Lenze · E94AYCEO communication module (EtherNet/IP™) · Communication Manual · DMS 3.0 EN · 12/2013 · TD17
14
3
Product description
3.3
Product features
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.3
Product features
• Interface module for the EtherNet/IP communication system to be connected to the expansion
slots of the Servo Drives 9400
• The communication module can either be supplied internally by the standard device or
externally by a separate voltage source.
• The Servo Drive 9400 is always an adapter device:
EtherNet/IP adapter with "Level 2" functionality
• 2-port interface with integrated switch functionality
• Access to all Lenze parameters (configurable via TCP/IP using the Lenze »Engineer«)
• Up to 3 TCP/IP socket connections for communication with the Lenze »Engineer«
• Support of "IP Config Pending" (activation of changed IP configuration by "power off/on" or
"type 0 reset")
• Support of the redundancy protocol DLR (Device Level Ring) as "beacon-based ring node"
• Up to 32 I/O data words (64 bytes) are possible.
• Further CIP features:
• Max. 8 CIP connections
• 1 "exclusive owner" connection
• I/O connection type: cyclic
• Minimum I/O cycle time: 2 ms
• Support of multicast messages, "IGMP snooping" (V2 according to RFC 2236), UCMM, ACD,
BOOTP/DHCP, VLAN tagging/DSCP