Communication manual 8400 motec PROFIBUS
Parameter data transfer
DRIVECOM parameter data channel (DP-V0)
48
L
EDS84DMOTPBUS EN 3.0 - 11/2011
9.2.6
Error codes
The following error messages may appear:
Byte 8
Byte 7
Byte 6
Byte 5
Meaning
Error 1
Error 2
Error 3
Error 4
0x06
0x03
0x00
0x00
No right to access
0x06
0x05
0x11
Invalid subindex
0x06
0x05
0x12
Data length too large
0x06
0x05
0x13
Data length too small
0x06
0x07
0x00
Object does not exist
0x06
0x08
0x00
Data types do not comply with each other
0x08
0x00
0x00
Request cannot be executed
0x08
0x00
0x20
Request cannot be executed at the moment
0x08
0x00
0x22
Request cannot be executed due to the device status / The
parameter can only be changed in the case of a controller inhibit
0x08
0x00
0x30
Out of value range
0x08
0x00
0x31
Parameter value too high
0x08
0x00
0x32
Parameter value too low
0x08
0x00
0x80
Hardware error