8400 motec | Software Manual
Parameter reference
Parameter list | C02842
304
L
Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
C02842
C02843
Parameter | Name:
C02842 | FreqInxx: Offset
Data type: INTEGER_16
Index: 21733
d
= 54E5
h
From version 02.00.00
Offset for digital frequency input
Using DI1 and DI2 as frequency inputs
Setting range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Lenze setting
Info
C02842/1
0.00 %
FreqIn12: Offset
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C02843 | FreqInxx: Gain
Data type: INTEGER_16
Index: 21732
d
= 54E4
h
From version 02.00.00
Gain for digital frequency input
Using DI1 and DI2 as frequency inputs
Setting range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Lenze setting
Info
C02843/1
100.00 %
FreqIn12: Gain
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100