Communication manual 8400 motec PROFIBUS
Process data transfer
Digital and analog input information
40
L
EDS84DMOTPBUS EN 3.0 - 11/2011
8.3
Digital and analog input information
In addition to the process data, digital and analog input information can also be queried.
The signals are set permanently to 2 additional data words which must be parameterised
correspondingly in the HW manager.
Word
Bit
Function
Values / states
1
0
Analog input value (0 ... 10 V) 10 V = 1000
dec
(1111101000
bin
)
...
9
10
Digital input 3
0: Closed / not active
1: Open / active
11
Digital input 4
0: Closed / not active
1: Open / active
12
Digital input 5
0: Closed / not active
1: Open / active
13
Reserved
14
I/O status
0: I/O data are invalid.
1: I/O data are valid.
15
Drive status
0: Controller is 'offline'.
1: Controller ist 'online'.
2
0
RFR (controller enable)
0: Controller is enabled.
1: Controller is not enabled (inhibited).
1
Digital input 1
0: Closed / not active
1: Open / active
2
Digital input 2
0: Closed / not active
1: Open / active
3
Digital input 3
0: Closed / not active
1: Open / active
4
Digital input 4
0: Closed / not active
1: Open / active
5
Digital input 5
0: Closed / not active
1: Open / active
6
Reserved
...
13
14
I/O status
0: I/O data are invalid.
1: I/O data are valid.
15
Drive status
0: Controller is 'offline'.
1: Controller ist 'online'.
Содержание E84DGFCp Series