![Lenze Global Drive 9300 Servo PLC Series Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/lenze/global-drive-9300-servo-plc-series/global-drive-9300-servo-plc-series_manual_1882356031.webp)
9300 Servo PLC
System blocks
2.5
ANALOG1_IO
2-17
L
ServoPLC EN 2.0
2.5.2
Outputs_ANALOG1
Analog output 1 (module number: 11)
You can use this SB as a monitor output. Internal analog signals can be output via terminal X6/62 as
voltage signals, and used, for example, as display or setpoints for following drives.
Outputs_ANALOG1
AOUT1_nOut_a
C0434/1
X6
62
Fig. 2-9
Outputs_ANALOG1
VariableName
DataType
SignalType
Address
DIS
DIS format
Note
AOUT1_nOut_a
Integer
analog
%QW11.0
C0434/1
dec [%]
Analog output 1
Terminal assignment
Terminal
Use
Data
X6/62
Analog output 1 (monitor 1)
Level:
Resolution:
Normalisation:
-10 V ... +10 V (max. 2 mA)
20 mV (9 bit + sign)
±
10 V
≡ ±
16384
≡ ±
100 %
X6/7
Internal ground, GND
-
efesotomasyon.com - Lenze