![Lenovo x3550 M4 Скачать руководство пользователя страница 74](http://html.mh-extra.com/html/lenovo/x3550-m4/x3550-m4_installation-and-service-manual_203258074.webp)
Figure 46. ServeRAID M5110 adapter cable routing
Note:
When you restart the server, you are prompted to import the existing RAID configuration to the
new ServeRAID adapter.
If you have other devices to install or remove, do so now. Otherwise, go to “Completing the installation”
on page 89.
Installing the ServeRAID adapter memory module
Use this information to install the ServeRAID adapter memory module.
To install the ServeRAID adapter memory module, complete the following steps:
Step 1.
Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 31.
Step 2.
Turn off the server and peripheral devices and disconnect all power cords.
Step 3.
Remove the cover (see “Removing the cover” on page 34).
Step 4.
Remove the ServeRAID SAS/SATA controller (see “Removing a ServeRAID SAS/SATA controller”
on page 230).
Step 5.
Align the memory module with the connector on the ServeRAID adapter and push it into the
connector until it is firmly seated.
60
System x3550 M4 Installation and Service Guide
Содержание x3550 M4
Страница 1: ...System x3550 M4 Installation and Service Guide Machine Type 7914 ...
Страница 6: ...iv System x3550 M4 Installation and Service Guide ...
Страница 178: ...164 System x3550 M4 Installation and Service Guide ...
Страница 322: ...308 System x3550 M4 Installation and Service Guide ...
Страница 828: ...814 System x3550 M4 Installation and Service Guide ...
Страница 986: ...972 System x3550 M4 Installation and Service Guide ...
Страница 990: ...976 System x3550 M4 Installation and Service Guide ...
Страница 1005: ......
Страница 1006: ......