Parameter
Address
Name / setting range / [default setting]
Info
0x28B8:001
SDI: Source SD-In: SDIpos: Source SD-In
•
Read only
0 Deactivated
1 SD-In1
2 SD-In2
3 SD-In3
4 SD-In4
0x28B8:002
SDI: Source SD-In: SDIneg: Source SD-In
•
Read only
0 Deactivated
1 SD-In1
2 SD-In2
3 SD-In3
4 SD-In4
0x28B9:001
SDI: Source S-Bus: SDIpos: Source S-Bus
•
Read only
0 Deactivated
1 Activated
0x28B9:002
SDI: Source S-Bus: SDIneg: Source S-Bus
•
Read only
0 Deactivated
1 Activated
0x28BA:001
SDI: SDI: Monitoring normal operation
•
Read only
0 Both directions enabled
1 Positive direction enabled
2 Negative direction enabled
0x28BA:002
SDI: SDI: Delay time
•
Read only: x ms
0x28BA:003
SDI: SDI: Tolerance threshold
•
Read only
0x28BA:004
SDI: SDI: Error reaction
•
Read only
0 STO
1 SS1
2 SS2
0x28BA:005
SDI: SDI: Maximal change of Position
•
Read only
0x28BB:001
SDI monitored: Output: SDIpos monitored: Output
•
Read only
0 Deactivated
1 SD-Out1 positive logic
2 SD-Out1 negative logic
0x28BB:002
SDI monitored: Output: SDIneg monitored: Output
•
Read only
0 Deactivated
1 SD-Out1 positive logic
2 SD-Out1 negative logic
Safety functions
Safe Direction (SDI)
421
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......