Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
L
281
8400 motec | Software Manual
Parameter reference
Parameter list | C00633
C00633
C00634
Parameter | Name:
C00633 | L_NSet_1: Min.InhibitFrq.
Data type: INTEGER_16
Index: 23942
d
= 5D86
h
Minimum limit values for the speed blocking zones
• Selection of the minimum limit values for the blocking zones in which the speed must not be constant.
Setting range
(min. value | unit | max. value)
0.0
%
199.9
Subcodes
Lenze setting
Info
C00633/1
0.0 %
: Blocking speed 1 min
C00633/2
0.0 %
: Blocking speed 2 min
C00633/3
0.0 %
: Blocking speed 3 min
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00634 | L_NSet_1: wState
Data type: UNSIGNED_16
Index: 23941
d
= 5D85
h
FB
: Bit-coded status display
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 No blocking zone active
"1"
≡
No blocking zone set for constant speeds
Bit 1 Blocking zone 1 active
"1"
≡
Suppression of constant speed characteristics
within the limits of blocking zone 1
Bit 2 Blocking zone 2 active
"1"
≡
Suppression of constant speed characteristics
within the limits of blocking zone 2
Bit 3 Blocking zone 3 active
"1"
≡
Suppression of constant speed characteristics
within the limits of blocking zone 3
Bit 4 Jog in blocking zone
"1"
≡
A ramp is used to keep the speed setpoint within a
speed blocking zone
Bit 5 MaxLimit active
"1"
≡
Speed setpoint is at the maximum speed limit
Bit 6 MinLimit active
"1"
≡
Speed setpoint is at the minimum speed limit
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Содержание 8400 motec Series