12.4.2
Pole position identification (PPI) 360°
DANGER!
Mechanical damage of the motor caused by hanging loads!
The motor may be permanently damaged.
▶
The motor must not be braked or blocked during the pole position identification. Thus, this
function must not be used for hanging loads!
NOTICE
Thermal overload of the motor!
The motor may be permanently damaged.
▶
Before executing the pole position identification, check that the following monitoring sys-
tems are parameterised correctly.
▶
Motor overload monitoring (i²*t)
▶
NOTICE
▶
Please observe the following:
Synchronous motor: Pole position identification (PPI)
Functional description
0°
α
22.5°
45°
45°
67.5°
90°
112.5°
135°
157.5°
180°
202.5°
247.5° 270° 292.5°
337.5°
β
0° , d
α
q β
d
q
225°
315°
Configuring the feedback system
Synchronous motor: Pole position identification (PPI)
Pole position identification (PPI) 360°