Commissioning
Carrying out basic settings with GDC
95
EDBCSXS064 EN 4.0
6.3
Carrying out basic settings with GDC
Note!
Follow the commissioning steps in the given order!
Settings
Brief description
Detailed
information
Preconditions
l
Mains is switched off. (Green LED is dark, red LED is
blinking)
l
Controller inhibit is active.
– Press the <F9> key in GDC.
– X6/SI1
or
X6/SI2 must be open (LOW).
1.
Switch on low−voltage supply
(24 V DC).
2.
Connect PC/laptop (with
installed GDC parameter
setting program) to controller.
Connection to terminal X14 (CAN−AUX) with PC system bus
adapter.
3.
Start GDC and select the device
to be set.
Select device:
Change to the online mode via the GDC toolbar with the
<F4> key and select "Searching for drives" using the <F2>
key.
ð
Drive is identified and the parameter menu is opened.
GDC online
help
4.
Load Lenze setting.
l
Not required for initial commissioning of the axis
module.
l
Only recommended if the Lenze setting is unclear.
5.
Set communication parameters
according the interface used.
Comm. parameters − AIF interface:
Please read the documentation for the Lenze
communication module used!
Comm. parameters − CAN interface:
l
CAN node address (via DIP switch or C0350/C2450)
l
Baud rate (via DIP switch or C0351/C2451)
l
C0356 (CAN boot up/cycle time)
l
C1120 = 1 (sync connection via MotionBus (CAN))
l
C1121 (synchronisation cycle [in ms])
6.
Set mains data.
Set the following codes in the GDC parameter menu under
Short setup
Mains
:
l
C0173 (voltage thresholds)
l
C0175 (function of the charge relay)
– For operation with the power supply module ECSxE
set C0175 = 3.
7.
Enter motor data.
Lenze motors:
Use the GDC motor assistant.
Motors from other manufacturers:
Set the codes in the GDC parameter menu under
Motor/feedback systems
Motor setting
.
8.
Configure holding brake.
l
Not required if a holding brake is not available;
otherwise
l
set C0472/10 (speed threshold) > 0 (e. g. 1 %) for closing
the holding brake.
9.
Set feedback system.
l
Set Lenze motors with resolvers (standard) in the GDC
parameter menu under
Short setup
Feedback system
.
l
Set other resolvers and encoders in the GDC parameter
menu under
Motor/feedback systems
Feedback
system
.