Commissioning
Speed control
Parameterising of a process data object (TPDO and RPDO)
6
62
KHB 13.0003-EN 2.0
No. Description
Identifier Control
field
Command
code
Index
Subindex Data 1 Data 2 Data 3 Data 4
Data
length
Low
byte
High
byte
1
Network management (NMT)
For parameterising the PDO, the
network management is set to
Pre-operational (80
h
).
00
2
80
00
00
00
00
00
00
00
2
Deactivating the RPDO
The RPDO is deactivated by
setting bit 31.
601
8
23
00
14
01
01
02
00
80
3
Deleting the number of objects
For changing the object
mapping, the number of objects
(number_of_mapped_objects)
must be set to zero.
601
5
2F
00
16
00
00
00
00
00
4
Parameterising the first object
to be mapped
Here, the index of the object to
be mapped (first_mapped_
object) and the length of the
corresponding variable type
must be indicated. The first
object to be mapped is the
setpoint speed (index 60FF_00
h
)
with a length of 32 bits (20
h
).
601
8
23
00
16
01
20
00
FF
60
5
Defining the number of objects
In this example, one mapped
object (setpoint speed) is to be
transmitted (number_of_
mapped_objects).
601
5
2F
00
16
00
01
00
00
00
6
Parameterising the transmission
mode
The PDO transmission is
event-controlled and depends
on the transmission cycle time
(entry FF
h
in the transmission_
type).
601
5
2F
00
14
02
FF
00
00
00
7
Activating the RPDO
The PDO is activated by
resetting bit 31.
601
8
23
00
14
01
01
02
00
00
8
Network management (NMT)
For parameterising the PDO, the
network management is set to
Operational (01
h
).
00
2
01
00
00
00
00
00
00
00
Tab. 3
Example parameterisation of a receive PDO