Configuration
2−129
l
EDSVF9383V−EXT EN 2.0
2.4.44
Motor potentiometer (MPOT)
This FB is used as an alternative setpoint source which is triggered by two inputs.
C0260
C0262
MPOT1
MPOT1−OUT
MPOT
CRTL
C0269/1
C0269/2
C0269/3
MPOT1−DOWN
MPOT1−INACT
MPOT1−UP
C0264
C0263
C0261
C0267/1
C0268
C0267/2
C0265
Fig. 2−101
Motor potentiometer (MPOT1)
Signal
Source
Note
Name
Type
DIS
DIS format
CFG
List
Lenze
MPOT1−UP
d
C0269/1
bin
C0267/1
2
1000
−
MPOT1−INACT
d
C0269/3
bin
C0268
2
1000
−
MPOT1−DOWN
d
C0269/2
bin
C0267/2
2
1000
−
MPOT1−OUT
a
−
−
−
−
−
Range of functions
l
Control of the motor potentiometer
l
Deactivation of the motor potentiometer
l
Initialization of the motor potentiometer
2.4.44.1
Control of the motor potentiometer
l
MPOT1−UP = HIGH
– The motor potentiometer approaches its upper limit.
l
MPOT1−DOWN = HIGH
– The motor potentiometer approaches its lower limit.
l
MPOT1−UP = LOW and MPOT1−DOWN = LOW or
MPOT1−UP = HIGH and MPOT1−DOWN = HIGH:
– The motor potentiometer does not change its output signal.
Tir
Tir
Tir
Tif
MPOT1
−
UP
MPOT1
−
DOWN
C0260
C0261
0
+
−
MPOT1
−
OUT
Fig. 2−102
Control signals of the motor potentiometer
Содержание 9300 vector Series
Страница 8: ...Preface Definition of notes used 1 6 l EDSVF9383V EXT EN 2 0...
Страница 188: ...Application examples Centre winder with internal diameter calculation 3 18 l EDSVF9383V EXT EN 2 0...
Страница 192: ...Signal flow charts Speed control 4 4 l EDSVF9383V EXT EN 2 0 Fig 4 1 Basic configuration 1000 speed control sheet 1...
Страница 205: ...Signal flow charts Step control 4 17 l EDSVF9383V EXT EN 2 0 Fig 4 13 Basic configuration 2000 step control sheet 1...
Страница 211: ...Signal flow charts Torque control 4 23 l EDSVF9383V EXT EN 2 0 Fig 4 17 Basic configuration 4000 torque control sheet 1...