9300 Servo PLC
System blocks
2.12
MCTRL_MotorControl
2-50
L
ServoPLC EN 2.0
2.12.14
Feedback system
Use the following codes to configure the feedback system for the position controller and speed
controller:
Code
LCD
Possible settings
IMPORTANT
o
Lenze
Selection
[C0420] Encoder const
512
Encoder: Constant for encoder input
X8
1
{1 inc/rev}
8192
[C0490] Feedback pos
0
Feedback system for the speed con-
troller
•
C0490 = 0, 1, 2 can be mixed
with
C0495 = 0, 1, 2.
•
C0490 = 3, 4 sets C0495 to the
same value.
0
Resolver at X7
1
Encoder TTL at X8
2
sin/cos encoder at X8
3
Absolute value encoder ST at X8
4
Absolute value encoder MT at X8
[C0495] Feedback n
Feedback system for the speed con-
troller
•
C0495 = 0, 1, 2 can be mixed
with
C0490 = 0, 1, 2.
•
C0495 = 3, 4 sets C0490 to the
same value.
0
Resolver at X7
1
Encoder TTL at X8
2
sin/cos encoder at X8
3
Absolute value encoder ST (single turn) at X8
4
Absolute value encoder MT (multi turn) at X8
2.12.15
Touch probe (TP)
Process: The current angle value (digital frequency input value) is stored by a quick interrupt in the
operating system when a signal change occurs at the TP activating input (e.g. X5/E4).
MCTRL_dnActIncLastScan_p
TP
j
Fig. 2-25
Function diagram of a TP
Time-equidistant start of an interval-task
ϕ
Phase-angle signal
efesotomasyon.com - Lenze
Show/Hide Bookmarks