Air baffle
Figure 80. Air baffle removal
To remove the air baffle, complete the following steps:
Step 1.
Read the safety information that begins on page “Safety” on page v and “Installation guidelines” on
page 297.
Step 2.
Turn off the server and peripheral devices and disconnect the power cords and all external cables
(see “Turning off the server” on page 46).
Step 3.
Remove the top cover (see “Removing the top cover” on page 149).
Step 4.
Remove PCI riser-card assemblies, if needed (see “Removing a riser-card assembly” on page 186).
Step 5.
Disconnect the RAID adapter battery/flash power module cables, if needed.
Step 6.
Place your fingers under the back of the top of the air baffle; then, lift the air baffle out of the server.
Attention:
For proper cooling and airflow, replace the air baffle before you turn on the server.
Operating the server with the air baffle removed might damage server components.
Step 7.
If you are instructed to return the air baffle, follow all of the packaging instructions, and use any
packaging materials for shipping that are supplied to you.
Replacing the air baffle
Use this information to replace the air baffle.
To replace the air baffle, complete the following steps:
Step 1.
Read the safety information that begins on page “Safety” on page v and “Installation guidelines” on
page 297.
Step 2.
Turn off the server and peripheral devices and disconnect the power cords and all external cables.
Step 3.
Remove the top cover (see “Removing the top cover” on page 149).
Step 4.
Align the air baffle tabs with the baffle slots on both sides of the chassis; then, lower the air baffle
into the server. Press the air baffle down until it is securely seated.
Installing, removing, and replacing components
153
Содержание x3650 M5
Страница 1: ...Lenovo System x3650 M5 Installation and Service Guide Machine Type 8871 ...
Страница 47: ...Figure 35 System board switches jumpers and buttons Chapter 1 The System x3650 M5 server 35 ...
Страница 60: ...48 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 80: ...68 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 124: ...112 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 146: ...134 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 1322: ...1310 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 1329: ...People s Republic of China Class A electronic emission statement Taiwan Class A compliance statement Appendix E Notices 1317 ...
Страница 1330: ...Taiwan BSMI RoHS declaration 1318 Lenovo System x3650 M5 Installation and Service Guide ...
Страница 1339: ......
Страница 1340: ......