Module internal/watchdog error [0x01bc6010]
Drive PDO communication timeout [0x01bc6011]
Module offline [0x01bc6100]
Module PDO communication timeout [0x01bc6101]
Response
(Lenze setting printed in bold)
/
(
adjustable response)
None
System fault
Fault
Trouble
Quick stop by trouble
Warning locked
warning
Information
Cause
Remedy
Device internal MCU error
• Switch the voltage supply of the Inverter Drive 8400
motec and the AS-i network off and on again.
• If this error continues to occur, please contact the
Lenze Service. (if required, the Communication Unit
must be replaced.)
Response
(Lenze setting printed in bold)
/
(
adjustable response)
None
System fault
Fault
Trouble
Quick stop by trouble
Warning locked
warning
Information
Cause
Remedy
Voltage supply of the Inverter Drive 8400 motec
interrupted.
• Check wiring and terminals.
• Check whether the Inverter Drive 8400 motec is
addressable via the diagnostics interface.
• Switch off and on again the voltage supply of the
Inverter Drive 8400 motec.
• If this error continues to occur, please contact the
Lenze Service. (if required, the Communication Unit
must be replaced.)
Response
(Lenze setting printed in bold)
/
(
adjustable response)
None
System fault
Fault
Trouble
Quick stop by trouble
Warning locked
warning
Information
Cause
Remedy
• Device internal MCU error
• AS-i voltage supply interrupted.
• Connection between the Communication Unit and
the Drive Unit defective.
• Check wiring and terminals.
• Switch the voltage supply of the AS-i network off and
on again.
• If this error continues to occur, please contact the
Lenze Service. (if required, the Communication Unit
must be replaced.)
Response
(Lenze setting printed in bold)
/
(
adjustable response)
None
System fault
Fault
Trouble
Quick stop by trouble
Warning locked
warning
Information
Cause
Remedy
• AS-i voltage supply interrupted.
• Connection between the Communication Unit and
the Drive Unit defective.
• Check wiring and terminals.
• Switch the voltage supply of the AS-i network off and
on again.
• If this error continues to occur, please contact the
Lenze Service. (if required, the Communication Unit
must be replaced.)