Implemented CIP™ objects
General CIP objects
112
Lenze · Decentralised frequency inverter 8400 motec (EtherNet/IP™ option) · EDS84DMOTEIP EN 3.0 - 02/2019
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Instance attribute "Status" (attribute 5)
Supported service codes
Bits
Name
Description
0
Owned
The state ’1’ indicates that the device (or an object within the device) has
an owner. Within a master/slave model, the state ’1’ indicates that the
"predefined master/slave connection set" is assigned to a master.
Outside the master/slave model, it means "TBD".
1
-
Reserved (0)
2
Configured
The state ’1’ indicates that the activities the device application carries
out differ from the "out of box" standard configuration. This should not
comprise the configuration of communication.
3
-
Reserved (0)
4 ... 7
Extended Device Status
• 0000: Status is "self-testing" or unknown
• 0001: Firmware update is being carried out
• 0010: At least one faulty I/O connection
• 0011: No I/O connections available
• 0100: Non-volatile configuration is faulty
• 0101: "Major fault" (bit 10 or 11 is ’1’)
• 0110: At least one I/O connection is in the "run mode"
• 0111: At least one I/O connection is available, all are in the "idle
mode"
• 1000: Reserved
• 1001: Reserved
• 1010 ... 1111: Reserved / manufacturer-specific
8
Minor Recoverable Fault
The state ’1’ indicates that a "Minor Recoverable Fault" has occurred.
9
Minor Unrecoverable Fault
The state ’1’ indicates that a "Minor Unrecoverable Fault" has occurred.
10
Major Recoverable Fault
The state ’1’ indicates that a "Major Recoverable Fault" has occurred.
11
Major Unrecoverable Fault
The state ’1’ indicates that a "Major Unrecoverable Fault" has occurred.
12 ... 15
Extended Device Status 2
Reserved (0) / manufacturer-specific
Service code
[hex]
Name
Description
0x01
Get_Attributes_All
Outputs a list of the attributes and the attribute's values for
a certain object.
0x05
Reset
These reset service types are supported:
• 0: Mains switching (power off/on) is simulated.
• 1: The parameters of the device are reset to the Lenze
setting and mains switching (power off/on) is simulated.
0x0E
Get_Attribute_Single
Outputs the value of a certain attribute.