21
Appendix
21.1
Parameter attribute list
The parameter attribute list in particular contains some information required for reading and
writing parameters via network.
•
The parameter attribute list contains all parameters of the inverter.
•
The parameter attribute list is sorted by addresses (index:subindex) in ascending order.
How to read the parameter attribute list:
Column
Meaning
Address
Address of the parameter in the object directory. Format: Index:Subindex
Designation
Parameter name
Default setting Default setting of the parameter
Data type
Data type of the parameter:
I8
INTEGER_8
1 byte, with sign
I16
INTEGER_16
2 bytes with sign
I32
INTEGER_32
4 bytes with sign
I64
INTEGER_64
8 bytes with sign
U8
UNSIGNED_8
1 byte without sign
U16
UNSIGNED_16
2 bytes without sign
U32
UNSIGNED_32
4 bytes without sign
U64
UNSIGNED_64
8 bytes without sign
STRING[xx]
VISIBLE_STRING ASCII string (with character length xx)
OCTET[xx]
OCTET_STRING
OCTET string (with xx bytes)
IDX
4 bytes without sign. Is used specially for addressing parameters.
Factor
Factor for data transmission via network, depending on the number of decimal positions:
1
No decimal positions
10
1 decimal position
100
2 decimal positions
1000
3 decimal positions
10000
4 decimal positions
A
Attributes (combinations of several attributes also possible):
C
Setting can only be changed if the inverter is inhibited.
E
Value is displayed as IP address.
H
Value is displayed in hexadecimal form.
I
Parameter is not displayed.
C
Parameter is not displayed.
O
Parameter can be recorded with the oscilloscope function.
P
Setting is saved in the memory module.
X
Parameter is not displayed in the engineering tools.
M
Mapping:
r
Receive mapping permissible.
t
Transmit mapping permissible.
rt
Receive and transmit mapping permissible.
-
Mapping not permissible.
Parameter attribute list (short overview of all parameter indexes)
Address
Designation
Default setting
Data type
Factor A
M
Device type
- (Read only)
U32
1
X
EtherCAT error register
- (Read only)
U8
1
X
●
Manufacturer device name
- (Read only)
STRING[50]
X
Manufacturer hardware version
- (Read only)
STRING[50]
X
Manufacturer software version
- (Read only)
STRING[50]
X
Identity object : Vendor ID
- (Read only)
U32
1
X
Identity object : Product ID
- (Read only)
U32
X
* Default setting depending on the size.
Appendix
462
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......