Electrical installation
Control terminals
26
GHB 13.0001−EN EN 3.0
5.5
Control terminals
The digital and analog inputs and outputs are placed in the plug X5. The digital and analog
inputs and outputs have the same reference potential.
X5 inputs and outputs
Pin No. Signal
Function
Specification
Lenze
Alternatively
adjustable via
SDC
1
+AIN0 (DIN0) Analog input 0
differential
(speed setpoint, current
setpoint)
DIN0
Input voltage
−10 V ... +10 V
Overvoltage protection
−30 V ... +30 V
2
−AIN0 (DIN1)
DIN1
Input impedance
> 20 k
W
Resolution
12 Bit
3
+AIN1 (DIN2) Analog input 1
differential
DIN2
Offset error
< ± 50 mV
Gain error
< 5 %
4
−AIN1 (DIN3)
DIN3
Limiting frequency
~ 1 kHz
5
+AMON0
Analog monitors
output of internal quantities (current, speed,
etc.)
Output signal
0 V ... 10 V,
max. 2 mA
6
+AMON1
7
GND
Reference potential for pin 1 ... 6, pin 8 ... 16
8
DIN4
Digital input 4
Rated voltage
+24V DC
9
DIN5
Digital input 5
Voltage range
0 ... +30 V DC
10
DIN6
Digital input 6
HIGH signal
> +8 V DC
11
DIN7
Digital input 7
LOW signal
< +4 V DC
12
DIN8
Digital input 8
Input impedance
> 4.7 k
W
13
DIN9
Digital input 9
(controller enable / delete error)
Switching delay
(LOW−HIGH transmission)
< 1 ms
14
DOUT0
Digital output 0
(ready for operation)
Output voltage
0 V / 24 V
LOW signal
0 ... 4 V DC
HIGH signal
18 V ... 30 V
15
DOUT1
Digital output 1
Output current
max. 10 mA
Load impedance
> 2.2 k
W
16
DOUT2
Digital output 2
Switching delay
(LOW−HIGH transmission)
< 1 ms
Terminal data
Max. conductor cross−section
Tightening torque
Screw drive
Cable
[mm
2
]
[AWG]
[Nm]
[lb−in]
Flexible
7 mm
2.5
12
0.5 ... 0.6
4.4 ... 5.3
Slot 0.6 x 3.5
With wire end
ferrule