Parameter reference
Parameters relevant for AS-i communication
66
Lenze · Decentralised frequency inverter 8400 motec (AS-Interface option) · EDS84DMOTASI EN 5.0 - 02/2019
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13214
C13220
Parameter | Name:
C13214 | CTT2 block parameter transfer: Read parameter block configuration
Data type: INTEGER_32
Index: 11361 = 0x2C61
CTT2 block parameter transfer Read mode (
Setting range
(min. value | unit | max. value)
0.000
16000.000
Subcodes
Lenze setting
Info
C13214/1
50.000
ReadParamBlock:Index_1
C13214/2
51.000
ReadParamBlock:Index_2
C13214/3
53.000
ReadParamBlock:Index_3
C13214/4
54.000
ReadParamBlock:Index_4
C13214/5
58.000
ReadParamBlock:Index_5
C13214/6
61.000
ReadParamBlock:Index_6
C13214/7
64.001
ReadParamBlock:Index_7
C13214/8
98.000
ReadParamBlock:Index_8
C13214/9
133.000
ReadParamBlock:Index_9
C13214/10
137.000
ReadParamBlock:Index_10
C13214/11
150.000
ReadParamBlock:Index_11
C13214/12
155.000
ReadParamBlock:Index_12
C13214/13
158.000
ReadParamBlock:Index_13
C13214/14
443.001
ReadParamBlock:Index_14
C13214/15
444.001
ReadParamBlock:Index_15
C13214/16
179.000
ReadParamBlock:Index_16
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Scaling factor: 1000
Parameter | Name:
C13220 | Display: Last data to master
Data type: UNSIGNED_16
Index: 11355 = 0x2C5B
Display of the last data transmitted from the communication unit to the master.
Value is bit-coded:
Bit 0 D0
Bit 1 D1
Bit 2 D2
Bit 3 D3
Bit 4 PR0
Bit 5 PR1
Bit 6 PR2
Bit 7 PR3
Bit 8 Reserved
... ...
Bit 15 Reserved
Subcodes
Info
C13220/1
Last data to master from slave 1
C13220/2
Last data to master from slave 2
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM