Parameter reference
Parameter list | C00446
C00446
C00462
C00463
C00466
C00467
C00469
Parameter | Name:
C00446 | FreqInxx_nOut_a
Data type: INTEGER_16
Index: 24129
d
= 5E41
h
From version 02.00.00
Display of the frequency inputs signals that have been fed into the application.
Using DI1 and DI2 as frequency inputs
Display range
(min. value | unit | max. value)
-199.9
%
199.9
Subcodes
Info
C00446/1
FreqIn12_nOut_a
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00462 | Keypad/PC: Setpoint control
Data type: UNSIGNED_16
Index: 24113
d
= 5E31
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00463 | Keypad:
Data type: INTEGER_32
Index: 24112
d
= 5E30
h
Setting range
(min. value | unit | max. value)
0.000
16000.000
Subcodes
Lenze setting
Info
C00463/1
729.001
Keypad: Speed setpoint parameter
C00463/2
56.002
Keypad: Bargraph code parameter
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1000
Parameter | Name:
C00466 | Keypad: Default parameter
Data type: INTEGER_32
Index: 24109
d
= 5E2D
h
Setting of the default parameter for the keypad
Setting range
(min. value | unit | max. value)
Lenze setting
0
65535
51
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00467 | Keypad: Default welcome screen
Data type: INTEGER_32
Index: 24108
d
= 5E2C
h
Selection of the welcome screen of the keypad
Selection list
(Lenze setting printed in bold)
0 Main menu
1 Parameter list
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00469 | Keypad: STOP key function
Data type: INTEGER_32
Index: 24106
d
= 5E2A
h
Selection of the function to be executed when the STOP key on the keypad is pressed
Selection list
(Lenze setting printed in bold)
Info
0 No function
STOP key has no function
1 Inhibit controller
STOP key sets a controller inhibit in the drive
2 Activate quick stop
STOP key triggers a quick stop in the drive
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1