![Lenze i950 Series Скачать руководство пользователя страница 456](http://html.mh-extra.com/html/lenze/i950-series/i950-series_manual_1882145456.webp)
20
Technical data
20.1
Standards and operating conditions
20.1.1
Conformities/approvals
Conformity
CE
2006/42/EC
Machinery Directive
2014/30/EU
EMC Directive (reference: CE-typical drive system)
RoHS
2011/65/EU
Restrictions for the use of specific hazardous materials in electric
and electronic devices
Approval
UL
UL 61800-5-1
for USA and Canada (requirements of the CSA 22.2 No. 274)
File No. E132659
up to 75 kW
20.1.2
Protection of persons and device protection
Enclosure
IP20
EN 60529
Information applies to the mounted and ready-for-use state. It
does not apply to the wire range of the terminals
NEMA 250
only protection against accidental contact acc. to type 1
Open type
Only in UL-approved systems
Insulation resistance
Overvoltage category III
EN 61800-5-1
0 … 2000 m a.m.s.l.
Overvoltage category II
EN 61800-5-1
above 2000 m a.m.s.l.
Control circuit isolation
Safe mains isolation by double/reinforced insula-
tion
EN 61800-5-1
Protective measures against
Short circuit
Earth fault
Earth fault strength depends on the operating status
Motor overtemperature
PTC or thermal contact, I²xt monitoring
Overvoltage
Motor stalling
Leakage current
> 3.5 mA AC, > 10 mA DC
EN 61800-5-1
Observe regulations and safety instructions!
Starting current
≤ 3 x rated mains current
20.1.3
EMC data
Actuation on public supply systems
Implement measures to limit the radio interfer-
ence to be expected:
The machine or plant manufacturer is responsible for compliance
with the requirements for the machine/plant!
< 1 kW: with mains choke
EN 61000-3-2
> 1 kW at mains current ≤ 16 A: without addi-
tional measures
Mains current > 16 A: with mains choke or
mains filter, with dimensioning for rated
power.
EN 61000-3-12
Noise emission
Category C2
EN 61800-3
see rated data
Category C3
EN 61800-3
see rated data
Noise immunity
Meets requirement in compliance with
EN 61800-3
Technical data
EMC data
456
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......