Commissioning
Important codes for quick commissioning
145
EDK82EV222 DE/EN/FR 13.0
Important codes for quick commissioning
The following table describes the codes mentioned in the commissioning examples. A description of
all codes can be found in the system manual, chapter "Function library".
How to read the code table
Column
Abbreviation
Meaning
Code
Cxxxx
Code Cxxxx
l
The parameter value of the code can be
defined differently within each parameter set
l
The parameter value is accepted immediately
(ONLINE)
1
Subcode 1 of Cxxxx
2
Subcode 2 of Cxxxx
*
Parameter value of the code is the same for all parameter sets and can be
changed in parameter set 1
Keypad E82ZBC
Changed parameter of the code or subcode will
be accepted after pressing
Keypad XT
EMZ9371BC
Changed parameter of the code or subcode will
be accepted after pressing
!
Keypad E82ZBC
Changed parameter of the code or subcode will
be accepted after pressing
if the controller is
inhibited
Keypad XT
EMZ9371BC
Changed parameter of the code or subcode will
be accepted after pressing
if the
controller is inhibited
(A)
Code, subcode or selection only available for operation with application
I/O
uSEr
Code is contained in the Lenze setting in the USER menu
Designation
Name of the code
Lenze
Lenze setting (value at delivery or after restoring the delivery status with
C0002)
à
Further information can be obtained from the "IMPORTANT" column
Selection
1
{%}
99 Min. value
{unit} max. value
IMPORTANT
−
Brief, important explanations
Содержание 8200 vector series