Technical data
2
32
EDK94ZPM113 DE/EN/FR/ES/IT 1.0
2
Technical data
The standards, operating conditions and rated data correspond to the ones of
the standard device for which the installation backplane is intended.
Assignment of installation backplane – standard device
Axis controller type
Installation backplane
type
Fuse
Device size
E94AMxE0024
E94AZPM0044
Siba 5020106.16A
I
E94AMxE0034
E94AMxE0044
E94AMxE0074
E94AZPM0094
Siba 5020106.40A
II
E94AMxE0094
E94AMxE0134
E94AZPM0244
Siba 2029221.100A
(tightening torque:
3.4 Nm (30 lb-in))
III
E94AMxE0174
E94AMxE0244
Note!
The devices must be installed in housings (e.g. control cabinets) to
meet applicable regulations.
Содержание E94AZPM Series