![Lenze 8200 vector E82CV153K4B Скачать руководство пользователя страница 186](http://html1.mh-extra.com/html/lenze/8200-vector-e82cv153k4b/8200-vector-e82cv153k4b_mounting-instructions_1882275186.webp)
Troubleshooting and fault elimination
Fault elimination
Fault messages
186
EDK82EV903 DE/EN/FR 5.1
8.3.2
Fault messages
Keypad
PC
1)
Fault
Cause
Remedy
noer
0
No fault
−
−
ccr
"
71
System fault
Strong interference injections on the
control cables
Shield control cables
Earth loops in the wiring
ce0
"
61
Communication error
on AIF
(configurable in C0126)
Faulty transmission of control
commands via AIF
Insert the communication module firmly
into the diagnosis terminal
ce1
"
62
Communication error
on CAN−IN1 with sync
control
CAN−IN1 object receives faulty data, or
communication is interrupted
l
Check plug connection bus module
ó
FIF
l
Check transmitter
l
Increase monitoring time in C0357/1, if
necessary
ce2
"
63
Communication error
on CAN−IN2
CAN−IN2 object receives faulty data, or
communication is interrupted
l
Check plug connection bus module
ó
FIF
l
Check transmitter
l
Increase monitoring time in C0357/2, if
necessary
ce3
"
64
Communication error
on CAN−IN1 with event
or time control
CAN−IN1 object receives faulty data, or
communication is interrupted
l
Check plug connection bus module
ó
FIF
l
Check transmitter
l
Increase monitoring time in C0357/3, if
necessary
ce4
"
65
BUS−OFF
(many communication
errors occurred)
Controller has received too many faulty
telegrams via the system bus and has
been disconnected from the bus
l
Check bus termination
l
Check shield connection of the cables
l
Check PE connection
l
Check bus load, reduce the baud rate, if
necessary
ce5
"
66
CAN time−out
(configurable in C0126)
For remote parameterisation via the
system bus (C0370):
Slave does not respond.
Communication monitoring time has
been exceeded
l
Check wiring of the system bus
l
Check system bus configuration
For operation with application I/O:
Parameter set change−over has been
parameterised incorrectly
The "parameter set change−over" signal
(C0410/13, C0410/14) must be connected to
the same source in all parameter sets
For operation with module on FIF:
Internal error
Contact Lenze
ce6
"
67
System bus (CAN)
function module on FIF
has the "Warning" or
"BUS−OFF" status
(configurable in C0126)
CAN controller reports "Warning" or
"BUS−OFF" status
l
Check bus termination
l
Check shield connection of the cables
l
Check PE connection
l
Check bus load, reduce the baud rate, if
necessary
ce7
"
68
Communication error
during remote
parameterisation via
system bus (C0370)
(configurable in C0126)
Node does not respond or is not
available
l
Check bus termination
l
Check shield connection of the cables
l
Check PE connection
l
Check bus load, reduce the baud rate, if
necessary
For operation with application I/O:
Parameter set change−over has been
parameterised incorrectly
The "parameter set change−over" signal
(C0410/13, C0410/14) must be connected to
the same source in all paramerter sets
EEr
"
91
External fault (TRIP−SET) A digital signal assigned to the TRIP−Set
function is activated
Check external encoder
ErP0
...
ErP19
"
−
Communication abort
between keypad and
standard device
Various
Contact Lenze
Содержание 8200 vector E82CV153K4B
Страница 3: ...E82EV153K4B E82EV303K4B 8200vec292 E82EV453K4B E82EV553K4B 8200vec311...
Страница 97: ...Fehlersuche und St rungsbeseitigung St rungsmeldungen zur cksetzen 8 97 EDK82EV903 DE EN FR 5 1...
Страница 285: ......
Страница 286: ...E82EV753K4B E82EV903K4B 8200vec312...
Страница 287: ......