily up to 5 min 30 higher speeds are permissible the ambient temperature is predominantly above 30 C G...

Страница 27: ...ne correction factor Operating modes and operating time Ambient temperature and installation height Determine gearbox type and efficiency Determine product on the basis of the active forces Calculate...

Страница 28: ...h Determine correction factor Operating modes S1 S2 S3 S6 and operating time Operating mode S1 Operating mode S2 Operating mode S3 Operating mode S6 ED kL ED kL ED kL ED kL min 100 1 0 10 1 4 1 5 15...

Страница 29: ...k kL Correction factor operating mode kTU Correction factor ambient temperature kH Correction factor site altitude G Gearbox efficiency Intensity and load class for mains operation Calculation Intens...

Страница 30: ...on factor Sh Switching rate Ratio of motor stalling torque rated torque 2 5 Ratio of motor stalling torque rated torque 2 5 Stalling rated motor torque 4Rated data 106 Check and select product Data 4S...

Страница 31: ...m Min Output speed Self ventilated n21 nL min rpm Adjustment range 2 5 50 Hz Adjustment range 4 35 87 Hz Forced ventilated n22 nL min rpm Adjustment range 10 50 Hz Adjustment range 17 4 87 Hz Self ven...

Страница 32: ...be chosen for the top coat Surface and corrosion protection Applications Product g500 H5000 H14000 g500 S8000 S19000 g500 B8000 B20000 OKS G primed Dependent on subsequent top coat applied Optionally...

Страница 33: ...Operating hours 25000 16000 25000 Not later than after 4 years 3 years 4 years At oil temperature 80 C Manufacturer Fuchs Kl ber Shell Fuchs Kl ber Fuchs Kl ber Shell Manufacturer series Renolin Unisy...

Страница 34: ...be observed to the machine wall on the corresponding gearbox side g500 B8000 B20000 Mounting position M1 A Mounting position M2 D Mounting position M3 B Filling and ventilation Check Drain Bore hole...

Страница 35: ...ng level is required in the gearbox As a result of the reduced volume of air in the gearbox this may lead to oil escaping from the ventilation at higher input speeds The oil compensation reservoir inc...

Страница 36: ...Dimensions of oil compensation reservoir Gearbox A1 L2 mm mm g500 B8000 376 166 g500 B13000 399 336 g500 B20000 427 336 Information on project planning Final configuration Ventilation 36...

Страница 37: ...parts Only use safely fixed transport aids e g eye bolts or support plates Do not damage any components during transport Avoid electrostatic discharges on electronic components and contacts Avoid impa...

Страница 38: ...e system or machine is responsible for adherence to the limits required in connection with EMC legislation Operation on an external inverter A max pulse voltage amplitude of Upk 1560 V at the motor te...

Страница 39: ...per hr TV 30 40 C Site altitude 1000 m above sea level The selection tables indicate the mechanically permissible power levels and torques The ratings apply to the operating mode S1 acc to EN 60034 NO...

Страница 40: ...Protection of persons and device protection Protection class EN EN 60529 EN 60034 5 IP55 Information applies to the mounted and ready for use state IP65 Temperature class Utilization EN 60034 1 B 130...

Страница 41: ...e max radial force refer to Gearbox design Solid shaft without flange output shaft bearing normal bearing Application factor c 1 3 Further designs4Radial forces and axial forces 49 In order to calcula...

Страница 42: ...58 4 7420 25 300 4959 196 8 51 6 7630 28 660 36917 1288 8 45 6 7760 32 330 12673 392 8 41 7 7850 35 400 80997 2288 7 34 0 8000 43 180 174783 4048 7 29 6 8000 49 600 8729 176 7 26 8 8000 54 760 55419...

Страница 43: ...56 7 50 1 13000 29 430 25721 874 7 48 0 13000 30 750 42809 1392 7 37 6 13000 39 330 141599 3600 6 32 8 13000 44 860 55981 1248 6 26 8 13000 54 680 181115 3312 6 23 7 13000 62 070 62567 1008 6 21 7 13...

Страница 44: ...6 41 2 19500 35 670 193452 5423 6 33 0 19500 44 760 209244 4675 6 29 3 19500 50 340 122388 2431 6 24 3 19500 60 580 23688 391 6 21 9 19500 67 360 12596 187 6 19 7 19500 74 350 319788 4301 6 17 6 1950...

Страница 45: ...n positive power transmission Suitable for reversing duty Tension ring hub without keyway Non positive power transmission Suitable for reversing duty Versions with plug in hollow shaft Adapter Plug in...

Страница 46: ...1039 37 0 45 0 225 60 140 FT400 T76 962 1037 1085 55 0 250 65 140 FT500 T81 994 1074 1119 75 0 90 0 280 75 140 FT500 T82 950 996 110 132 315 80 170 FT600 T86 1020 Versions with plug in hollow shaft M...

Страница 47: ...625 9 000 A28 871 952 1002 324 326 TC 2 125 5 250 11 000 A32 955 1029 1078 364 365 TC 2 375 5 875 11 000 A36 1002 1083 1128 Versions with plug in hollow shaft Motor Adapter Gearbox g500 Size Shaft Siz...

Страница 48: ...th jaw coupling Motor Adapter Gearbox g500 Shaft Size B8000 B13000 B20000 M d l M L L L mm mm mm mm mm mm mm 130 24 50 FT130 E06 665 165 32 58 FT165 E08 700 786 837 215 38 80 FT215 E10 767 848 898 300...

Страница 49: ...x Permissible axial force If there is no radial force the maximum axial force is 50 of the value in the table Frad max Fax zul 0 5 x Frad max Application of forces Fax Frad Frad Fax l x l x Additional...

Страница 50: ...speed n2 rpm 160 100 63 40 25 16 Max radial force Frad max N g500 B8000 32000 35000 38000 45000 55000 65000 g500 B13000 45000 45000 53000 65000 70000 70000 g500 B20000 76000 90000 104000 104000 10400...

Страница 51: ...operation Geared motor Mains operation 5 Hz 20 Hz 50 Hz 1 10 87 Hz 1 17 4 n22 M22 n21 M2 n2 M2 c n2 M2 c J i z m rpm Nm rpm Nm rpm Nm rpm Nm kgcm2 kg 1 0 735 5 1 1335 10 3 1335 6 0 65 000 140 930 g50...

Страница 52: ...3 271 1 3 850 6 5 1540 13 0 1540 5 2 22 9 1540 5 2 163 000 112 680 g500 B8000 m540 P100 M4 3 271 1 1 959 5 8 1738 11 5 1738 4 6 20 3 1738 4 6 159 000 127 160 g500 B8000 m540 P100 M4 3 271 1 0 1063 5 2...

Страница 53: ...10 4 2641 3 0 18 2 2641 3 0 156 000 140 930 g500 B8000 m540 P100 L4 3 271 1 0 1553 4 8 2821 9 7 2821 4 6 17 1 2821 4 6 173 000 150 550 g500 B13000 m540 P100 L4 3 457 0 9 1637 4 6 2973 9 2 2973 2 7 16...

Страница 54: ...11 0 3312 3 9 19 4 3312 3 9 210 000 132 240 g500 B13000 m540 P112 M4 3 457 1 0 1939 5 2 3530 10 4 3530 2 3 18 2 3530 2 3 186 000 140 930 g500 B8000 m540 P112 M4 3 271 1 0 1957 5 1 3564 10 3 3564 5 5 1...

Страница 55: ...00 B20000 m540 P132 M4 3 735 1 2 2251 6 1 4090 12 3 4090 3 2 21 5 4090 3 2 387 000 119 830 g500 B13000 m540 P132 M4 3 485 1 1 2389 5 8 4340 11 6 4340 1 8 20 3 4340 1 8 359 000 127 160 g500 B8000 m540...

Страница 56: ...7 4665 1 7 25 8 4665 1 6 486 000 99 790 g500 B8000 m540 P132 L4 3 299 1 4 2688 7 0 4888 14 0 4888 4 0 24 6 4888 3 8 560 000 104 560 g500 B20000 m540 P132 L4 3 735 1 4 2743 6 9 4989 13 7 4989 2 6 24 1...

Страница 57: ...4803 1 6 873 000 70 560 g500 B8000 m540 P160 M4 3 315 2 0 2784 10 0 5061 19 8 5061 3 9 34 8 5061 3 7 994 000 74 350 g500 B20000 m540 P160 M4 3 751 1 9 2855 9 7 5189 19 3 5189 2 5 33 9 5189 2 4 918 000...

Страница 58: ...20 Hz 50 Hz 1 10 87 Hz 1 17 4 n22 M22 n21 M2 n2 M2 c n2 M2 c J i z m rpm Nm rpm Nm rpm Nm rpm Nm kgcm kg 0 6 8362 3 3 15199 6 6 15199 0 9 11 6 15199 0 9 848 000 223 300 g500 B13000 m540 P160 M4 3 501...

Страница 59: ...1170 000 44 860 g500 B13000 m540 P160 L4 3 518 2 9 2532 14 9 4604 29 7 4604 1 7 52 1 4604 1 7 1060 000 49 600 g500 B8000 m540 P160 L4 3 332 2 9 2570 14 7 4673 29 3 4673 4 2 51 4 4673 4 0 1263 000 50...

Страница 60: ...L4 3 518 0 9 8219 4 6 14943 9 2 14943 1 3 16 1 14943 1 3 1040 000 160 980 g500 B20000 m540 P160 L4 3 768 0 9 8491 4 4 15438 8 9 15438 0 8 15 5 15438 0 8 1018 000 166 310 g500 B13000 m540 P160 L4 3 518...

Страница 61: ...7 2486 18 7 4519 37 4 4519 2 9 65 6 4519 2 4 1498 000 39 330 g500 B13000 m540 P180 M4 3 593 3 4 2729 17 0 4962 34 0 4962 1 6 59 7 4962 1 5 1385 000 43 180 g500 B8000 m540 P180 M4 3 407 3 2 2829 16 4...

Страница 62: ...1449 000 32 330 g500 B8000 m540 P180 L4 3 412 4 1 2660 20 8 4836 41 5 4836 1 6 72 9 4836 1 4 1510 000 35 400 g500 B8000 m540 P180 L4 3 412 4 1 2680 20 6 4873 41 2 4873 4 0 72 3 4873 3 3 1855 000 35 6...

Страница 63: ...1 000 27 020 g500 B13000 m540 P200 M4 3 668 5 1 2909 25 9 5290 51 8 5290 3 7 90 9 5290 3 1 2786 000 28 390 g500 B20000 m540 P200 M4 3 918 5 1 2937 25 6 5340 51 3 5340 1 4 90 0 5340 1 2 2259 000 28 660...

Страница 64: ...225 M4 3 713 5 7 3169 29 2 5783 58 4 5783 1 3 102 5783 1 1 4273 000 25 300 g500 B8000 m540 P225 M4 3 527 5 7 3177 29 2 5799 58 3 5799 3 4 102 5799 2 8 4535 000 25 370 g500 B20000 m540 P225 M4 3 963 5...

Страница 65: ...606 1 3 128 5606 1 1 4803 000 20 150 g500 B8000 m540 P225 L4 3 562 6 9 3226 35 1 5867 70 1 5867 3 3 123 5867 2 8 5139 000 21 090 g500 B20000 m540 P225 L4 3 998 6 5 3403 33 3 6190 66 4 6190 1 2 116 619...

Страница 66: ...7 3495 39 5 6345 79 0 6345 3 1 139 5736 2 8 9045 000 18 750 g500 B20000 m540 P250 M4 3 1098 7 4 3641 37 9 6609 75 9 6609 1 9 133 5975 1 8 8749 000 19 530 g500 B13000 m540 P250 M4 3 848 7 2 3756 36 7...

Страница 67: ...E84AVXXX1834 22 m540 P180 L4 E84AVXXX2234 30 m540 P200 M4 E84AVXXX3034 37 m540 P225 M4 E84AVXXX3734 45 m540 P225 L4 E84AVXXX4534 Rated frequency 87 Hz Rated power Motor Inverter kW 2 6 m540 P90 L4 E8...

Страница 68: ...P 90 L4 100 M4 100 L4 Table content Explanation Total length L Total length of the drive without brake feedback Motor length LB Length of the motor without brake feedback Motor diameter AC Motor diame...

Страница 69: ...225L4 250M4 Total length L mm 897 941 941 1017 1049 1109 1122 1152 1215 1241 1301 1301 Motor length LB mm 349 393 393 469 501 561 574 604 667 693 753 753 Motor diameter AC mm 174 198 222 264 318 318 3...

Страница 70: ...4 225M4 225L4 250M4 Total length L mm 897 941 941 1017 1049 1109 1122 1152 1215 1241 1301 1301 Motor length LB mm 349 393 393 469 501 561 574 604 667 693 753 753 Motor diameter AC mm 174 198 222 264 3...

Страница 71: ...25L4 250M4 Total length L mm 897 941 941 1017 1049 1109 1122 1152 1215 1241 1301 1301 Motor length LB mm 349 393 393 469 501 561 574 604 667 693 753 753 Motor diameter AC mm 174 198 222 264 318 318 35...

Страница 72: ...225L4 250M4 Total length L mm 1026 1026 1097 1129 1189 1202 1232 1295 1316 1376 1427 Motor length LB mm 391 391 462 494 554 567 597 660 681 741 792 Motor diameter AC mm 198 222 264 318 318 353 353 39...

Страница 73: ...0M4 225M4 225L4 250M4 Total length L mm 1026 1026 1097 1129 1189 1202 1232 1295 1316 1376 1427 Motor length LB mm 391 391 462 494 554 567 597 660 681 741 792 Motor diameter AC mm 198 222 264 318 318 3...

Страница 74: ...225L4 250M4 Total length L mm 1026 1026 1097 1129 1189 1202 1232 1295 1316 1376 1427 Motor length LB mm 391 391 462 494 554 567 597 660 681 741 792 Motor diameter AC mm 198 222 264 318 318 353 353 39...

Страница 75: ...5M4 225L4 250M4 Total length L mm 1077 1147 1179 1239 1252 1282 1345 1364 1424 1472 Motor length LB mm 379 449 481 541 554 584 647 666 726 774 Motor diameter AC mm 222 264 318 318 353 353 393 439 439...

Страница 76: ...200M4 225M4 225L4 250M4 Total length L mm 1077 1147 1179 1239 1252 1282 1345 1364 1424 1472 Motor length LB mm 379 449 481 541 554 584 647 666 726 774 Motor diameter AC mm 222 264 318 318 353 353 393...

Страница 77: ...M4 225L4 250M4 Total length L mm 1077 1147 1179 1239 1252 1282 1345 1364 1424 1472 Motor length LB mm 379 449 481 541 554 584 647 666 726 774 Motor diameter AC mm 222 264 318 318 353 353 393 439 439 4...

Страница 78: ...pring applied brake and feedback L mm 242 364 350 Forced ventilated motors Motor m540 P 90 L4 100 M4 112 M4 132 M4 160 M4 180 M4 100 L4 132 L4 160 L4 180 L4 Without feedback brake L mm 85 0 81 5 81 0...

Страница 79: ...ange m kg 75 0 71 0 116 0 Foot m kg 8 0 Torque plate Housing foot m kg 15 0 25 0 64 0 Shaft cover Shrink disc cover m kg 0 5 0 6 0 9 Hollow shaft cover hoseproof m kg 0 5 0 6 0 9 Motors Motor m540 P 9...

Страница 80: ...haft mounted gearboxes among other things Included rubber buffers ensure low stress installation and absorb any slight impacts The torque plates are available for being installed at the existing foot...

Страница 81: ...er protects the hollow shaft from objects falling in It is sealed by a flat gasket between cover and housing Thus the hollow shaft is protected from dust and water jets on this side Shrink disc cover...

Страница 82: ...Hollow shaft cover hoseproof Product Dimensions k11 mm g500 B8000 250 g500 B13000 313 g500 B20000 372 Product extensions Shaft covers 82...

Страница 83: ...cy Mains voltage Mains voltage range Circuit Hz V V 50 400 380 420 Y 230 220 240 60 460 440 480 Y The motors are rated to the specified line voltage range According to DIN EN 60034 the motors function...

Страница 84: ...brake Terminal box KK6 KK6 KK6 KK6 KK6 KK6 KK6 KK6 KK6 Product extension feedback Terminal box KK7 KK7 KK7 KK7 KK7 KK7 KK7 KK6 KK6 Product extension brake feedback Terminal box KK7 KK7 KK7 KK7 KK7 KK...

Страница 85: ...4 237 297 Terminal box g1 mm 126 166 177 202 237 237 m1 mm 79 0 112 112 130 145 145 n2 mm 93 0 135 135 135 175 175 P1 mm M20x1 5 M32x1 5 M32x1 5 M32x1 5 M40x1 5 M40x1 5 P2 mm M25x1 5 M32x1 5 M32x1 5 M...

Страница 86: ...105 105 105 105 105 105 P6 mm 1x M16x1 5 1x M16x1 5 1x M16x1 5 1x M16x1 5 1x M16x1 5 1x M16x1 5 Motor m540 P P180 M4 P180 L4 P200 M4 P225 M4 P225 L4 P250 M4 Gearbox g500 B8000 x5 mm 316 346 399 415 4...

Страница 87: ...7 n3 mm 105 105 105 105 105 105 P6 mm 1x M16x1 5 1x M16x1 5 1x M16x1 5 1x M16x1 5 1x M16x1 5 1x M16x1 5 Motor m540 P P180 M4 P180 L4 P200 M4 P225 M4 P225 L4 P250 M4 Gearbox g500 B8000 x5 mm 316 346 39...

Страница 88: ...ctor is only available for motors with the Y connection method Motor m540 P 90 L4 100 M4 112 M4 132 M4 160 M4 180 M4 200 M4 225 M4 250 M4 100 L4 132 L4 160 L4 180 L4 225 L4 HAN 10E connector Connectio...

Страница 89: ...205 227 227 219 g500 B13000 x5 mm 226 226 217 Terminal box g4 mm 154 171 171 182 x2 mm 46 46 46 46 m5 mm 123 135 135 135 n5 mm 120 135 135 135 k4 mm 32 32 32 32 m2 mm 95 95 95 95 n3 mm 105 105 105 10...

Страница 90: ...n of the terminal box Shown here T L R or B If required the terminal box can be rotated step by step by 90 after loosening the screws in the terminal box Power connection Bridge arrangement Y connecti...

Страница 91: ...Zero track RS485 0 0 Zero track inverse RS485 Connection of temperature monitoring Terminal box temperature monitoring Contact Name Meaning TB1 Temperature monitoring TCO TB2 1TP1 PTC150 thermistor 2...

Страница 92: ...or is only suitable for motors with the connection method Y HAN 10E connector assignment 1 2 3 4 5 6 7 8 9 10 Bridge arrangement in the HAN 10E mating connector Contact Name Meaning 6 7 8 Y Connection...

Страница 93: ...h before the rectifier AC voltage switching as well as after the rectifier DC voltage switching The choice of control system influences the engagement time of the armature plate inter alia AC switchin...

Страница 94: ...m a high speed and in the event of emergency stops the braking torque is significantly reduced Permissible friction energy 18 16 14 10 08 06 12 1 10 100 1000 10000 10 100 1000 10000 100000 1000000 S h...

Страница 95: ...x 106 Friction lining Low wear Options Manual release UL CSA approved Braking torques An application brake with several braking torques is available for every motor frame size for an optimum adjustmen...

Страница 96: ...namic braking torque Min dynamic braking torque tolerance 25 25 25 25 25 25 25 25 25 25 Max dynamic braking torque tolerance 35 35 35 35 35 35 35 35 35 35 100 rpm Nm 4 0 4 0 8 0 8 0 8 0 8 0 16 16 20 2...

Страница 97: ...40 38 38 60 60 Min static braking torque tolerance 25 25 25 25 25 25 25 25 25 25 Max static braking torque tolerance 35 35 35 35 35 35 35 35 35 35 Dynamic braking torque Min dynamic braking torque tol...

Страница 98: ...80 80 150 150 Min static braking torque tolerance 25 25 25 25 25 25 25 25 25 25 Max static braking torque tolerance 35 35 35 35 35 35 35 35 35 35 Dynamic braking torque Min dynamic braking torque tole...

Страница 99: ...Moment of inertia kgcm 73 73 73 73 73 73 200 200 Braking torque is static Nm 145 145 260 260 315 315 Min static braking torque tolerance 25 25 25 25 25 25 Max static braking torque tolerance 35 35 35...

Страница 100: ...gagement time t1 Direct connection without rectifier ms 180 165 150 Half wave or bridge rectifier ms 180 165 150 Friction energy QBW Direct connection without rectifier MJ 4680 2322 3489 Half wave or...

Страница 101: ...1 g500 B13000 k5 mm 509 539 594 604 672 673 732 733 754 754 g500 B20000 k5 mm 495 525 594 604 657 658 717 718 Brake k mm 74 74 74 103 103 69 103 69 69 65 h5 mm 319 319 319 445 445 330 445 330 330 377...

Страница 102: ...230 230 400 230 230 400 230 230 400 Rated power Prated kW 0 065 0 091 0 091 0 075 0 091 0 091 0 094 0 1 0 1 Rated current Irated A 0 29 0 38 0 22 0 3 0 37 0 22 0 37 0 35 0 2 Motor series m540 P Size 1...

Страница 103: ...Widerstands nderung Operating temperature C 155 Min operating temperature tolerance C 5 Max operating temperature tolerance C 5 Temperature C 20 Rated resistance 155 C 1330 140 C 550 20 C 100 Motor m...

Страница 104: ...featherkey V Hollow shaft with keyway H Hollow shaft with shrink disc S Housing type Foot mounting centering A Foot mounting B With centering C Threaded pitch circle D Flange mounting Without flange R...

Страница 105: ...e 090 100 112 132 160 180 200 225 250 Overall length Medium M Long L Number of poles 4 pole 04 Protection class IP55 5 IP65 6 Cooling Self ventilation E Forced ventilation F Brake Without 0 Spring app...

Страница 106: ...18 7 400 V Irated Y A 3 15 4 40 5 90 7 90 10 8 Starting current Ia A 22 7 37 0 49 0 56 1 92 9 Rated torque Mrated Nm 9 91 14 3 19 6 26 2 35 7 Starting torque Ma Nm 26 8 45 8 49 0 62 9 104 Stalling to...

Страница 107: ...100 Prated 0 904 0 914 0 921 0 926 0 930 Moment of inertia J kgcm 460 830 990 1300 1400 Weight m kg 57 0 73 0 90 0 165 170 Motor m540 P 200 M4 225 M4 225 L4 250 M4 Rated power Prated kW 30 37 45 55 R...

Страница 108: ...895 0 917 Moment of inertia J kgcm 49 0 140 140 170 340 Weight m kg 15 0 29 0 29 0 29 0 57 0 Motor m540 P 132 L4 160 M4 160 L4 180 M4 180 L4 Rated power Prated kW 7 5 11 15 18 5 22 Rated speed nrated...

Страница 109: ...0 71 0 84 0 Starting current Ia A 389 435 511 638 Rated torque Mrated Nm 161 198 241 294 Starting torque Ma Nm 483 555 699 823 Stalling torque Mb Nm 564 595 723 941 Power factor cos 0 83 0 85 0 84 0...

Страница 110: ...0 920 Moment of inertia J kgcm 49 0 140 140 170 340 Weight m kg 15 0 29 0 29 0 29 0 57 0 Motor m540 P 132 L4 160 M4 160 L4 180 M4 180 L4 Rated power Prated kW 13 1 19 2 26 3 32 2 38 5 Rated speed nrat...

Страница 111: ...ed voltage Delta Urated V 400 400 400 400 Rated current 400 V Irated A 98 4 119 143 154 Rated torque Mrated Nm 195 239 291 320 Power factor cos 0 83 0 85 0 86 0 86 Efficiency at 50 Prated 0 928 0 916...

Страница 112: ...emperature C 20 40 Maximum operating temperature C 155 Potentially explosive atmospheres No operation in explosive atmospheres Rated efficiency at full load N 89 5 88 6 89 6 91 7 90 4 91 7 91 4 92 4 E...

Страница 113: ...ally explosive atmospheres No operation in explosive atmospheres Rated efficiency at full load N 93 9 94 5 94 2 95 94 6 95 4 Efficiency at 75 rated load 94 5 94 7 94 9 95 3 95 1 95 6 Efficiency at 50...

Страница 114: ...ded exposure of substances to humans animals and the environment is excluded Lenze products are industrial electrical and electronic products and are disposed of professionally Both the mechanical and...

Страница 115: ...energy efficiency requirements in the USA and Canada C ULUS UL certificate for products tested according to US and Canada standards C URUS UL certificate for components tested according to US and Cana...

Страница 116: ...tL tB Sequence of identical duty cycles comprising operation with a constant load and subsequent standstill Start up and braking processes do not have an impact on the winding temperature The steady s...

Страница 117: ...ction against vertically dripping water dripping water 2 Protection against medium sized foreign particles d 12 mm keeping away fingers or the like 2 Protection against diagonally falling water drippi...

Страница 118: ......

Страница 119: ......

Страница 120: ...04 2021 1 0 www Lenze com...