Technical Data
3-6
821XKlimaBA0399
3.3.2
Types 8215 to 8218
150 % overload
Type
8215
8216
8217
8218
Mains voltage
V
rated
[V]
320V - 0%
$
V
rated
$
510V + 0%;
45Hz
¡
65Hz
á
0%
Alternative DC supply
V
G
[V]
450V - 0%
$
V
DC
$
715V +
0%
Mains current
with mains filter/mains choke
without mains filter/mains choke
I
mains
[A]
I
mains
[A]
8.8
13.2
12.0
18.0
15.0
22.5
20.5
--
Data for mains operation with 3 AC/400V/50 Hz/60 Hz; 450V
$
V
DC
$
650V or
3 AC/460V/50 Hz/60Hz; 460V
$
V
DC
$
725V
400V
460V
400V 460V 400V 460V 400V 460V
Motor power (4 pole ASM)
off 4kHz/8kHz*
P
rated
[kW]
4.0
5.5
5.5
7.5
7.5
11.0
11.0
15.0
Motor power (4 pole ASM)
off 4kHz/8kHz*
P
rated
[hp]
5.4
7.5
7.5
10.0
10.0
15.0
15.0
20.0
Output power U, V, W
off 4 kHz/8 kHz*
S
rated8
[kVA]
6.5
7.5
9.0
10.3
11.4
13.7
16.3
19.5
Output power + U
G
, -U
G
1)
P
DC
[kW]
1.0
1.0
0.0
0.0
3.9
3.9
0.0
0.0
Output
current
4 kHz*
I
rated4
[A]
9.4
9.4
13.0
13.0
16.5
16.5
23.5
23.5
Output
current
8 kHz*
I
rated8
[A]
9.4
9.4
13.0
13.0
16.5
16.5
23.5
23.5
12 kHz*
I
rated12
[A]
7.9
7.4
10.9
10.3
13.9
13.0
19.7
18.5
16 kHz*
I
rated16
[A]
7.0
6.6
9.7
9.1
12.3
11.6
17.6
16.5
noise optimized
4 kHz*
I
rated4
[A]
9.4
8.9
13.0
12.3
16.5
15.6
23.5
22.1
noise optimized
8 kHz*
I
rated8
[A]
8.0
7.6
11.1
10.5
14.1
13.3
20.0
18.8
noise optimized
12 kHz*
I
rated12
[A]
7.5
7.0
10.4
9.7
13.2
12.4
18.8
17.6
noise optimized
16 kHz*
I
rated16
[A]
6.1
5.6
8.4
7.8
10.7
9.9
15.3
14.1
4 kHz*
I
rated max4
[A]
14.1
14.1
19.5
19.5
24.8
24.8
35.3
35.3
8 kHz*
I
rated max8
[A]
14.1
14.1
19.5
19.5
24.8
24.8
35.3
35.3
12 kHz*
I
rated max12
[A]
11.9
11.1
16.4
15.4
20.8
19.6
29.6
27.9
16 kHz*
I
rated max16
[A]
10.6
9.8
14.6
13.6
18.6
17.4
26.5
24.7
noise optimized
4 kHz*
I
rated max4
[A]
14.1
13.3
19.5
18.3
24.8
23.4
35.3
55.1
noise optimized
8 kHz*
I
rated max8
[A]
12.0
11.3
16.6
15.6
21.1
19.9
30.0
28.2
noise optimized
12 kHz*
I
rated max12
[A]
11.3
10.6
15.6
14.6
19.8
18.8
28.2
26.4
noise optimized
16 kHz*
I
rated max16
[A]
9.1
8.5
12.7
11.7
16.1
14.9
22.9
21.1
Power loss
(Operation with I
rated
)
P
v
[W]
150
200
280
400
*
No dynamic chopper-frequency lowering of the inverter
For all other data see chapter 3.2.3.
1)
This power can be additionally obtained when operating a matching motor
2)
The currents applyto a periodical load cycle with 1 minute overcurrent with the current mentioned here
and 2 minutes base load with 75% I
Nx
.
Show/Hide Bookmarks
Содержание 8210 HVAC Series
Страница 52: ...Commissioning 5 14 821XKlimaBA0399 Show Hide Bookmarks...
Страница 62: ...Commissioning 5 24 821XKlimaBA0399 Show Hide Bookmarks...
Страница 64: ...During operation 6 2 821XKlimaBA0399 Show Hide Bookmarks...
Страница 78: ...Configuration 7 14 821XKlimaBA0399 Show Hide Bookmarks...
Страница 84: ...Troubleshooting and fault elimination 8 6 821XKlimaBA0399 Show Hide Bookmarks...
Страница 88: ...Accessories 9 4 821XKlimaBA0399 Show Hide Bookmarks...
Страница 92: ...Index 10 4 821XKlimaBA0399 Show Hide Bookmarks...
Страница 93: ...Index 821XKlimaBA0399 10 5 Show Hide Bookmarks...
Страница 94: ...Index 10 6 821XKlimaBA0399 Show Hide Bookmarks...