Configuration
2−74
l
EDSVF9383V−EXT EN 2.0
2.4.17
Conversion (CONV)
These FBs convert analog signals or convert signals into another signal type. The conversion factor
as numerator and denominator is calculated using residual value processing.
CONV1
CONV1
CONV1−OUT
CONV1−IN
C0943
C0942
C0940
C0941
Fig. 2−57
Conversion (CONV1)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
CONV1−IN
a
C0943
dec [%]
C0942
1
1000
CONV1−OUT
a
−
−
−
−
−
Limited to ±199.99 %
This FB is used to multiply analog signals with a specified factor. The calculation is done according
to the following formula:
CONV1−OUT
+
CONV1−IN
@
C0940
C0941
Example:
l
You want to multiply an analog signal with 1.12.
l
For this, enter C0940 = 112 and C0941 = 100.
CONV2
CONV2
CONV2−OUT
CONV2−IN
C0948
C0947
C0945
C0946
Fig. 2−58
Conversion (CONV2)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
CONV2−IN
a
C0948
dec [%]
C0947
1
1000
CONV2−OUT
a
−
−
−
−
−
Limited to ±199.99 %
This FB is used to multiply analog signals with a specified factor. The calculation is done according
to the following formula:
CONV2−OUT
+
CONV2−IN
@
C0945
C0946
Содержание 9300 vector Series
Страница 8: ...Preface Definition of notes used 1 6 l EDSVF9383V EXT EN 2 0...
Страница 188: ...Application examples Centre winder with internal diameter calculation 3 18 l EDSVF9383V EXT EN 2 0...
Страница 192: ...Signal flow charts Speed control 4 4 l EDSVF9383V EXT EN 2 0 Fig 4 1 Basic configuration 1000 speed control sheet 1...
Страница 205: ...Signal flow charts Step control 4 17 l EDSVF9383V EXT EN 2 0 Fig 4 13 Basic configuration 2000 step control sheet 1...
Страница 211: ...Signal flow charts Torque control 4 23 l EDSVF9383V EXT EN 2 0 Fig 4 17 Basic configuration 4000 torque control sheet 1...