![Lenze 8200 vector E82CV153K4B Скачать руководство пользователя страница 126](http://html1.mh-extra.com/html/lenze/8200-vector-e82cv153k4b/8200-vector-e82cv153k4b_mounting-instructions_1882275126.webp)
Mechanical installation
Standard devices with a power of 45 kW
Mounting with fixing brackets (standard)
126
EDK82EV903 DE/EN/FR 5.1
2
3
1
³
100 mm
a
c
e
k
b1
d2
d1
d
³
100 mm
l
L
m
g
a
M 8
M 8
max. 15 mm
g
f
e
c1
18 Nm
159.3 lb-in
0
³
50 mm
³
50 mm
8200vec296
Loosen both screws to be able to remove the housing cover. The assembly kit is located under
the housing cover.
Installation of mounting angles
Dimensions
Arrange the controllers side by side with spacing to be able to disassemble the eyebolts.
Dimensions [mm]
8200 vector
a
b1
c
c1
d
d1
d2
e
1)
g
k
m
E82EV453K4B2xx
340
510
283
28.5
580
38
532
285
11
28
18
1)
If the function module is attached: observe mounting clearance and cable bending radius. The terminals of function
modules in PT design protrude above the housing by 8 mm.