Lenze EPM-H410 Скачать руководство пользователя страница 89

Operation

Data input

6

 89

EDBPM−H410   DE/EN/FR   4.1

Example

Press keys ...

You want to ...

J

change a recipe name value.

1. Change to the parameter level

(see D).

F

eld 1

ON

F

eld

2

-

19

34

F

eld

3

1

23

.

467

F

eld

4

1C

3F

F

eld

5

ROJE

K

T1

P

F

eld 1

ON

F

eld

2

-

19

34

F

eld

3

1

23

.

467

F

eld

4

1C

3F

F

eld

5

R

ROJE

K

T1

F

eld 1

ON

F

eld

2

-

19

34

F

eld

3

1

23

.

467

F

eld

4

1C

3F

F

eld

5

REZEPT

2

2. Select the desired character.

or

3. Change the character (e.g. R").
4. Repeat step 3. until the new value is

entered (e.g. RECIPE").

P Q R

5

3x

5. Enter a digit (e.g. 2").

G H I

2

4x

6. Confirm the input.

– The cursor changes to the menu

level.

Enter

Содержание EPM-H410

Страница 1: ...ing Instructions Instructions de mise en service F1 F12 F23 Alarm Help Info shift Battery Power Space V W X 7 M N O 4 A B C 0 D E F 1 G H I 2 J K L 3 Enter Spare Clr Esc P Q R 5 S T U 6 Y Z 8 9 F2 F13 F24 F3 F14 F4 F15 F5 F16 F6 F17 F7 F18 F8 F19 F9 F20 F10 F21 F11 F22 Bus Error Ack All Ack PgDN PgUp ...

Страница 2: ...achten Sie die enthaltenen Sicherheitshinweise Please read these instructions before you start working Follow the enclosed safety instructions Veuillez lire attentivement cette documentation avant toute action Les consignes de sécurité doivent impérativement être respectées ...

Страница 3: ...C 0 D E F 1 G H I 2 J K L 3 Enter Spare Clr Esc P Q R 5 S T U 6 Y Z 8 9 F2 F13 F24 F3 F14 F4 F15 F5 F16 F6 F17 F7 F18 F8 F19 F9 F20 F10 F21 F11 F22 Bus Error Ack All Ack PgUp PgDN 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V MSP fuse 800 mA back up card 0 1 h410_018 ...

Страница 4: ...EDBPM H410 DE EN FR 4 1 Legende zur Übersicht Pos Beschreibung Funktion Klemmenleiste 4 polig DC Spannungsversorgung 24 V Klemmenleiste 5 polig Systembus CAN DB25 Buchse Serieller Port MSP für PC oder SPS ...

Страница 5: ... 5 EDBPM H410 DE EN FR 4 1 Diese Dokumentation ist gültig für die Bedieneinheit EPM H410 ab der Typenschildbezeichnung Typ EPM H410 1B 10 Produktreihe EPM Bedieneinheit Hardwarestand Softwarestand ...

Страница 6: ...Aktualisierung 13261360 4 0 06 2009 TD23 Umfirmierung 00457282 3 0 08 2002 TD23 Umfirmierung 00418423 2 0 08 2001 TD23 Komplette Überarbeitung zur Serie 00414159 1 0 03 2000 TD23 Erstauflage zum Feldtest 0Abb 0Tab 0 Tipp Informationen und Hilfsmittel rund um die Lenze Produkte finden Sie im Download Bereich unter http www Lenze com ...

Страница 7: ... 18 3 MechanischeInstallation 19 3 1 Bedieneinheit beschriften 19 3 2 Bedieneinheit einbauen 21 4 ElektrischeInstallation 22 4 1 Versorgungsspannung anschließen 22 4 2 Systembus CAN verdrahten 23 4 3 Memory Card ein ausbauen 25 4 3 1 Memory Card 4 MB 25 5 Inbetriebnahme 28 5 1 Erstes Einschalten 28 5 2 Projekt in die Bedieneinheit übertragen 29 5 2 1 Bedieneinheit und PC verbinden 29 5 2 2 Projekt...

Страница 8: ...ationsmeldungaufrufen 40 6 4 Alarmmeldungen aufrufen 41 6 5 Hilfemeldung aufrufen 43 6 6 Daten sichern auf der Memory Card 44 7 Fehlersucheund Störungsbeseitigung 45 7 1 Störungsmeldungen 45 8 Wartung 46 8 1 Interne Batterie wechseln 46 9 Anhang 49 9 1 Chemikalienbeständigkeit 49 9 2 Stichwortverzeichnis 51 ...

Страница 9: ...ngaben und Hinweise beachten ƒ Die Betriebsanleitung muss stets komplett und in einwandfrei lesbarem Zustand sein 1 2 Verwendete Begriffe Begriff Im folgenden Text verwendet für Antriebsregler Lenze Frequenzumrichter 8200 vector und 9300 vector Lenze Servo Umrichter 9300 und 9400 HMI Human Machine Interface 1 3 Lieferumfang Lieferumfang Wichtig l 1 Bedieneinheit EPM H410 ohne Batterie l 1 Betriebs...

Страница 10: ...s auf eine unmittelbar drohende Gefahr die den Tod oder schwere Verletzungen zur Folge haben kann wenn nicht die entsprechenden Maßnahmen getroffen werden Gefahr Gefahr von Personenschäden durch eine allgemeine Gefahrenquelle Hinweis auf eine unmittelbar drohende Gefahr die den Tod oder schwere Verletzungen zur Folge haben kann wenn nicht die entsprechenden Maßnahmen getroffen werden Stop Gefahr v...

Страница 11: ...d Geräteschutz Schutzart IP65 frontseitig EMV Angewandte Normen zu Grenzwerten EN 61000 6 4 2007 Störaussendung Nutzungsbeschränkung Die Einhal tung der Schutzanforderungen in Wohngebieten ist nicht gewährleistet EN 61000 6 2 2005 Störfestigkeit Nutzungsbeschränkung Die Einhal tung der Schutzanforderungen in Wohngebieten ist nicht gewährleistet Einsatzbedingungen Umgebungsbedingungen Klimatisch La...

Страница 12: ...htung LED Elektrischer An schluss DC Spannungsversorgung DC 24 V 18 32 V Leistungsaufnahme 11 W bei DC 24 V Absicherung Feinsicherung Æ5 20 mm 800 mA F Netzwerk Systembus CAN Protokoll CANopen CAL basierendes Kommunikationsprofil DS301 Kommunikationsmedium DIN ISO 11898 Netzwerk Topologie Linie beidseitig abgeschlossen mit 120 W Systembus Teilnehmer Master oder Slave max Anzahl Teilnehmer 63 Baudr...

Страница 13: ... Trends Speicher Trends Erfassungen Automatische Operationen Anzahl 16 Backup Wiederherstellen Funktion vorhanden Balkengrafik Funktion vorhanden Befehle Alarmregister drucken Funktion vorhanden Anzeigen Alarmregister Bedienseite Blattvorschub aufdemDruk ker Die generelle Seitennummer auf Null setzen Hardcopy Hilfe der Seite Passwort ändern Passwort Login Passwort Logout Pipeline laufen lassen Pro...

Страница 14: ...N Funktion vorhanden EINGEBEN ODER UND XOR ZUFÜGEN Druck Funktion vorhanden Druckseiten Total Felder pro Seite Anzahl 1024 128 Dynamische Bitmaps mit Bitgruppen Struktur Ein zelbit Struktur oder Wert Struktur Anzahl 1024 1 Dynamische Texte mit Bitgruppen Struktur Einzel bit Struktur oder Wert Struktur Anzahl 1024 1 E Tasten Funktion vorhanden Einer Sequenz zugeordnete LEDs Funktion vorhanden Etike...

Страница 15: ...ro Kopf Fußzeile 128 128 Kreise Funktion vorhanden Linien Funktion vorhanden Lokale Konfiguration E Tasten Funktion vorhanden Lokale Konfiguration F Tasten Funktion vorhanden Makrofeld Anzahl je Seite 16 Makros Total Befehle Makro Anzahl 1024 16 Meldungs Hilfen Anzahl 1024 Meldungsfeld Funktion vorhanden Multilinguale Texte Anzahl Sprachen 8 Passwort Ebenen Anzahl 10 Programmierbare Fonts Funktion...

Страница 16: ...zahl 2 2 Variablen Grenzwerte und lineare Kor rektur Variablen Anzahl je Seite 80 Bewegungsvariablen be wegliches symbolisches Feld Schwellenvariablen Numerische Gleitpunkt Va riablen Numerische Variablen DEC HEX BIN BCD String Variablen ASCII Wochentagsfeld Funktion vorhanden Öffentliche Variablen für ESANET Netzwerk Anzahl Bytes total 128 1024 1 von der Projektgröße begrenzter Richtwert 2 von de...

Страница 17: ...ellenbeschreibung 1 14 h410_013 Abb 2 1 MSP DB25 Buchse Pin Signal 1 n c 2 Tx RS232 OUT 3 Rx RS232 IN 4 RTS RS232 OUT 5 CTS RS232 IN 6 n c 7 Signal GND 8 n c 9 16 Signale werden nicht ausgewertet 17 n c 18 Signal wird nicht ausgewertet 19 21 n c 22 25 Signale werden nicht ausgewertet n c Nicht angeschlossen ...

Страница 18: ... Spare Clr Esc P Q R 5 S T U 6 Y Z 8 9 F2 F13 F24 F3 F14 F4 F15 F5 F16 F6 F17 F7 F18 F8 F19 F9 F20 F10 F21 F11 F22 Bus Error Ack All Ack PgUp PgDN h410_001 Abb 2 2 Abmessungen a mm b mm d mm e mm 252 0 196 0 5 0 60 0 2 4 Einbauausschnitt a g g h b Æ k d e e f c h410_002 Abb 2 3 Einbauausschnitt a mm b mm c mm d mm e mm f mm g mm h mm k mm 232 0 178 0 242 0 186 0 29 0 120 0 116 0 5 0 4 5 ...

Страница 19: ... Die Bedieneinheit kann mit auswechselbaren Schildern beschriftet werden ƒ Die Schilder sind nur bei ausgebauter Bedieneinheit zugänglich ƒ Beschriften Sie die Schilder bevor Sie die Bedieneinheit in die Einbautafel montieren 0 0 0 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V MSP fuse 800 mA back up card h410_008 Abb 3 1 Gehäusedeckel abnehmen 1 Schrauben lösen und Gehäusedeckel abnehme...

Страница 20: ...5 Tasten F6 F11 Tasten F12 F16 Tasten F17 F22 So beschriften Sie die Schilder 2 Schild oder aus dem Schlitz ziehen und beschriften 3 Anschließend beschriftetes Schild in den Schlitz schieben 0 0 0 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V MSP fuse 800 mA back up card h410_008 Abb 3 3 Gehäusedeckel schließen 4 Gehäusedeckel aufsetzen Schrauben eindrehen und festziehen ...

Страница 21: ... 3 2 Bedieneinheit einbauen Die Maße für den Einbauausschnitt entnehmen Sie den technischen Daten 18 0 h410_003 1 Bedieneinheit in den Einbauausschnitt schieben 2 1 3 h410_012 2 U Scheiben 6 Stück aufstecken 3 Muttern 6 Stück auf die Gewindebolzen 6 Stück drehen und festziehen ...

Страница 22: ...it nur im spannungslosen Zustand verdrahten 4 1 Versorgungsspannung anschließen 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V INPUT VOLTAGE 18 32 VDC 11 W MSP PE N L1 fuse 800 mA back up card 18 32VDC h410_004 Abb 4 1 Anschluss der Versorgungsspannung Klemmenbelegung Klemme Bezeichnung Erläuterung 1 DC 24 V Versorgungsspannung DC 18 V 32 V 2 DC 0 V GND Versorgungsspannung Bezugspotential...

Страница 23: ...C CG LO HI CG LO CG LO HI CG LO HI HI 120 120 An A2 H410 A1 h410_006 Abb 4 2 Verdrahtung des Systembus CAN A1 Busteilnehmer 1 A2 Busteilnehmer 2 An Busteilnehmer n Anschluss 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V INPUT VOLTAGE 18 32 VDC 11 W MSP CAN GND CAN LO CAN HI fuse 800 mA back up card h410_019 Abb 4 3 Anschluss Systembus CAN ...

Страница 24: ...ential 2 CAN LO Systembus LOW Datenleitung 3 Shield Schirm des Systembus Kabels auflegen 4 CAN HI Systembus HIGH Datenleitung 5 n c Nicht angeschlossen Wir empfehlen CAN Kabel nach ISO 11898 2 zu verwenden CAN Kabel nach ISO 11898 2 Kabeltyp Paarverseilt mit Abschirmung Impedanz 120 W 95 140 W Leitungswiderstand querschnitt Kabellänge 300 m 70 mW m 0 25 0 34 mm2 AWG22 Kabellänge 301 1000 m 40 mW m...

Страница 25: ...t beschädigen können 4 3 1 Memory Card 4 MB ƒ Auf diesen Speicherbaustein können Sie Ihr anwendungsspezifisch konfiguriertes Projekt sichern und archivieren ƒ Sie können den Speicherbaustein mit dem gesicherten Projekt in eine Bedieneinheit gleichen Typs einbauen um das Projekt in diese Bedieneinheit zu übertragen ƒ Die 4 MB Memory Card ist bei Lenze erhältlich unter der Best Nr EPZ H210 Gehäusede...

Страница 26: ...2 1 l Memory Card 4 MB h410_011 Abb 4 5 Memory Card einbauen 1 Speicherbaustein mit dem Etikett sichtbar halten 2 Nase des Speicherbausteins unter die Kante des Sockels schieben 3 4 l Memory Card 4 MB h410_014 Abb 4 6 Memory Card einrasten 3 Speicherbaustein an Pos vorsichtig drücken bis er unter die Klammer einrastet ...

Страница 27: ... Abb 4 7 Memory Card ausbauen 1 Klammer zurückdrücken bis der Speicherbaustein hochspringt 2 Speicherbaustein vorsichtig entnehmen Gehäusedeckel schließen 0 0 0 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V MSP fuse 800 mA back up card h410_008 Abb 4 8 Gehäusedeckel schließen 1 Gehäusedeckel aufsetzen Schrauben eindrehen und festziehen ...

Страница 28: ...halten Für die Inbetriebnahme ist eine vollständige Verdrahtung des Systembus not wendig ÜberprüfenSie vor dem Einschalten der Versorgungsspannung ƒ die gesamte Verdrahtung auf Vollständigkeit und Kurzschluss ƒ ob das Bussystem beim physikalisch ersten und letzten Busteilnehmer abgeschlossen ist ...

Страница 29: ...verbinden Stop Die Verbindung zwischen PC und Bedieneinheit nur bei ausgeschalteten Geräten herstellen l HMI Designer 0 1 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V INPUT VOLTAGE 18 32 VDC 11 W MSP fuse 800 mA back up card h410_005 Abb 5 1 Bedieneinheit und PC verbinden ƒ Download KabelEPZ H110 an der Bedieneinheit auf MSP Schnittstelle und am PC auf COM1 oder COMx stecken ...

Страница 30: ...wählen ob mit dem Laden des Projekts gleichzeitig die Firmware aktualisiert werden soll Die Firmware muss immer beim ersten Download eines Projekts in die Bedieneinheit bzw nach einem Update des Projektierungstool HMI Designer aktualisiert werden Tipp Beispiel Projekte für die Bedieneinheit finden Sie im Projektierungstool HMI Designer unter Datei Öffnen Samples ...

Страница 31: ... drücken Auf dem Display wird folgende Auswahl angezeigt F1 MSP F2 Memory CARD nur wenn die Karte eingebaut ist ENTER EXIT 4 F1 Taste drücken für den Download über die MSP Schnittstelle 5 Wenn auf dem Display die Meldung Waiting for download from MSP erscheint gewünschtes Projekt vom HMI Designer in die Bedieneinheit laden Siehe Handbuch HMI Designer Erste Schritte Während des Download wird PROGRA...

Страница 32: ...t aufgetretene Störung Error Sie möchten Drücken Sie die Tasten Beispiel A den Status der Bedieneinheit abfragen shift 2x Port MSP Driver CAN Lenze M Ver 1 01 Addr VT NO ADDR Error NO ERROR ENTER Set Clock Contrast B die Statusanzeige schließen Clr Esc 5 4 Betriebsanzeigenan der Bedieneinheit Anzeige An Aus Blinkt LED rot Bus Error Kein Kommunikations fehler Kommunikationsfeh ler am System bus CAN...

Страница 33: ...nter B Datum Uhrzeit einstellen 1 Menü SET CLOCK auswählen PgUp oder PgDN SET CONTRAST 04 SET CLOCK Wed 13 09 00 12 50 10 2 Menü anwählen Enter 3 Gewünschtes Feld anwählen oder 12 50 10 13 09 00 4 Wert ändern PgUp oder PgDN 5 Ggf Schritt 3 und 4 wiederholen um weitere Werte zu ändern 6 Eingabe bestätigen Enter C Kontrast am Display einstellen 1 Menü SET CONTRAST auswählen PgUp oder PgDN SET CONTRA...

Страница 34: ...ons und Statusmeldungen verlassen shift Clr Esc Clr Parameter Ebene Stellt während der Datenein gabe den ursprünglichen Wert wieder her PgUp PgUp Pfeil auf Menü Ebene Vorherige Seite anwählen Parameter Ebene Vorherigen dynamischen Text anwählen PgDN PgDn Pfeil ab Menü Ebene Nächste Seite anwählen Parameter Ebene Nächsten dynamischen Text anwählen Pfeil links Menü Ebene Cursor auf das vorherige Fel...

Страница 35: ...orhanden Alarm Alarm Alarmmeldung anzeigen LED blinkt wenn Alarmmeldung vorhanden Alarm Ack Angezeigten Alarm zurücksetzen quittieren shift Alarm All Ack Alle anstehenden Alarme zurücksetzen quittie ren Drucken Taste programmierbar z B um einen Druckvor gang zu starten Handbuch HMI Designer Spare Spare Keine Funktion Hinweis Die Funktionstasten Fx sind über die Software HMI Designer programmierbar...

Страница 36: ...l A ein Menü auswählen F1 F24 B eine Seite anwählen PgUp oder PgDN C den Cursor auf das vorherige oder näch ste Feld stellen oder Feld 1 ON Feld 2 987 Feld 3 123 467 Feld 4 1A3F 6 D in die Parameter Ebene wechseln l Der Cursor stellt sich auf die rechte Ziffer l In einem alphanumerischen oder dy namischen Textfeld stellt sich der Cursor auf das linke Zeichen siehe J oder I Feld 1 ON Feld 2 987 Fel...

Страница 37: ...Feld 2 001 Feld 3 123 467 Feld 4 1A3F 2 5 Geben Sie ggf ein Gleitkomma ein shift Space Feld 1 ON Feld 2 012 Feld 3 123 467 Feld 4 1A3F TIPP Sie können ein Gleitkomma nur einfügen wenn das Feld als Floa ting Point definiert ist siehe Projektie rungstool HMI Designer 6 Wiederholen Sie Schritt 4 bis Sie den Wert vollständig eingegeben haben 7 Geben Sie ggf ein Vorzeichen ein Space Feld 1 ON Feld 2 12...

Страница 38: ...ie eingegebenen Ziffern werden eine Stelle nach links geschoben 5 Wiederholen Sie Schritt 4 bis Sie den Wert vollständig eingegeben haben D E F 1 2x Feld 1 ON Feld 2 1934 Feld 3 123 467 Feld 4 00BD 6 Bestätigen Sie die Eingabe Der Cursor wechselt in die Menü Ebene Enter H eine hexadezimale Ziffer ändern 1 Wechseln Sie in die Parameter Ebene siehe D 2 Wählen Sie die gewünschte Ziffer oder Feld 1 ON...

Страница 39: ...C3F Feld 5 ROJEKT1 P Feld 1 ON Feld 2 1934 Feld 3 123 467 Feld 4 1C3F Feld 5 RROJEKT1 Feld 1 ON Feld 2 1934 Feld 3 123 467 Feld 4 1C3F Feld 5 REZEPT2 2 Wählen Sie das gewünschte Zeichen oder 3 Ändern Sie das Zeichen z B R 4 Wiederholen Sie Schritt 3 bis der neue Wert eingegeben ist z B RE ZEPT P Q R 5 3x 5 Geben Sie eine Ziffer ein z B 2 G H I 2 4x 6 Bestätigen Sie die Eingabe Der Cursor wechselt ...

Страница 40: ...ablen die die Meldung aktiviert hat ƒ Die letzte Zeile zeigt Datum und Uhrzeit wann die Meldung ausgelöst wurde ƒ Die LED in der Taste Info blinkt wenn eine Informationsmeldung vorhanden ist Symbole und Zeichen in den Informationsmeldungen Symbole Zeichen in der Zeile Datum Uhrzeit Bedeutung Die Informationsmeldung wurde zum ersten Mal aufgerufen HELP Der Informationsmeldung ist eine Hilfe zugeord...

Страница 41: ...programmierbares Meldungsfeld Dieses Feld zeigt die numerische Größe der Variablen die die Meldung aktiviert hat ƒ Die letzte Zeile zeigt Datum und Uhrzeit wann die Meldung ausgelöst wurde ƒ Die LED in der Taste Alarm blinkt wenn eine Alarmmeldung vorhanden ist Symbole und Zeichen in den Alarmmeldungen Symbole 1 Zeichen in der Zeile Datum Uhrzeit Bedeutung Nicht quittierter Alarm Quittierter Alarm...

Страница 42: ...ter an Im Alarmregister ist das Auftreten des Alarms chronologisch nach Datum und Uhrzeit gespeichert Ein H in der linken Spalte signa lisiert dass ein Alarmregister an gewählt ist Enter Druck uebersteigt die Sicherheitsgrenze 125 5 13 09 2000 10 45a 13 09 2000 10 48a PdDn 13 09 2000 10 55a H 0001 3 Nächste oder vorherige Alarmmel dung im Alarmregister anwählen shift PgDN oder PgUp Wasserstand unt...

Страница 43: ...eldungen zugeordnet sein enthalten nützliche Hinweise die die Bedienung erleichtern müssen im Projektierungstool HMI Designer programmiert worden sein ƒ Die LED in der Taste Help blinkt wenn eine Hilfemeldung vorhanden ist Sie möchten Drücken Sie die Tasten Beispiel A eine Hilfemeldung aufrufen Help B die Hilfemeldung schließen Clr Esc ...

Страница 44: ...Sie möchten Drücken Sie die Tasten Beispiel A auf die Memory Card zugreifen l Tansfer Page wird angezeigt shift Enter H410 TRANSFER PAGE Graphic controller BOOT check OK F1 MSP F2 FlashCARD ENTER EXIT Graphic controller RAM check OK l Menü Flash Card anwählen F2 B Funktion anwählen FlashCARD MENU Back Up for H410 Firmware present Project present F1 BACKUP F2 RESTORE F3 ERASE F4 EXIT l BACKUP Proje...

Страница 45: ...aft l Anschlüsse auf festen Sitz prü fen l Leitung auf Beschädigung kon trollieren COM BROK Kommunika tion unter brochen Serielles Datenkabel zwi schen Bedieneinheit und PC ist defekt oder nicht richtig angeschlossen l Sub D Stecker auf richtigen An schluss und festen Sitz prüfen l Serielles Datenkabel austau schen RESET ERROR Kommunika tion mit Systembus CAN unter brochen l Fehlerhafte Verdrahtun...

Страница 46: ...p 9 1 49 8 1 Interne Batterie wechseln ƒ Eine geräteinterne Batterie sorgt dafür dass Rezeptdaten und Systemzeit Datum der Bedieneinheit bei abgeschalteter Spannungsversorgung erhalten bleiben ƒ Wenn die LED Battery an der Bedieneinheit leuchtet müssen Sie die Batterie auswechseln ƒ Daten der Batterie Lithium Batterie 3 V Æ19 mm Typ CR2032 ƒ Die Batterie gehört nicht zum Lieferumfang Stop ƒ Vor de...

Страница 47: ... 4 1 2 3 4 5 N C CAN Shield CAN V MSP fuse 800 mA back up card h410_008 Abb 8 1 Gehäusedeckel abnehmen 1 Schrauben lösen und Gehäusedeckel abnehmen Batterie wechseln 2 1 MSP h410_009 Abb 8 2 Batterie wechseln 1 Bügel anheben und Batterie entnehmen 2 Bügel anheben und neue Batterie einlegen Bügel ist Plus Anschluss ...

Страница 48: ...EDBPM H410 DE EN FR 4 1 Gehäusedeckel schließen 0 0 0 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V MSP fuse 800 mA back up card h410_008 Abb 8 3 Gehäusedeckel schließen 1 Gehäusedeckel aufsetzen Schrauben eindrehen und festziehen ...

Страница 49: ...PM H5xx und EPM H6xx bietet Lenze Schutzfolien an mit einer verbesserten Beständigkeit gegen die genannten Chemikalien Substanz Bedieneinheit EPM H3xx EPM H4xx EPM H5xx EPM H6xx mit Schutz folie Aceton L L J Ameisensäure 50 L L Ammoniak 2 L L Äthylenglykol L L L Ätznatron 2 L L Beizlösung konzentriert L Benzin J L L J Benzol J J L J Benzylalkohol L L Chlorwasserstoffsäure 10 L L Dieselöl J J J J E...

Страница 50: ...50 L L L L Toluol J J L J Trichlorethylen L J Unterchlorigsaures Na tron 20 L L Wasserstoffsuperoxyd 25 L L EPM H3xx EPM H310 EPM H312 EPM H315 EPM H4xx EPM H410 EPM H5xx EPM H502 EPM H505 EPM H507 EPM H510 EPM H515 EPM H520 EPM H521 EPM H525 EPM H6xx EPM H605 EPM H606 J Oberfläche ist beständig keine sichtbare Beschädigung L Oberfläche ist nicht beständig wird beschädigt nicht getestet ...

Страница 51: ...g 34 Begriffsdefinitionen 9 Betriebsanzeigen 32 C Chemikalienbeständigkeit 49 D Daten eingeben 36 sichern auf Memory Card 44 Datum einstellen 33 DC Spannungsversorgung 12 Definition der verwendeten Hinweise 10 Display 12 Kontrast einstellen 33 E Eigenschaften 13 Einbauausschnitt 18 Einsatzbedingungen 11 Feuchtebeanspruchung 11 Montagebedingungen Gewicht 11 Umgebungsbedingungen klimatisch 11 Einsch...

Страница 52: ...ekt Download 30 S Sicherheitshinweise Definition 10 Gestaltung 10 Speicher 12 Speicherbaustein Memory Card 44 Speichererweiterung ein ausbauen 25 Statusmeldungen 32 Störungsbeseitigung 45 Störungsmeldungen 45 Systembus CAN Baudrate 12 Kommunikationsmedium 12 Verdrahtung 23 T Tastenfunktionen 34 Technische Daten 11 Allgemeine Daten 11 DC Spannungsversorgung 12 Display 12 Einbauausschnitt 18 Einsatz...

Страница 53: ...Anhang Stichwortverzeichnis 9 53 EDBPM H410 DE EN FR 4 1 ...

Страница 54: ... 54 EDBPM H410 DE EN FR 4 1 Key for the overview Pos Description Function Terminal block 4 pole 24V DC voltage supply Terminal block 5 pole System bus CAN DB25 socket Serial port MSP for PC or PLC ...

Страница 55: ... 55 EDBPM H410 DE EN FR 4 1 This documentation applies to the EPM H410 operating unit from nameplate data Type EPM H410 1B 10 Product range EPM operating unit Hardware version Software version ...

Страница 56: ...4 0 06 2009 TD23 Change of company name 00457282 3 0 08 2002 TD23 Change of company name 00418423 2 0 08 2001 TD23 Complete revision for series production 00414159 1 0 03 2000 TD23 First edition for field test 0Fig 0Tab 0 Tip Information and auxiliary devices related to the Lenze products can be found in the download area at http www Lenze com ...

Страница 57: ... Mechanical installation 69 3 1 Labelling of operating unit 69 3 2 Mounting of the operating unit 71 4 Electrical installation 72 4 1 Supply voltage connection 72 4 2 Wiring of system bus CAN 73 4 3 Mountingand removing the memory card 75 4 3 1 4 MB memory card 75 5 Commissioning 78 5 1 Initial switch on 78 5 2 Project transfer to the operating unit 79 5 2 1 Connecting operating unit and PC 79 5 2...

Страница 58: ...alling up information messages 90 6 4 Calling up alarm messages 91 6 5 Calling up help messages 93 6 6 Saving data on the memory card 94 7 Troubleshootingand fault elimination 95 7 1 Fault messages 95 8 Maintenance 96 8 1 Battery replacement 96 9 Appendix 99 9 1 Chemical resistance 99 9 2 Index 101 ...

Страница 59: ...nd notes relevant for them ƒ These Operating Instructions must always be complete and perfectly readable 1 2 Terminology used Term Used in this text for Controller Lenze 8200 vector and 9300 vector frequency inverter Lenze 9300 and 9400 servo inverter HMI Human Machine Interface 1 3 Scope of supply Scope of supply Important l 1 EPM H410 operating unit without battery l 1 Operating Instructions l 6...

Страница 60: ...rough dangerous electrical voltage Reference to an imminent danger that may result in death or serious personal injury if the corresponding measures are not taken Danger Danger of personal injury through a general source of danger Reference to an imminent danger that may result in death or serious personal injury if the corresponding measures are not taken Stop Danger of property damage Reference ...

Страница 61: ...otection of persons and equipment Enclosure IP65 front EMC Applied standards for limit values EN 61000 6 4 2007 Noise emission Restriction of use Protection requirements are not ensured in residential areas EN 61000 6 2 2005 Noise immunity Restriction of use Protection requirements are not ensured in residential areas Operating conditions Ambient conditions Climate Storage 20 60 C Transport 20 60 ...

Страница 62: ...ckground illumination LED Electrical connection DC voltage supply DC 24 V 18 32 V Power consumption 11 W at DC 24 V Fusing Miniature fuse Æ5 20 mm 800 mA F Network System bus CAN Protocol CANopen CAL based communication profile DS301 Communication medium DIN ISO 11898 Network topology Line terminated at both ends with 120 W System bus node Master or slave Max number of stations 63 Baud rate kbps 2...

Страница 63: ... automatically memory trends detection Automatic operations Number 16 Backup restore Function Available Bar graph Function Available Commands Print alarm register Function Available Display alarm register Operating page Sheet feed on printer Set general page number to zero Hardcopy Help for the page Change password Password login Password logout Run pipeline End project Display project information...

Страница 64: ...ages total fields per page Number 1024 128 Dynamic bitmaps with bit group structure single bit structure or value structure Number 1024 1 Dynamic texts with bit group structure single bit structure or value structure Number 1024 1 E keys Function Available LEDs assigned to a sequence Function Available Labels Function Available F keys Function Available Clock field with seconds Function Available ...

Страница 65: ...on of E keys Function Available Local configuration of F keys Function Available Macro field Number per page 16 Macros total commands macro Number 1024 16 Message helps Number 1024 Message field Function Available Multilingual texts Number of languages 8 Password levels Number 10 Programmable fonts Function Available Project images Function Available Rectangles Function Available Reports Number 12...

Страница 66: ...alue and linear correction variables Number per page 80 Movement variables movable symbolic field Threshold variables Numerical floating point variables Numeric variables DEC HEX BIN BCD String variables ASCII Weekday field Function Available Public variables for ESANET network Number total bytes 128 1024 1 Guide value limited by the project size 2 Limited by the memory size ...

Страница 67: ...2 Interface description 1 14 h410_013 Fig 2 1 MSP DB25 socket Pin Signal 1 n c 2 Tx RS232 OUT 3 Rx RS232 IN 4 RTS RS232 OUT 5 CTS RS232 IN 6 n c 7 GND signal 8 n c 9 16 Signals are not evaluated 17 n c 18 Signal is not evaluated 19 21 n c 22 25 Signals are not evaluated n c not connected ...

Страница 68: ... Spare Clr Esc P Q R 5 S T U 6 Y Z 8 9 F2 F13 F24 F3 F14 F4 F15 F5 F16 F6 F17 F7 F18 F8 F19 F9 F20 F10 F21 F11 F22 Bus Error Ack All Ack PgUp PgDN h410_001 Fig 2 2 Dimensions a mm b mm d mm e mm 252 0 196 0 5 0 60 0 2 4 Mounting cutout a g g h b Æ k d e e f c h410_002 Fig 2 3 Mounting cutout a mm b mm c mm d mm e mm f mm g mm h mm k mm 232 0 178 0 242 0 186 0 29 0 120 0 116 0 5 0 4 5 ...

Страница 69: ... supply Different labels can be attached to the keypad ƒ The labels are only accessible when the keypad is not built in ƒ Ensure to have the labels ready for use before inserting the keypad into the mounting cut out 0 0 0 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V MSP fuse 800 mA back up card h410_008 Fig 3 1 Take off the housing cover 1 Loosen bolts and remove housing cover ...

Страница 70: ...eys F1 F5 Keys F6 F11 Keys F12 F16 Keys F17 F22 For labelling proceed as follows 2 Remove plate or from the slot and label it 3 After the new label has been written push it back into the slot 0 0 0 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V MSP fuse 800 mA back up card h410_008 Fig 3 3 Close housing cover 4 Replace the housing cover and tighten screws ...

Страница 71: ... 3 2 Mounting of the operating unit The dimensions for the mounting cut out can be found in the Technical data 68 0 h410_003 1 Push operating unit into the mounting cutout 2 1 3 h410_012 2 Fit plain washers 6 items 3 Screw nuts 6 items onto the threaded bolts 6 items and tighten them ...

Страница 72: ...t only when no voltage is applied 4 1 Supply voltage connection 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V INPUT VOLTAGE 18 32 VDC 11 W MSP PE N L1 fuse 800 mA back up card 18 32VDC h410_004 Fig 4 1 Supply voltage connection Terminal assignment Terminal Identification Explanation 1 24 VDC Supply voltage DC 18 V 32 V 2 0 VDC GND supply voltage reference potential 3 n c Not connected 4 ...

Страница 73: ... CAN V CAN N C CG LO HI CG LO CG LO HI CG LO HI HI 120 120 An A2 H410 A1 h410_006 Fig 4 2 Wiring of system bus CAN A1 Node 1 A2 Node 2 An Node n Connection 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V INPUT VOLTAGE 18 32 VDC 11 W MSP CAN GND CAN LO CAN HI fuse 800 mA back up card h410_019 Fig 4 3 System bus CAN connection ...

Страница 74: ...stem bus LOW data line 3 Shield Connect the shield of the system bus cable 4 CAN HI System bus HIGH data line 5 n c Not connected We recommend the use of CAN cables in accordance with ISO 11898 2 CAN cable in accordance with ISO 11898 2 Cable type Paired with shielding Impedance 120 W 95 140 W Cable resistance cross section Cable length 300 m 70 mW m 0 25 0 34 mm2 AWG22 Cable length 301 1000 m 40 ...

Страница 75: ...ily be damaged if not handled properly 4 3 1 4 MB memory card ƒ You can save and archive your custom designed configured project on this memory chip ƒ You can mount the memory chip with the saved project into an operating unit of the same type in order to transfer the project to this operating unit ƒ The 4 MB memory card can be ordered from Lenze under order no EPZ H210 Take off the housing cover ...

Страница 76: ... card 2 1 l Memory Card 4 MB h410_011 Fig 4 5 Mounting the memory card 1 Hold the memory chip so that the label is visible 2 Push the lug of the memory chip under the edge of the base 3 4 l Memory Card 4 MB h410_014 Fig 4 6 Latching the memory card 3 Carefully press memory chip in pos until it locks into place beneath the clip ...

Страница 77: ...mory Card 4 MB h410_015 Fig 4 7 Removing the memory card 1 Push back the clip until the memory chip is ejected 2 Carefully remove the memory chip Close housing cover 0 0 0 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V MSP fuse 800 mA back up card h410_008 Fig 4 8 Close housing cover 1 Replace the housing cover and tighten screws ...

Страница 78: ...missioning 5 1 Initial switch on Commissioning requires a complete wiring of the system bus Before switching on the supply voltage check ƒ the complete wiring for completeness and short circuit ƒ whether the bus system is terminated at the first and last physical node ...

Страница 79: ...rating unit and PC Stop Only connect PC and operating unit when the units are switched off l HMI Designer 0 1 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V INPUT VOLTAGE 18 32 VDC 11 W MSP fuse 800 mA back up card h410_005 Fig 5 1 Connecting operating unit and PC ƒ Connect EPZ H110 download cable to the MSP interface on the operating unit and to COM1 or COMx on the PC ...

Страница 80: ...ou can select whether you want to update the firmware at the time the project is loaded The firmware must always be updated with the first download of a project to the operating unit or after an update of the HMI Designer planning tool Tip Sample projects for the operating unit can be found in the HMI Designer planning tool under File Open Samples ...

Страница 81: ...ng unit On the display the following selection is shown F1 MSP F2 Memory CARD only if the card is mounted ENTER EXIT 4 Press F1 key to activate download via the MSP interface 5 If the message Waiting for download from MSP appears on the display load the desired project from the HMI Designer into the operating unit See HMI Designer Getting started Manual PROGRAMMING MODE is displayed during the dow...

Страница 82: ...t error You want to Press keys Example A query the status of the operating unit shift 2x Port MSP Driver CAN Lenze M Ver 1 01 Addr VT NO ADDR Error NO ERROR ENTER Set Clock Contrast B close the status display Clr Esc 5 4 Status displays on the operating unit Display On Off Blinking LED red Bus error No communication error Communication error on the system bus CAN LED green Power Supply voltage swi...

Страница 83: ...rast Enter B Set the date time 1 Select SET CLOCK menu PgUp or PgDN SET CONTRAST 04 SET CLOCK Wed 13 09 00 12 50 10 2 Select menu Enter 3 Select desired field or 12 50 10 13 09 00 4 Change value PgUp or PgDN 5 If necessary repeat steps 3 and 4 to change further values 6 Confirm entry Enter C Set the contrast of the display 1 Select SET CONTRAST menu PgUp or PgDN SET CONTRAST 04 SET CLOCK Wed 13 09...

Страница 84: ...eter entry quit help information and status messages shift Clr Esc Clr Parameter level Restores the original value while the data are entered PgUp PgUp Up arrow Menu level Select previous page Parameter level Select previous dynamic text PgDN PgDn Down arrow Menu level Select next page Parameter level Select next dynamic text Left arrow Menu level Place cursor on previous field Parameter level Pla...

Страница 85: ...blinking if information message is available Alarm Show alarm message LED is blinking if alarm message is available Alarm Reset acknowledge displayed alarm shift Alarm Reset acknowledge all alarms available Programmable key e g to start a printing process HMI Designer manual Spare No function Note The function keys Fx can be programmed using the HMI Designer software ƒ Lenze setting Without functi...

Страница 86: ...e A select a menu F1 F24 B select a page PgUp or PgDN C place the cursor on the previous or next field or Feld 1 ON Feld 2 987 Feld 3 123 467 Feld 4 1A3F 6 D change to the parameter level l The cursor is placed on the right digit l In an alphanumeric or dynamic field the cursor is placed on the left character see J or I Feld 1 ON Feld 2 987 Feld 3 123 467 Feld 4 1A3F 6 ...

Страница 87: ...2 001 Feld 3 123 467 Feld 4 1A3F 2 5 If necessary enter a floating point shift Space Feld 1 ON Feld 2 012 Feld 3 123 467 Feld 4 1A3F TIP Floating points can only be inserted if the field is defined as Floating Point see HMI Designer planning tool 6 Repeat step 4 until the value is complete 7 If necessary enter a sign Space Feld 1 ON Feld 2 12 3 Feld 3 123 467 Feld 4 1A3F 4 8 Confirm the input The ...

Страница 88: ... e g D The digits entered will shift one place to the left 5 Repeat step 4 until the value is complete D E F 1 2x Feld 1 ON Feld 2 1934 Feld 3 123 467 Feld 4 00BD 6 Confirm the input The cursor changes to the menu level Enter H change a hexadecimal digit 1 Change to the parameter level see D 2 Select the desired digit or Feld 1 ON Feld 2 1934 Feld 3 123 467 Feld 4 1 3F C 3 Change the digit e g C A...

Страница 89: ... Feld 4 1C3F Feld 5 ROJEKT1 P Feld 1 ON Feld 2 1934 Feld 3 123 467 Feld 4 1C3F Feld 5 RROJEKT1 Feld 1 ON Feld 2 1934 Feld 3 123 467 Feld 4 1C3F Feld 5 REZEPT2 2 Select the desired character or 3 Change the character e g R 4 Repeat step 3 until the new value is entered e g RECIPE P Q R 5 3x 5 Enter a digit e g 2 G H I 2 4x 6 Confirm the input The cursor changes to the menu level Enter ...

Страница 90: ...the variable that has activated the message ƒ The last line shows the date and time when the message was triggered ƒ The LED in the Info key will flash if an information message is available Symbols and characters in the information messages Symbols characters used in the line for date time Meaning The information message has been called up for the first time HELP Help is assigned to the informati...

Страница 91: ...ontains a programmable message field This field indicates the numerical value of the variable that has activated the message ƒ The last line shows the date and time when the message was triggered ƒ The LED in the Alarm key will flash if an alarm message is available Symbols and characters used in alarm messages Symbols 1 Characters used in the date time line Meaning Alarm not acknowledged Acknowle...

Страница 92: ... the alarm register The alarm register logs all alarms chronologically with time and date stamping If H is displayed in the left column an alarm register has been selected Enter Druck uebersteigt die Sicherheitsgrenze 125 5 13 09 2000 10 45a 13 09 2000 10 48a PdDn 13 09 2000 10 55a H 0001 3 Select the next or previous alarm message in the alarm register shift PgDN or PgUp Wasserstand unterhalb der...

Страница 93: ... be assigned to pages or information messages contain useful notes to make handling easier must have been programmed in the HMI Designer planning tool ƒ The LED in the Help key will flash if a help message is available If you want to Press keys Example A call up a help message Help B close a help message Clr Esc ...

Страница 94: ... to Press keys Example A access the memory card l Tansfer page is shown shift Enter H410 TRANSFER PAGE Graphic controller BOOT check OK F1 MSP F2 FlashCARD ENTER EXIT Graphic controller RAM check OK l Select the Flash Card menu F2 B Select the function FlashCARD MENU Back Up for H410 Firmware present Project present F1 BACKUP F2 RESTORE F3 ERASE F4 EXIT l BACKUP Save project from the operating uni...

Страница 95: ...C is faulty l Check connections for tight fit l Check cable for damage COM BROK Communication interrupted Serial data cable between operating unit and PC is defective or not correctly connected l Check correct connection and tight fit of Sub D plug l Exchange serial data cable RESET ERROR Communication with system bus CAN interrupted l Faulty wiring e g polarity of the system bus l Faulty paramete...

Страница 96: ...ble in chapter 9 1 99 8 1 Battery replacement ƒ A device internal battery renders it possible to keep recipe data and the system time date of the operating unit stored if the voltage supply is switched off ƒ If the Battery LED on the operating unit is lit you have to replace the battery ƒ Data of the battery Lithium battery 3 V Æ19 mm type CR2032 ƒ The battery is not included in the scope of suppl...

Страница 97: ...3 4 1 2 3 4 5 N C CAN Shield CAN V MSP fuse 800 mA back up card h410_008 Fig 8 1 Take off the housing cover 1 Loosen bolts and remove housing cover Battery replacement 2 1 MSP h410_009 Fig 8 2 Battery replacement 1 Lift bracket and remove battery 2 Lift bracket and insert new battery bracket is the positive terminal ...

Страница 98: ...ment 8 98 EDBPM H410 DE EN FR 4 1 Close housing cover 0 0 0 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V MSP fuse 800 mA back up card h410_008 Fig 8 3 Close housing cover 1 Replace the housing cover and tighten screws ...

Страница 99: ...rating units Lenze offers protective foils with an improved resistance against the listed chemicals Substance Operating unit EPM H3xx EPM H4xx EPM H5xx EPM H6xx With protective foil Acetic acid 5 50 L L L J Acetone L L J Ammonia 2 L L Benzene J L L J Benzole J J L J Benzyl alcohol L L Diesel oil J J J J Ethanol L L L J Ethylene glycol L L L Formic acid 50 L L High pressure and temperature 100 C L ...

Страница 100: ...Concentrated L Pure acetic acid L L Sodium hydroxide 2 L L Sodium hydroxide 50 L L L Sulphuric acid 50 L L L L Toluol J J L J Trichloroethylene L J EPM H3xx EPM H310 EPM H312 EPM H315 EPM H4xx EPM H410 EPM H5xx EPM H502 EPM H505 EPM H507 EPM H510 EPM H515 EPM H520 EPM H521 EPM H525 EPM H6xx EPM H605 EPM H606 J Surface resists no visible damage L Surface does not resist visible damage Not tested ...

Страница 101: ...tes used 60 Definitions 59 Display 62 Contrast setting 83 E Electrical data 62 Electrical installation 72 Connecting the supply voltage 72 F Fault messages 95 G General data 61 H Help messages 93 Human Machine Interface 59 Humidity 61 I Information messages 90 Initial switch on 78 Installation system bus CAN 73 Installation electrical 72 Installation electrical connecting the supply voltage 72 Ins...

Страница 102: ... P Parameters 63 PC Connecting with the operating unit 79 Disconnecting from the operating unit 81 Power consumption 62 Project Download 80 Project transfer to the operating unit 79 S Safety instructions definition 60 layout 60 Status displays 82 Status messages 82 Switch on initial 78 System bus CAN baud rate 62 communication medium 62 wiring 73 T Technical data 61 DC voltage supply 62 display 62...

Страница 103: ...Appendix Index 9 103 EDBPM H410 DE EN FR 4 1 ...

Страница 104: ... 104 EDBPM H410 DE EN FR 4 1 Légende Pos Description Fonction Bornier 4 bornes Alimentation 24 V CC Bornier 5 bornes Bus Système CAN Prise DB25 Port série MSP pour ordinateur ou API ...

Страница 105: ... H410 DE EN FR 4 1 Validité Unité de commande EPM H410 à partir de la version ci dessous voir plaque signalétique Type EPM H410 1B 10 Série d appareils EPM Unité de commande Version matérielle Version logicielle ...

Страница 106: ...D23 Changement de raison sociale 00457282 3 0 08 2002 TD23 Changement de raison sociale 00418423 2 0 08 2001 TD23 Texte entièrement revu pour la série 00414159 1 0 03 2000 TD23 Première édition pour essais sur le terrain 0Fig 0Tab 0 Conseil Toutes les informations relatives aux produits Lenze peuvent être téléchargées sur notre site à l adresse suivante http www Lenze com ...

Страница 107: ...9 3 1 Marquage de l unité de commande 119 3 2 Montage de l unité de commande 121 4 Installationélectrique 122 4 1 Raccordement de la tension d alimentation 122 4 2 Câblage du bus système CAN 123 4 3 Insertion retraitde la carte mémoire 125 4 3 1 Carte mémoire 4 Mo Memory Card 125 5 Mise en service 128 5 1 Première mise en service 128 5 2 Téléchargementd un projet sur l unité de commande 129 5 2 1 ...

Страница 108: ...n 140 6 4 Afficher un message d alarme 141 6 5 Recherched une rubrique d aide 143 6 6 Sauvegarde des données sur la carte mémoire 144 7 Détection et élimination des anomalies de fonctionnement 145 7 1 Messages d erreur 145 8 Maintenance 146 8 1 Remplacement de la batterie interne 146 9 Annexe 149 9 1 Résistance aux produits chimiques 149 9 2 Index 151 ...

Страница 109: ...ntes ƒ Les instructions de mise en service doivent être complètes et lisibles en toute circonstance 1 2 Terminologie Terme Utilisé dans le présent document pour désigner Variateur de vitesse les convertisseurs de fréquence 8200 vector et 9300 vector et les servovariateurs 9300 et 9400 de Lenze HMI une interface homme machine Human Machine Interface 1 3 Equipementlivré Equipement livré Important l ...

Страница 110: ...ur conséquences des blessures mortelles ou très graves en cas de non respect des consignes de sécurité correspondantes Danger Situation dangereuse pour les personnes en raison d un danger d ordre général Indication d un danger imminent qui peut avoir pour conséquences des blessures mortelles ou très graves en cas de non respect des consignes de sécurité correspondantes Stop Risques de dégâts matér...

Страница 111: ...il Indice de protection IP65 à l avant CEM Normes appliquées pour les valeurs limites EN 61000 6 4 2007 Perturbations radioélectriques Restriction d utilisation en environnement résidentiel le respect des exigences de protection n est pas garanti EN 61000 6 2 2005 Protection contre les parasites Restriction d utilisation en environnement résidentiel le respect des exigences de protection n est pas...

Страница 112: ... électrique Alimentation CC 24 V CC 18 32 V Puissance absorbée 11 W pour 24 V CC Protection par fusible Fusible pour faible intensité Æ5 20 mm 800 mA F Réseau Bus Système CAN Protocole CANopen profil de communication DS301 basé sur CAL Support de communication DIN ISO 11898 Topologie du réseau Ligne fermée des deux extrémités avec 120 W Participant au Bus Système Maître ou esclave Nombre maxi de p...

Страница 113: ...es identifiées automatiquement mémoire tendances saisies Opérations automatiques nombre 16 Sauvegarde reconstitution fonction oui Graphe à barres fonction oui Instructions Imprimer registre d alarmes fonction oui Afficher registre d alarmes Page de commande Alimentation papier imprimante Mise à zéro du numéro de page général Copie d écran Aide sur la page Modifier le mot de passe Mot de passe de c...

Страница 114: ... de données fonction oui Variables système affectées au format de recette fonction oui Instruction directe avec format SOUSTRAIRE fonction oui ENTRER OU ET XOR AJOUTER Imprimer fonction oui Pages à imprimer total champs par page nombre 1024 128 Bitmaps dynamiques avec différents formats cordon de bits bit individuel ou valeur nombre 1024 1 Textes dynamiques avec les différents formats cordon de bi...

Страница 115: ...nction oui Messages d information total activés simultanément 1024 256 Registre interne nombre 4096 octets En tête pied de page total champs par en tête pied de page 128 128 Cercles fonction oui Lignes fonction oui Configuration locale des touches E fonction oui Configuration locale des touches F fonction oui Champ macro nombre par page 16 Macros total instructions macro nombre 1024 16 Rubriques d...

Страница 116: ...émoire tampon pour tendances nombre 128 Tendances tendances pages canaux tendances nombre 2 2 Variables Variables limites et linéaires de correction nombre par page 80 Variables de mouvement champ symbolique mobile Variables seuil Variables numériques à virgule flottante Variables numériques DEC HEX BIN BCD Variables au format ASCII Champ Jour de la semaine fonction oui Variables publiques pour ré...

Страница 117: ...2 2 2 Affectation de la prise 1 14 h410_013 Fig 2 1 Prise MSP DB25 Broche Signal 1 N C 2 Tx RS232 OUT 3 Rx RS232 IN 4 RTS RS232 OUT 5 CTS RS232 IN 6 N C 7 Signal GND 8 N C 9 16 Les signaux ne sont pas traités 17 N C 18 Le signal n est pas traité 19 21 N C 22 25 Les signaux ne sont pas traités N C Non connecté ...

Страница 118: ...nter Spare Clr Esc P Q R 5 S T U 6 Y Z 8 9 F2 F13 F24 F3 F14 F4 F15 F5 F16 F6 F17 F7 F18 F8 F19 F9 F20 F10 F21 F11 F22 Bus Error Ack All Ack PgUp PgDN h410_001 Fig 2 2 Encombrements a mm b mm d mm e mm 252 0 196 0 5 0 60 0 2 4 Encoche de montage a g g h b Æ k d e e f c h410_002 Fig 2 3 Encoche de montage a mm b mm c mm d mm e mm f mm g mm h mm k mm 232 0 178 0 242 0 186 0 29 0 120 0 116 0 5 0 4 5 ...

Страница 119: ...L unité de commande permet le changement d étiquettes ƒ Les étiquettes ne sont accessibles que si l unité de commande est démontée ƒ Remplir les étiquettes avant de monter l unité de commande dans l encoche de montage 0 0 0 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V MSP fuse 800 mA back up card h410_008 Fig 3 1 Retirer le couvercle du boîtier 1 Desserrer les vis et retirer le couvercl...

Страница 120: ... F16 Touches F17 F22 Pour apposer les informations voulues sur les étiquettes 2 Retirer l étiquette ou et y inscrire les informations voulues 3 Remettre ensuite l étiquette en place en la faisant glisser dans la fente 0 0 0 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V MSP fuse 800 mA back up card h410_008 Fig 3 3 Fermer le couvercle du boîtier 4 Mettre en place le couvercle du boîtier i...

Страница 121: ...e de l unité de commande Pour les cotes de l encoche de montage se reporter au chapitre Spécifications techniques 118 0 h410_003 1 Insérer l unité de commande dans l encoche de montage 2 1 3 h410_012 2 Mettre en place les rondelles en U 6 3 Visser et serrer les écrous 6 sur les boulons filetés 6 ...

Страница 122: ...l unité de commande qu en l absence de tension 4 1 Raccordement de la tension d alimentation 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V INPUT VOLTAGE 18 32 VDC 11 W MSP PE N L1 fuse 800 mA back up card 18 32VDC h410_004 Fig 4 1 Raccordement de la tension d alimentation Affectation des bornes Borne Désignation Explication 1 24 V CC Tension d alimentation 18 V 32 V CC 2 0 V CC GND tensi...

Страница 123: ...I CG LO CG LO HI CG LO HI HI 120 120 An A2 H410 A1 h410_006 Fig 4 2 Câblage du Bus Système CAN A1 Participant au bus 1 A2 Participant au bus 2 An Participant au bus n Raccordement 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V INPUT VOLTAGE 18 32 VDC 11 W MSP CAN GND CAN LO CAN HI fuse 800 mA back up card h410_019 Fig 4 3 Raccordement Bus Système CAN ...

Страница 124: ...O Bus Système LOW ligne de données 3 Shield Blindage du câble bus 4 CAN HI Bus Système HIGH ligne de données 5 N C Non raccordé Il est recommandé d utiliser des câbles CAN conformes à la norme ISO 11898 2 Câbles CAN conformes à la norme ISO 11898 2 Type de câble Paire blindée Impédance 120 W 95 140 W Résistance et section de câble Longueur de câble 300 m 70 mW m 0 25 0 34 mm2 AWG22 Longueur de câb...

Страница 125: ...ables par un maniement inadéquat 4 3 1 Carte mémoire 4 Mo Memory Card ƒ Cette carte mémoire vous permet de sauvegarder et d archiver le projet configuré spécifique à votre application ƒ La carte mémoire contenant le projet sauvegardé peut être intégré dans une unité de commande du même type en vue du transfert du projet dans celle ci ƒ Référence de commande Lenze de la carte mémoire 4 Mo EPZ H210 ...

Страница 126: ... Memory Card 4 MB h410_011 Fig 4 5 Insertion de la carte mémoire Memory Card 1 Tenir la carte mémoire de manière à ce que l étiquette soit visible 2 Insérer la partie saillante de la carte mémoire sous l arête 3 4 l Memory Card 4 MB h410_014 Fig 4 6 Encliquetage de la carte mémoire 3 Appuyer avec précaution au niveau jusqu à ce que la carte mémoire soit encliquetée sous ...

Страница 127: ... 4 7 Démontage de la carte mémoire Memory Card 1 Appuyer sur l élément de serrage pour dégager la carte mémoire 2 Retirer la carte mémoire avec précaution Fermer le couvercle du boîtier 0 0 0 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V MSP fuse 800 mA back up card h410_008 Fig 4 8 Fermer le couvercle du boîtier 1 Mettre en place le couvercle du boîtier introduire les vis et les serrer ...

Страница 128: ... mise en service Pour la mise en service il est impératif que le Bus Système soit correctement raccordé Avant la mise sous tension vérifier ƒ le câblage dans son intégralité pour éviter un court circuit ƒ si des résistances d extrémité de bus sont raccordées au premier et au dernier participant au bus ...

Страница 129: ...entre l unité de commande et le PC Stop Ne relier le PC à l unité de commande qu en l absence de tension l HMI Designer 0 1 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V INPUT VOLTAGE 18 32 VDC 11 W MSP fuse 800 mA back up card h410_005 Fig 5 1 Etablissement de la liaison entre l unité de commande au PC ƒ Enficher le câble de téléchargement EPZ H110 sur l interface MSP de l unité de comm...

Страница 130: ...met de déterminer si le micrologiciel doit être actualisé simultanément au chargement du projet Il faut toujours procéder à l actualisation du micrologiciel lors du premier téléchargement d un projet sur l unité de commande et après une mise à jour de l outil de conception HMI Designer Conseil Pour les exemples de projet de l unité de commande voir l outil de conception HMI Designer Fichier Ouvrir...

Страница 131: ...écran les choix suivants sont proposés F1 MSP F2 Memory CARD uniquement si carte mémoire insérée ENTER EXIT 4 Appuyer sur la touche F1 pour effectuer un téléchargement via l interface MSP 5 A l apparition du message Waiting for download from MSP charger le projet HMI Designer voulu sur l unité de commande Voir aussi le manuel HMI Designer Premiers pas Pendant le téléchargement PROGRAMMING MODE s a...

Страница 132: ... date Error Pour Appuyer sur les touches Exemple A connaître l état de l unité de commande shift 2x Port MSP Driver CAN Lenze M Ver 1 01 Addr VT NO ADDR Error NO ERROR ENTER Set Clock Contrast B fermer l affichage d état Clr Esc 5 4 Affichagedes états de fonctionnement sur l unité de commande Voyant Allumé Eteint Clignotant LED rouge Bus Error Pas d erreur de communication Erreur de communication ...

Страница 133: ...la date l heure 1 Sélectionner le menu SET CLOCK PgUp ou PgDN SET CONTRAST 04 SET CLOCK Wed 13 09 00 12 50 10 2 Sélectionner un menu Enter 3 Sélectionner le champ souhaité ou 12 50 10 13 09 00 4 Modifier la valeur PgUp ou PgDN 5 Le cas échéant reprendre les points 3 et 4 pour modifier d autres valeurs 6 Valider la saisie Enter C régler le contraste de l écran 1 Sélectionner le menu SET CONTRAST Pg...

Страница 134: ...nformation et d état shift Clr Esc Clr Niveau paramètres remettre le paramètre à la valeur initiale PgUp PgUp Flèche vers le haut Niveau menu sélectionner la page précédente Niveau paramètres sélectionner le texte dynamique précédent PgDN PgDn Flèche vers le bas Niveau menu sélectionner la page suivante Niveau paramètres sélectionner le texte dynamique suivant Flèche vers la gauche Niveau menu pla...

Страница 135: ... disponible Alarm Alarme Afficher un message d alarme la LED clignote lorsqu un message d alarme est disponible Alarm Ack Désactiver acquitter l alarme shift Alarm All Ack Désactiver acquitter toutes les alarmes Imprimer Touche programmable permettant par exemple de lancer une procédure d impression manuel HMI Designer Spare Spare Pas de fonction Remarque importante Les touches de fonction Fx peuv...

Страница 136: ... sélectionner un menu F1 F24 B sélectionner une page PgUp ou PgDN C placer le curseur sur le champ suivant ou le champ précédent ou Feld 1 ON Feld 2 987 Feld 3 123 467 Feld 4 1A3F 6 D passer au niveau paramètres l Le curseur est placé sur le chiffre droit l Dans une zone de description alphanumérique ou dynamique le curseur est placé sur le caractère de gauche voir J ou I Feld 1 ON Feld 2 987 Feld...

Страница 137: ...1 ON Feld 2 001 Feld 3 123 467 Feld 4 1A3F 2 5 Le cas échéant mettre une virgule flottante shift Space Feld 1 ON Feld 2 012 Feld 3 123 467 Feld 4 1A3F Conseil Pour pouvoir insérer une virgule flottante le champ doit être défini comme floating point voir outil de conception HMI Designer 6 Répéter l étape 4 jusqu à ce que la valeur soit entrée en entier 7 Selon le cas insérer un signe Space Feld 1 O...

Страница 138: ...a position suivante exemple D Les chiffres entrés sont placés à gauche d une position 5 Répéter l étape 4 jusqu à ce que la valeur soit entrée en entier D E F 1 2x Feld 1 ON Feld 2 1934 Feld 3 123 467 Feld 4 00BD 6 Valider Le curseur passe au niveau menu Enter H modifier un chiffre hexadécimal 1 Passer au niveau paramètres voir D 2 Sélectionner le chiffre souhaité ou Feld 1 ON Feld 2 1934 Feld 3 1...

Страница 139: ... Feld 4 1C3F Feld 5 ROJEKT1 P Feld 1 ON Feld 2 1934 Feld 3 123 467 Feld 4 1C3F Feld 5 RROJEKT1 Feld 1 ON Feld 2 1934 Feld 3 123 467 Feld 4 1C3F Feld 5 REZEPT2 2 Sélectionner le caractère souhaité ou 3 Modifier le caratère exemple R 4 Répéter l étape 3 jusqu à ce que la nouvelle valeur soit entrée exemple RECETTE P Q R 5 3x 5 Entrer un chiffre exemple 2 G H I 2 4x 6 Valider Le curseur passe au nive...

Страница 140: ...le numérique des variables activées par le message ƒ La dernière ligne indique la date et l heure d activation du message ƒ La LED de la touche Info clignote lorsqu un message d information est disponible Symboles et caractères des messages d information Symbole caractères de la ligne Date heure Signification Ce message d information a été consulté pour la première fois HELP Une rubrique d aide es...

Страница 141: ...L avant dernière ligne contient un champ de message programmable Ce champ indique la taille numérique des variables activées par le message ƒ La dernière ligne indique la date et l heure d activation du message ƒ La LED de la touche Alarm clignote dès qu un message d alarme est émis Symboles et caractères des messages d alarme Symbole 1 Caractères à la ligne Date heure Signification Alarme non acq...

Страница 142: ...d alarmes contient les messages d alarme sauvegardés dans l ordre chronologique par date et heure Le H dans la colonne de gauche indique qu un registre d alarmes a été sélectionné Enter Druck uebersteigt die Sicherheitsgrenze 125 5 13 09 2000 10 45a 13 09 2000 10 48a PdDn 13 09 2000 10 55a H 0001 3 Sélectionner le message d alarme suivant ou précédent dans le registre shift PgDN ou PgUp Wasserstan...

Страница 143: ...s aux pages ou aux messages d information contiennent des conseils pratiques facilitant la commande doivent être programmés à l aide de l outil de conception HMI Designer ƒ La LED de la touche Help clignote lorsqu une rubrique d aide est disponible Pour appuyer sur les touches Exemple A afficher un message d aide Help B fermer le message d aide Clr Esc ...

Страница 144: ...puyer sur les touches Exemple A accéder à la carte mémoire l L écran Tansfer Page apparaît shift Enter H410 TRANSFER PAGE Graphic controller BOOT check OK F1 MSP F2 FlashCARD ENTER EXIT Graphic controller RAM check OK l Sélectionner le menu Flash Card F2 B sélectionner une fonction FlashCARD MENU Back Up for H410 Firmware present Project present F1 BACKUP F2 RESTORE F3 ERASE F4 EXIT l BACKUP Sauve...

Страница 145: ... Vérifier si les raccords sont bien serrés l Vérifier si le câble est endommagé COM BROK Communicat ion interrompue Le câble de données série reliant l unité de commande et le PC est défectueux ou n est pas correctement connecté l Vérifier si le connecteur SUB D mâle est correctement enfiché l Echanger le câble de données série RESET ERROR Communicat ion avec Bus Système CAN interrompue l Câblage ...

Страница 146: ...e interne ƒ Une batterie intégrée à l appareil garantit la sauvegarde des données relatives aux recettes de fabrication et du réglage de l horloge heure et date de l unité de commande en cas de coupure de l alimentation ƒ Si la LED Battery de l unité de commande s allume remplacer la batterie ƒ Caractéristiques de la batterie Batterie au lithium 3 V Æ19 mm type CR2032 ƒ La batterie n est pas compr...

Страница 147: ...N Shield CAN V MSP fuse 800 mA back up card h410_008 Fig 8 1 Retirer le couvercle du boîtier 1 Desserrer les vis et retirer le couvercle du boîtier Remplacement de la batterie 2 1 MSP h410_009 Fig 8 2 Remplacement de la batterie 1 Soulever l étrier et retirer la batterie 2 Soulever l étrier et mettre en place la nouvelle batterie étrier raccordement positif ...

Страница 148: ...H410 DE EN FR 4 1 Fermer le couvercle du boîtier 0 0 0 24 VDC 0 VDC N C 1 2 3 4 1 2 3 4 5 N C CAN Shield CAN V MSP fuse 800 mA back up card h410_008 Fig 8 3 Fermer le couvercle du boîtier 1 Mettre en place le couvercle du boîtier introduire les vis et les serrer ...

Страница 149: ...e commande EPM H5xx et EPM H6xx Lenze vous propose des protecteurs d écran avec une résistance améliorée aux produits chimiques mentionnés Substance Unité de commande EPM H3xx EPM H4xx EPM H5xx EPM H6xx Avec protecteur d écran Acétone L L J Acide acétique 5 50 L L L J Acide acétique glacial L L Acide chlorhydrique 10 L L Acide formique 50 L L Acide nitrique 5 10 L L L J Acide phosphorique 30 L L L...

Страница 150: ...d hydrogène 25 L L Tétrachloréthylène L J Toluène J J L J Trichloréthylène L J EPM H3xx EPM H310 EPM H312 EPM H315 EPM H4xx EPM H410 EPM H5xx EPM H502 EPM H505 EPM H507 EPM H510 EPM H515 EPM H520 EPM H521 EPM H525 EPM H6xx EPM H605 EPM H606 J L interface opérateur résiste à la substance chimique aucun endommagement visible L L interface opérateur ne résiste pas à la substance chimique interface op...

Страница 151: ...ions de montage Poids 111 Consignes de sécurité Définition 110 Présentation 110 Contraste réglage 133 D Date réglage 133 Définition des remarques utilisées 110 Détection des défauts Messages d erreur 145 Données saisie des données 136 Sauvegarde sur la carte mémoire 144 E Ecran 112 Electricité installation Raccordement de la tension d alimentation 122 Elimination des anomalies de fonctionnement 14...

Страница 152: ...pécifications techniques 111 Affectation de la prise 117 Alimentation CC 112 Bus Système CAN 112 Caractéristiques électriques 112 Caractéristiques générales 111 Conditions d utilisation 111 Ecran 112 Encoche de montage 118 Mémoire 112 Puissance absorbée 112 Raccordement électrique 112 T Terminologie 109 U Unité de commande Déconnexion du PC 131 Affectation de la prise 117 Affichage des états de fo...

Страница 153: ...Annexe Index 9 153 EDBPM H410 DE EN FR 4 1 ...

Страница 154: ...rmany Service Lenze Service GmbH Breslauer Straße 3 D 32699 Extertal Germany 49 0 51 54 82 0 00 80 00 24 4 68 77 24 h helpline Ê 49 0 51 54 82 28 00 Ê 49 0 51 54 82 11 12 Lenze Lenze de Service Lenze de ü www Lenze com EDBPM H410 DE EN FR 4 1 TD00 10 9 8 7 6 5 4 3 2 1 ...

Отзывы: