Process data transfer
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8
Process data transfer
• Process data are transmitted via the process data channel.
• The process data serve to control the inverter.
• The transmission of process data is time-critical.
• Process data are cyclically transferred between the master and the slaves participating in the
fieldbus (continuous exchange of current input and output data).
• The master can directly access the process data. In the PLC, for instance, the data are directly
assigned to the I/O area.
• Process data are not saved in the inverter.
• Process data are e.g. setpoints, actual values, control words, and status words.
Note!
Observe the direction of the information flow.
• Process input data (Rx data):
Process data from the inverter (slave) to the host (master)
• Process output data (Tx data):
Process data from the host (master) to the inverter (slave)