![Lenze i950 Series Скачать руководство пользователя страница 460](http://html.mh-extra.com/html/lenze/i950-series/i950-series_manual_1882145460.webp)
20.3
3-phase mains connection 480 V
20.3.1
Rated data
Inverters
I95AE155F
I95AE175F
I95AE222F
I95AE240F
I95AE275F
I95AE311F
I95AE315F
Rated power
kW
0.55
0.75
2.2
4
7.5
11
15
Rated power
hp
0.75
1
3
5
10
15
20
Mains voltage range
3/PE AC 340 V ... 528 V, 45 Hz ... 65 Hz
Output voltage
3 AC 0-480 V
Rated mains current
without mains choke
A
2.1
2.8
6.5
10.5
16.6
23.7
-
with mains choke
A
1.7
2.2
4.4
7.5
13.1
18.6
24
Apparent output power
kVA
1.2
1.6
3.8
6.4
11
16
22
Rated output current
2 kHz
A
1.6
2.1
4.8
8.2
14
21
27
4 kHz
A
1.6
2.1
4.8
8.2
14
21
27
8 kHz
A
1.6
2.1
4.8
6.2
14
21
19.8
16 kHz
A
1.1
1.4
2.2
2.5
7.8
7.8
7.2
Power loss
2 kHz
W
38
44
76
116
186
256
342
4 kHz
W
39
46
80
122
197
272
363
8 kHz
W
45
54
99
154
252
351
471
16 kHz
W
45
54
99
154
252
351
471
at inverter disable
W
20
20
20
20
20
20
20
Cyclic mains switching
3 times per minute
Max. motor cable length shielded
Category C2 (2 kHz, 4 kHz, 8
kHz)
m
20
20
20
20
20
20
20
Category C3 (2 kHz, 4 kHz, 8
kHz)
m
35
35
35
35
35
35
35
without EMC category
m
50
50
50
50
100
100
100
Weight
kg
1.6
1.6
1.6
1.6
3.9
3.9
3.9
Weight
lb
3.5
3.5
3.5
3.5
8.6
8.6
8.6
Technical data
3-phase mains connection 480 V
Rated data
460
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......