Technical data
Rated data
16
GHB 13.0001−EN EN 3.0
3.2
Rated data
Supply voltage
Rated voltage
24V DC
48V DC
Permissible range
19.2 V DC − 0 % ... 57.6 V DC + 0 %
Supply current at rated power
approx. 13 A
Max. supply current
35 A
Rated power
310 W
620 W
Efficiency
up to 95 %
PWM frequency (switchable)
10 kHz
20 kHz
10 kHz
20 kHz
Rated output current
0 ... 13 A
eff
0 ... 10 A
eff
0 ... 13 A
eff
0 ... 10 A
eff
Output surge current for 2 s
32 A
eff
25 A
eff
32 A
eff
25 A
eff
Rated output voltage
0 ... 14 V
eff
0 ... 27 V
eff
Output frequency
0 ... 200 Hz
Control voltage
1)
24 V DC ±20 %
Control current
min. 0.25 A (control section only)
max. 1.5 A (all outputs connected)
Brake chopper switching threshold
On
approx. 63 V DC
Off
approx. 60 V DC
Overvoltage monitoring switching threshold
approx. 70 V DC
Internal brake resistor
Resistance R
17
W
Permanent power P
N
10 W
Peak power P
pulse
200 W for 50 ms
External brake resistor
Resistance R
> 5
W
Permanent power P
N
10 ... 600 W
Motor holding brake
24 V / 1 A
Positioning range
± 2
19
revolutions
Savable positions
64
Scanning times of the control loops
Current controller
100
m
s
Speed controller
200
m
s
Position controller
400
m
s
1)
Observe minimum voltage of the brake!
efesotomasyon.com - Lenze