3-phase mains connection 400 V
Rated data
The output currents apply to these operating conditions:
•
At switching frequency 2 kHz or 4 kHz: Ambient temperature max. 45 °C (113 °F).
•
At switching frequency 8 kHz, 12 kHz or 16 kHz: Ambient temperature max. 40 °C (104 °F).
Inverter
I51AP
175F
211F
215F
222F
230F
240F
255F
Rated power
P
rated
kW
0.75
1.1
1.5
2.2
3
4
5.5
Rated power
P
rated
HP
1
1.5
2
3
4
5
7.5
Mains voltage range
3/PE AC 340 V ... 528 V, 45 Hz ... 65 Hz
Output voltage
3 AC 0 - 400/480 V
Rated mains current
without mains choke
A
3.3
4.4
5.4
7.8
9.6
12.5
17.2
with mains choke
A
-
Apparent output power
kVA
1.6
2.1
2.6
3.8
4.9
6.4
8.7
Rated output current
2 kHz
A
2.4
3.2
3.9
5.6
7.3
9.5
13
4 kHz
A
2.4
3.2
3.9
5.6
7.3
9.5
13
8 kHz
A
2.4
3.2
3.9
5.6
7.3
9.5
13
12 kHz
A
1.9
2.9
3.5
5
5.8
7.6
10.4
16 kHz
A
1.4
2.1
2.6
3.7
4.9
6.3
8.7
Power loss
2 kHz
W
30
38
45
62
79
102
137
4 kHz
W
32
40
48
66
84
108
145
8 kHz
W
40
51
61
85
109
140
189
12 kHz
W
38
54
65
91
104
133
180
16 kHz
W
35
49
58
81
104
133
180
Cyclic mains switching
3 times per minute
Brake chopper
Max. output current
-
Min. Brake resistor
-
Max. shielded motor cable
length
without EMC category
m
30
50
Category C1 (2 kHz, 4 kHz,
8kHz)
m
-
Category C2 (2 kHz, 4 kHz, 8
kHz)
m
-
Category C3 (2 kHz, 4 kHz, 8
kHz)
m
-
Max. Unshielded motor cable
length
without EMC category
m
60
80
100
Technical data
3-phase mains connection 400 V
Rated data
54
Содержание i510 protec
Страница 2: ......