4
Technical data
4.1
General data and operating conditions
16
Lenze · Inverter Drive 8400 motec (PROFINET® option) · DMS 5.0 EN · 02/2019 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4
Technical data
4.1
General data and operating conditions
"Inverter Drives 8400 motec" hardware manual
Here you will find the
ambient conditions
and information on the
electromagnetic
compatibility (EMC)
that also apply to the Communication Unit.
Range
Values
Order designation
• E84DGFCRxNx (PROFINET)
• E84DGFCRxJx (PR Safety)
Communication profile
PROFINET
Communication medium
S/FTP (Screened Foiled Twisted Pair, ISO/IEC 11801 or EN 50173), CAT 5e
Interface for communication
• PROFINET port 1: M12 socket, 5-pole, D-coded
• PROFINET port 2: M12 socket, 5-pole, D-coded
Network topology
Tree, star, and line
Type of node
I/O device with real time (RT) communication properties
Number of device nodes
Max. 255 in the subnetwork
Max. cable length between two
nodes
100 m
PNO identification number
0x0106
Device identification (Device ID)
0x8440
Baud rate
100 Mbps
Switching method
"Store and forward"
Switch latency
Approx. 125
μ
s at max. frame length
External voltage supply
• U = 24 V DC (20 V - 0 % ... 29 V + 0 %)
• I
max
= 120 mA
Conformities, approvals
• CE
• UR / cUR
(see also hardware manual)