13.10
Frequency and speed limitations
By limiting the maximum output frequency to ± 599 Hz, the devices are not sub-
ject to the export restrictions of the "EC-Dual-Use Regulation" (EC 428/2009).
This applies to devices supplied from the middle of the year 2015. For certain
applications, the supply of devices with the current maximum output frequency
of ± 1999 Hz. If required, get in touch with your Lenze contact person.
Output frequency
The output frequency of the i700 servo inverter is limited to a maximum value, the amount of
which corresponds to the lower of the two following values:
chop
lim
lim
max_ Geräte
f
f
oder
f
f
8
=
=
lim
f
Maximum output frequency
f
chop
Switching frequency
f
max_device
Maximum device output frequency
, depending on the device type ± 599
Hz or ± 1999 Hz
Due to the restrictions by the "dual use regulation" (EC 428/2009), values higher than + 599
Hz to + 1000 Hz or - 599 Hz to - 1000 Hz do not increase the output frequency. Please observe
the deadband occurring in this case.
Speed setpoint
If servo control is used, the speed setpoint is limited depending on the number of motor pole
pairs:
lim
lim
f
n
zp
=
n
lim
Speed limit value
f
lim
Maximum output frequency
zp
Number of motor pole pairs
•
If the speed setpoint is limited, bit 1 ("Speed: Setpoint 1 limited") or bit 5 ("Speed: Set-
point 2 limited") is set in the Lenze status word
.
•
The behaviour corresponds to the behaviour which is shown when the set maximum
speed
is reached.
•
The sequence is: limit the speed to
first, then limit it to the speed limit value n
lim
.
Frequency setpoint
If V/f characteristic control is used, the frequency setpoint is limited in addition to the speed
setpoint.
•
If the frequency setpoint is limited, bit 10 ("Output frequency limited") is set in the Lenze
status word
Configuring the motor control
Frequency and speed limitations
300
Содержание i950 Series
Страница 1: ...Inverters i950 servo inverters Commissioning EN ...
Страница 2: ......
Страница 312: ...15 Configure engineering port The given path leads you to the engineering port Configure engineering port 312 ...
Страница 397: ...19 Safety functions Supported safety functions for Basic Safety STO 4Safe Torque Off STO 398 Safety functions 397 ...
Страница 497: ......
Страница 498: ......
Страница 499: ......