Lenovo x3530 M4 Скачать руководство пользователя страница 1

Lenovo System x3530 M4
Installation and Service Guide

Machine Type:

7160

Содержание x3530 M4

Страница 1: ...Lenovo System x3530 M4 Installation and Service Guide Machine Type 7160 ...

Страница 2: ...d User s Guide on the Lenovo Documentation CD and the Lenovo Warranty Information document that comes with the server Eleventh Edition June 2016 Copyright Lenovo 2015 2016 LIMITED AND RESTRICTED RIGHTS NOTICE If data or software is delivered pursuant to a General Services Administration GSA contract use reproduction or disclosure is subject to restrictions set forth in Contract No GS 35F 05925 ...

Страница 3: ...dc power supply 60 Installing a USB embedded hypervisor flash device 65 Installing a RAID adapter battery remotely in the server 67 Installing an optional 4x2 5 inch hot swap drive backplane 69 Completing the installation 73 Chapter 3 Configuration information and instructions 79 Updating the firmware 79 Configuring UEFI compatible devices 80 Configuring the server 80 Using the ServerGuide Setup a...

Страница 4: ...3 Replacing an adapter 194 Removing hot swap drives 196 Installing hot swap drives 197 Removing a simple swap SATA drive 204 Replacing a simple swap SATA drive 205 Removing a CD DVD drive 206 Installing an optional CD DVD drive 207 Removing the CD DVD cable 210 Replacing the CD DVD cable 211 Removing a fan 212 Replacing a fan 213 Removing a memory module 214 Replacing a memory module 215 Removing ...

Страница 5: ...the DSA memory stress test 784 DSA Nvidia GPU test results 788 Test results for the DSA Nvidia GPU test 788 DSA optical drive test results 794 Test results for the DSA optical drive test 795 DSA system management test results 799 Test results for the DSA system management test 799 DSA tape drive test results 814 Test results for the DSA tape drive test 814 Appendix D Getting help and technical ass...

Страница 6: ...iv Lenovo System x3530 M4 Installation and Service Guide ...

Страница 7: ...en Ennen kuin asennat tämän tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de sécurité Vor der Installation dieses Produkts die Sicherheitshinweise lesen Prima di installare questo prodotto leggere le Informazioni sulla Sicurezza Les sikkerhetsinformasjonen Safety Information før du installerer dette produktet Antes de instalar este produto le...

Страница 8: ...etermine how serious the hazard is and whether you must correct the problem before you work on the product Consider the following conditions and the safety hazards that they present Electrical hazards especially primary power Primary voltage on the frame can cause serious or fatal electrical shock Explosive hazards such as a damaged CRT face or a bulging capacitor Mechanical hazards such as loose ...

Страница 9: ...wer off EPO switch disconnecting switch or electrical outlet so that you can turn off the power quickly in the event of an electrical accident Disconnect all power before you perform a mechanical inspection work near power supplies or remove or install main units Before you work on the equipment disconnect the power cord If you cannot disconnect the power cord have the customer power off the wall ...

Страница 10: ...ables or perform installation maintenance or reconfiguration of this product during an electrical storm Connect all power cords to a properly wired and grounded electrical outlet Connect to properly wired outlets any equipment that will be attached to this product When possible use one hand only to connect or disconnect signal cables Never turn on any equipment when there is evidence of fire water...

Страница 11: ...h as CD ROMs DVD drives fiber optic devices or transmitters are installed note the following Do not remove the covers Removing the covers of the laser product could result in exposure to hazardous laser radiation There are no serviceable parts inside the device Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure...

Страница 12: ...e The device also might have more than one power cord To remove all electrical current from the device ensure that all power cords are disconnected from the power source 1 2 Statement 6 CAUTION If you install a strain relief bracket option over the end of the power cord that is connected to the device you must connect the other end of the power cord to an easily accessible power source Statement 8...

Страница 13: ... this label attached There are no serviceable parts inside these components If you suspect a problem with one of these parts contact a service technician Statement 12 CAUTION The following label indicates a hot surface nearby Statement 26 CAUTION Do not place any object on top of rack mounted devices Statement 27 CAUTION Hazardous moving parts are nearby Copyright Lenovo 2015 2016 xi ...

Страница 14: ...ack cabinet Always install stabilizer brackets on the rack cabinet Always install servers and optional devices starting from the bottom of the rack cabinet Always install the heaviest devices in the bottom of the rack cabinet xii Lenovo System x3530 M4 Installation and Service Guide ...

Страница 15: ...iability For more information see What your server offers on page 8 and Reliability availability and serviceability on page 12 You can obtain up to date information about the server and other IBM server products at http www ibm com systems x At http www ibm com support mysupport you can create a personalized support page by identifying IBM products that are of interest to you From this personalize...

Страница 16: ...e available to provide additional information that is not included in the server documentation To check for updates go to http www ibm com supportportal Record information about the server in the following table Product name System x3530 M4 Machine type 7160 Model number _____________________________________________ Serial number _____________________________________________ The model number and s...

Страница 17: ... device drivers and install the operating system For a list of supported optional devices for the server see http www ibm com systems info x86servers serverproven compat us See the Rack Installation Instructions document on the IBM Documentation CD for complete rack installation and removal instructions The Lenovo Documentation CD The Lenovo Documentation CD contains documentation for the server i...

Страница 18: ...nt a description of the document is displayed under Topic Description To select more than one document press and hold the Ctrl key while you select the documents Click View Book to view the selected document or documents in Acrobat Reader or xpdf If you selected more than one document all the selected documents are opened in Acrobat Reader or xpdf To search all the documents type a word or word st...

Страница 19: ...technical updates might be available to provide additional information that is not included in the server documentation These updates are available from the IBM website To check for updates go to http www ibm com supportportal Notices and statements in this document The caution and danger statements in this document are also in the multilingual Safety Information document which is on the IBMDocume...

Страница 20: ...Fans The server comes standard with four speed controlled fans for one microprocessor configuration Supports up to six fans with two microprocessors installed PCI expansion slots depending on your model Two x8 low profile PCIE 3 0 adapter slots on the system board One x16 x16 mechanically PCIE 3 0 adapter slot One x4 x8 mechanically PCIE 3 0 adapter slot on the optional PCI riser card for an optio...

Страница 21: ...port cloud like workload with no performance degradation acceptable Turbo Off Under no circumstance can any combination of worst case workload and configuration result in system shutdown or design exposure at 40 C 104 F Particulate contamination Attention Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might p...

Страница 22: ...ciency of Internal Ac Dc and Dc Dc Power Supplies Measurement methodology used to determine information in this document ENERGY STAR Servers Version 2 0 Program Requirements ECOVA Generalized Test Protocol for Calculating the Energy Efficiency of Internal Ac Dc and Dc Dc Power Supplies What your server offers The server uses the following features and technologies Active Energy Manager The IBM Act...

Страница 23: ...vice drivers For more information about the ServerGuide Setup and Installation CD see Using the ServerGuide Setup and Installation CD on page 81 IBM Systems Director DVD IBM Systems Director is a platform management foundation that streamlines the way you manage physical and virtual systems in a heterogeneous environment By using industry standards IBM Systems Director supports multiple operating ...

Страница 24: ...ot swap SAS SATA hard disk drives or 3 5 inch simple swap SATA or hot swap SAS SATA hard disk drives With the hot swap feature you can add remove or replace hard disk drives without turning off the server Large system memory capacity The server system board provides 12 DIMM connectors for up to 192 GB of memory The server memory controller supports error correcting code ECC for up to 12 industry s...

Страница 25: ...he system state Remotely accessing the server using the keyboard and mouse from a remote client Mapping the CD or DVD drive diskette drive and USB flash drive on a remote client and mapping ISO and diskette image files as virtual drives that are available for use by the server Uploading a diskette image to the IMM memory and mapping it to the server as a virtual drive For information on product fe...

Страница 26: ...stored in the server the availability of the server when you need it and the ease with which you can diagnose and correct problems Your server has the following RAS features 3 year parts and 3 year labor limited warranty Machine Type 7160 24 hour support center Automatic error retry and recovery Automatic restart on nonmaskable interrupt NMI Automatic restart after a power failure Backup basic inp...

Страница 27: ...ogram load RIPL or dynamic host configuration protocol boot protocol DHCP BOOTP System auto configuring from the configuration menu System error logging POST and IMM Systems management monitoring through the Inter Integrated Circuit I2C protocol bus Uncorrectable error UE detection Upgradeable POST Unified Extensible Firmware Interface UEFI diagnostics IMM firmware and read only memory ROM residen...

Страница 28: ...see the Systems Director Information Center at http pic dhe ibm com infocenter director pubs index jsp topic 2 Fcom ibm director main helps doc 2Ffqm0_main html and the Systems Management web page at http shop lenovo com us en systems solutions which presents an overview of Systems Management and Systems Director Server controls LEDs and power This section describes the controls and light emitting...

Страница 29: ...ation panel on page 15 Operator information panel release button Optional This release button is on the advanced operator information panel Push the blue release button and pull out the light path diagnostics panel to view the light path diagnostics LEDs and buttons See Operator information panel on page 15 Light path diagnostics on page 111 and Light path diagnostics LEDs on page 115 for more inf...

Страница 30: ...y to be turned on You can press the power control button to turn on the server Lit The server is turned on Fading on and off The server is in a reduced power state To wake the server press the power control button or use the IMM web interface See Logging on to the Web interface on page 94 for information on logging on to the IMM web interface Ethernet activity LEDs When any of these LEDs is flashi...

Страница 31: ...panel is available on the top of the advanced operator information panel For additional information about the light path diagnostics and LEDs on the light path diagnostics panel see Light path diagnostics on page 111 and Light path diagnostics LEDs on page 115 0000000000000000000000 0000000000000000000000 0000000000000000000000 0000000000000000000000 0000000000000000000000 0000000000000000000000 0...

Страница 32: ...orrected the server is restarted or a new problem occurs By placing the system error LED indicator in Remind mode you acknowledge that you are aware of the last failure but will not take immediate action to correct the problem Reset button Press this button to reset the server and run the power on self test POST You might have to use a pen or the end of a straightened paper clip to press the butto...

Страница 33: ...00000000000 0000000 000000000 000 000 000 00000000000 00000000000 00000000000 00000000000 0000000 000000000 000 000 000 Figure 9 Rear view of server The following illustrations show the locations of the power supply LEDs for fixed and redundant models respectively on the rear of the server Chapter 1 The System x3530 M4 7160 server 19 ...

Страница 34: ...power supply is supplying adequate dc power to the system During normal operation both the ac and dc power LEDs are lit For any other combination of LEDs see Power supply LEDs on page 119 Power supply error LED Each power supply has an ac power LED and a dc power LED When the power supply error LED is lit it indicates that the power supply has failed Video connector Connect a monitor to this conne...

Страница 35: ... network is limited to 100 Mbps full duplex Server power features When the server is connected to a suitable input source but is not turned on the operating system does not run and all core logic except for the service processor the integrated management module is shut down However the server can respond to requests to the service processor such as a remote request to turn on the server The power ...

Страница 36: ...h on the power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To remove all electrical current from the device ensure that all power cords are disconnected from the power source 1 2 The server can be turned off in any of the following ways You can turn off the server from the operating system if your operating system support...

Страница 37: ...d device can cause system failure because of damaged pins in sockets or connectors loose cabling or loose components 4 Use the best practices to apply current firmware and device driver updates for the server and optional devices To download the IBM System x Firmware Update Best Practices document go to www ibm com support entry portal docdisplay lndocid MIGR 5082923 brandind 5000008 Additional hi...

Страница 38: ... at http www ibm com de support ecurep terms html Step 1 You can use any of the following methods to send diagnostic data to Lenovo Standard upload http www ibm com de support ecurep send_http html Standard upload with the system serial number http www ecurep ibm com app upload_hw Secure upload http www ibm com de support ecurep send_http html secure Secure upload with the system serial number htt...

Страница 39: ...0 00 00000 00000 00000 00 00 00 00 00 00 Figure 11 Server components Blue on a component indicates touch points where you can grip the component to remove it from or install it in the server open or close a latch and so on Chapter 2 Installing optional devices 25 ...

Страница 40: ...itional procedures that you might have to perform before you remove or install the component Server internal LEDs connectors and jumpers The illustrations in this section show the connectors LEDs and jumpers on the internal boards The illustrations might differ slightly from your hardware System board internal connectors The following illustrations show the internal connectors on the system board ...

Страница 41: ... jumpers The following illustration shows the location and description of the switches and jumpers Figure 14 Location and description of switches and jumpers The following table describes the jumper on the system board Chapter 2 Installing optional devices 27 ...

Страница 42: ...d 2 to pins 2 and 3 before the server is turned on alters which flash ROM page is loaded Do not change the jumper pin position after the server is turned on This can cause an unpredictable problem Important 1 Before you change any switch settings or move any jumpers turn off the server then disconnect all power cords and external cables Review the information in Safety on page v Installation guide...

Страница 43: ... and controls on system board System board optional device connectors The following illustration shows the connectors on the system board for user installable optional devices Chapter 2 Installing optional devices 29 ...

Страница 44: ...the riser card assemblies The server comes with one PCI riser card assembly installed in PCI riser connector 1 The riser card assembly provides either one or two PCI slots depending on the server model The following illustrations shows the connectors on PCI riser card assembly 1 30 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 45: ...se the installation guidelines to install the IBM System x3530 M4 Type 7160 Attention Static electricity that is released to internal server components when the server is powered on might cause the system to halt which might result in the loss of data To avoid this potential problem always use an electrostatic discharge wrist strap or other grounding system when removing or installing a hot swap d...

Страница 46: ...ur feet Use a slow lifting force Never move suddenly or twist when you lift a heavy object To avoid straining the muscles in your back lift by standing or by pushing up with your leg muscles Make sure that you have an adequate number of properly grounded electrical outlets for the server monitor and other devices Back up all important data before you make changes to disk drives Have a small flat b...

Страница 47: ... pins or exposed circuitry Do not leave the device where others can handle and damage it While the device is still in its static protective package touch it to an unpainted metal surface on the outside of the server for at least 2 seconds This drains static electricity from the package and from your body Remove the device from its package and install it directly into the server without setting dow...

Страница 48: ...teps Step 1 Read the safety information that begins in Safety on page v and Installation guidelines on page 31 Step 2 Turn off the server see Turning off the server on page 22 and all attached peripheral devices Disconnect all power cords then disconnect all external cables from the server Step 3 Remove the top cover see Removing the server top cover on page 33 Step 4 Lift the air baffle from the ...

Страница 49: ...en The server supports only industry standard double data rate 3 DDR3 1066 MHz PC3 8500 1333 MHz PC3 10600 or 1600 MHz PC3 12800 single rank dual rank or quad rank in specified models registered or unbuffered synchronous dynamic random access memory SDRAM dual inline memory modules DIMMs with error correcting code ECC The specifications of a DDR3 DIMM are on a label on the DIMM in the following fo...

Страница 50: ...he server quad rank DIMMs must be installed first When one quad rank DIMM is installed it must be installed in DIMM slot 1 The DIMM options that are available for the server are 2 GB 4 GB 8 GB 16 GB and 32 GB when available The server system board supports a minimum of 2 GB and a maximum of 96 GB of system memory Note The amount of usable memory is reduced depending on the system configuration A c...

Страница 51: ...he spare rank is held in reserve and is not available as system memory The spare rank must have identical or larger memory capacity than all the other ranks sparing source ranks on the same channel After sparing the sparing source rank will be lost DIMMs must be installed in sets of three The DIMMs in each set must be the same size and type The following table lists the DIMM installation sequence ...

Страница 52: ...stalled in the server Table 8 DIMM population sequence memory mirroring mode Number of installed microprocessors DIMM connector population sequence 1 3 5 4 6 2 3 5 9 11 4 6 10 12 When you install or remove DIMMs the server configuration information changes When you restart the server the system displays a message that indicates that the memory configuration has changed The following illustration s...

Страница 53: ...the DIMM so that the DIMM keys align correctly with the connector Step 7 Insert the DIMM into the connector by aligning the edges of the DIMM with the slots at the ends of the DIMM connector see System board optional device connectors on page 29 for the locations of the DIMM connectors Step 8 Firmly press the DIMM straight down into the connector by applying pressure on both ends of the DIMM simul...

Страница 54: ...tall a drive save the EMC shield and filler panel from the bay in the event that you later remove the device Installing hot swap drives Use this information to install a hot swap hard disk drive To install a hot swap SAS or SATA drive complete the following steps Note If you install only one drive you must install it in drive bay 0 Step 1 Read the safety information that begins in Safety on page v...

Страница 55: ...erver is configured for RAID operation using a ServeRAID adapter you might have to reconfigure your disk arrays after you install drives See the ServeRAID adapter documentation for additional information about RAID operation and complete instructions for using the ServeRAID adapter Step 6 If you are installing additional hot swap drives do so now Step 7 Restart the server Confirm that it starts co...

Страница 56: ...uch the static protective package that contains the drive to any unpainted metal surface on the server then remove the drive from the package and place it on a static protective surface Step 4 Install the hard disk drive in the drive bay a Remove the filler panel from the empty drive bay b Align the drive assembly with the guide rails in the bay 000000000000000000 000000000000000000 00000000000000...

Страница 57: ...for additional information about RAID operation and complete instructions for using the ServeRAID adapter If you have other devices to install or remove do so now Otherwise go to Completing the installation on page 73 Installing an optional optical drive Use this information to install an optional optical drive To install an optional optical drive complete the following steps Step 1 Read the safet...

Страница 58: ...he side of the drive filler Figure 30 retention clip removal Note If you are installing a drive that contains a laser observe the following safety precaution Statement 3 CAUTION When laser products such as CD ROMs DVD drives fiber optic devices or transmitters are installed note the following 44 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 59: ...of the new drive Step 9 Align the drive in the drive bay and slide the drive into the optical drive bay until the drive clicks into place If you have other devices to install or remove do so now Otherwise go to Completing the installation on page 73 Installing a PCI riser card assembly Use this information to install a PCI riser card assembly To install a PCI riser card assembly complete the follo...

Страница 60: ...w lenovo com serverproven Locate the documentation that comes with the adapter and follow those instructions in addition to the instructions in this section Do not set the maximum digital video adapter resolution above 1280 x 1024 at 75 Hz for an LCD monitor This is the highest resolution that is supported for any add on video adapter that you install in the server Any high definition video out co...

Страница 61: ...update the code ServeRAID controllers ServeRAID H1110 SAS SATA Controller for System x ServeRAID M1115 SAS SATA Controller for System x ServeRAID M5120 SAS SATA Controller for IBM System x ServeRAID M5110 SAS SATA Controller for IBM System x ServeRAID controller upgrade options ServeRAID M5100 Series 512 MB Cache RAID 5 Upgrade for IBM System x ServeRAID M5100 Series 512 MB Flash RAID 5 Upgrade fo...

Страница 62: ...assembly Press the edge of the connector firmly into the PCI riser card assembly Make sure that the adapter snaps into the PCI riser card assembly securely 000000 000000 000000 000000 Figure 32 Adapter installation in PCI riser card assembly 1 Step 6 Installing a ServeRAID adapter in PCI riser card assembly 2 1 Pull the release pin to unlock the release latch 2 Rotate the retention latch to the op...

Страница 63: ...controller Figure 34 ServeRAID adapter installation You can purchase an optional ServeRAID SAS SATA controller You must install the optional ServeRAID adapter in PCI slot 3 on PCI riser card assembly 2 If the server does not already come with PCI riser card assembly 2 you must purchase the PCI riser card assembly option For configuration information see the ServeRAID documentation at http www ibm ...

Страница 64: ...rrectly with the connector on the PCI riser card assembly Step 8 Insert the ServeRAID adapter into the connector on the riser card until it is firmly seated Attention Incomplete insertion might cause damage to the server or the adapter Step 9 Rotate the retention latch to the closed position making sure the retention latch engages the ServeRAID adapter Then push in the release pin to lock the rete...

Страница 65: ...ional microprocessor use microprocessors that have the same QuickPath Interconnect QPI link speed integrated memory controller frequency core frequency power segment internal cache size and type Mixing microprocessors of different stepping levels within the same server model is supported When mixing microprocessors with different stepping levels within the same server model you do not have to inst...

Страница 66: ...e on page 34 Step 5 Locate microprocessor socket 2 on the system board Step 6 Remove the heat sink filler if one is present Step 7 Open the microprocessor socket release lever and retainer a Press down and out on the release lever on microprocessor socket 2 and lift up the microprocessor release lever until it stops in the fully open position b Lift the hinged microprocessor bracket frame into an ...

Страница 67: ...ssor by the edges only Contaminants on the microprocessor contacts such as oil from your skin can cause connection failures between the contacts and the socket Handle the microprocessor carefully Dropping the microprocessor during installation or removal can damage the contacts d Remove the cover from the bottom of the microprocessor installation tool Press both microprocessor cover release tabs o...

Страница 68: ...ose the microprocessor release lever to the closed position to secure the microprocessor in the socket Step 9 Install the heat sink that came with the microprocessor a Remove the plastic protective cover from the bottom of the heat sink Attention Do not touch the thermal grease on the bottom of the heat sink after you remove the plastic cover Touching the thermal grease will contaminate it See The...

Страница 69: ... install the two fans on Fan connector 4 and Fan connector 6 of the system board respectively see Replacing a fan on page 213 Step 11 Reinstall the air baffle see Replacing the air baffle on page 74 Step 12 Reconnect any cables that you have disconnected from the adapters or system board If you have other devices to install or remove do so now Otherwise go to Completing the installation on page 73...

Страница 70: ...ng pad to wipe the thermal grease from the microprocessor then dispose of the cleaning pad after all of the thermal grease is removed Microprocessor 0 02 mL of thermal grease Figure 42 Thermal grease distribution Step 5 Use the thermal grease syringe to place 9 uniformly spaced dots of 0 02 mL each on the top of the microprocessor The outermost dots must be within approximately 5 mm of the edge of...

Страница 71: ...h efficiency hot swap power supply Note You cannot mix 110 V ac and 220 V ac or 460 watt and 675 watt power supplies in the server it is not supported Power supply 1 is the default primary power supply If power supply 1 fails you must replace the power supply with the same wattage immediately The server supports a maximum of two hot swap power supplies These power supplies are designed for paralle...

Страница 72: ...ply from the package and place it on a static protective surface Step 3 If you are installing a hot swap power supply into an empty bay remove the power supply filler panel from the power supply bay Figure 44 Power supply installation Step 4 Grasp the handle on the rear of the power supply with the gold contact then slide the power supply forward into the power supply bay until it clicks Make sure...

Страница 73: ...n label on the server Power supplies in the server must be with the same power rating or wattage to ensure that the server will operate correctly Figure 45 Power information label Step 10 If you are adding a power supply to the server attach the redundant power information label that comes with this option on the server cover near the power supplies Figure 46 Redundant power information label Step...

Страница 74: ...power supplies It is the customer s responsibility to supply the necessary power cable To reduce the risk of electric shock or energy hazards Use a circuit breaker that is rated at 25 amps Use 2 5 mm2 12 AWG at 90 C copper wire Torque the wiring terminal screws to 0 50 0 60 newton meters 4 43 5 31 inch pounds For more information see Statement 34 If the power source requires ring terminals you mus...

Страница 75: ...the installation and configuration procedures Connect and disconnect cables as described in the following table when you install move or open covers on this product or attached devices To Connect To Disconnect 1 Turn OFF all power sources and equipment that is to be attached to this product 2 Attach signal cables to the product 3 Attach power cords to the product For ac systems use appliance inlet...

Страница 76: ...iring See the specifications in the product documentation for the required circuit breaker rating for branch circuit overcurrent protection Use copper wire conductors only See the specifications in the product documentation for the required wire size See the specifications in the product documentation for the required torque values for the wiring terminal screws Important Be sure to read the multi...

Страница 77: ...ground and 48V return terminals Figure 47 DC power supply rear view Step 5 If you are installing a hot swap power supply into an empty bay remove the power supply filler from the power supply bay Figure 48 Power supply installation Step 6 Grasp the handle on the rear of the power supply and slide the power supply forward into the power supply bay until it clicks Make sure that the power supply con...

Страница 78: ...power LEDs on the power supply are lit indicating that the power supply is operating correctly Step 11 If you are replacing a power supply with one of a different wattage in the server apply the new power information label provided over the existing power information label on the server Power supplies in the server must be with the same power rating or wattage to ensure that the server will operat...

Страница 79: ...nes on page 31 Step 2 Turn off the server see Turning off the server on page 22 and all attached peripheral devices Disconnect all power cords then disconnect all external cables from the server Step 3 Remove the top cover see Removing the server top cover on page 33 Step 4 Remove PCIe riser card assembly 1 see Removing a PCI riser card assembly on page 241 Step 5 Locate the embedded hypervisor US...

Страница 80: ...ocation of the embedded hypervisor USB flash device Step 6 Slide the lockbar toward the riser card assembly to the locked position until it is seated firmly 66 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 81: ... power module must be installed remotely to prevent it from overheating The battery or power module must be installed in the RAID battery tray on top of the power interposer card To install a RAID adapter battery or power module remotely in the server complete the following steps Step 1 Read the safety information that begins in Safety on page v and Installation guidelines on page 31 Step 2 Turn o...

Страница 82: ...r card connector alignment c Press the interposer card down onto the interposer card connector on the RAID adapter until it is firmly seated d From underneath the RAID adapter insert the screw that you took from the bag and tighten the screw to secure the interposer card to the RAID adapter Step 5 Connect one end of the remote battery cable to the interposer card Attention To avoid damage to the h...

Страница 83: ...y comes with a battery carrier ensure that battery carrier posts align with the rings on the battery mounting slot so that the battery carrier is secure in the slot Note The positioning of the remote battery depends on the type of remote battery that you install b Rotate the retention clip to the close position and press down on the retention clip until it snaps in place to hold the battery in pla...

Страница 84: ... guide channels making sure that any nearby wires or cables are not trapped or pinched 00000000000000000000000000 00000000000000000000000000 00000000000000000000000000 00000000000000000000000000 00000000000000000000000000 00000000000000000000000000 00000000000000000000000000 00000000000000000000000000 00000000000000000000000000 00000000000000000000000000 00000000000000000000000000 0000000000000000...

Страница 85: ...Figure 57 Power cable installation for redundant power model b The fixed power model Chapter 2 Installing optional devices 71 ...

Страница 86: ...t the other end of the signal cable to the Port 1 connector on the RAID adapter or the connector on the system board Be sure to route the signal cable through the cage hole next to the power distribution board 72 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 87: ...ep 2 If you removed a PCIe riser card assembly reinstall it see Replacing a PCI riser card assembly on page 74 Step 3 If you removed the server cover replace it see Replacing the server top cover on page 75 Step 4 Install the server in the rack cabinet see the Rack Installation Instructions that come with the server for instructions Step 5 Reconnect the cables and power cords see Connecting the ca...

Страница 88: ...00000000000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 0000 0000 0000 Figure 60 Air baffle installation Replacing a PCI riser card assembly Use this information to replace the PCI riser card assembly To replace a PCI riser card assembly complete the following steps Step 1 Read the safety information that begins in Safety on page v and Installation guidel...

Страница 89: ...e the following steps Step 1 Make sure that all cables adapters and other components are installed and seated correctly and that you have not left loose tools or parts inside the server Also make sure that all internal cables are correctly routed Step 2 Align the cover over the server toward the rear of the server until the cover edges slip into position over the chassis Important Before you slide...

Страница 90: ...chassis Step 4 Install the server into the rack enclosure and push the server into the rack until it clicks into place Connecting the cables The following illustrations show the locations of the input and output connectors of the server The following illustration shows the locations of the input and output connectors on the front of the server Figure 63 Front of server The following illustration s...

Страница 91: ... The Setup utility starts automatically so that you can save the new configuration settings Some optional devices have device drivers that you must install For information about installing device drivers see the documentation that comes with each device If the server has an optional RAID adapter and you have installed or removed a hard disk drive see the documentation that comes with the RAID adap...

Страница 92: ...78 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 93: ... the update might solve the problem Be sure to separately install any listed critical updates that have release dates that are later than the release date of the UpdateXpress System Pack or UpdateXpress image The firmware for the server is periodically updated and is available for download on the IBM wb site To check for the latest level of firmware such as the UEFI firmware vital product data VPD...

Страница 94: ...de the startup sequence that is set in the Setup utility and temporarily assign a device to be first in the startup sequence For more information about using this program see Using the Boot Manager program on page 89 IBM ServerGuide Setup and Installation CD The ServerGuide program provides software setup tools and installation tools that are designed for the server Use this CD during the installa...

Страница 95: ... the blue screen capture feature to assist in determining the cause of the hang condition Ethernet controller configuration For information about configuring the Ethernet controller see Configuring the Gigabit Ethernet controller on page 94 Configuring RAID arrays For information about configuring RAID arrays see Configuring RAID arrays on page 95 IBM Advanced Settings Utility ASU program Use this...

Страница 96: ...lable from the CD Detects installed hardware options and provides updated device drivers for most adapters and devices Provides diskette free installation for supported Windows operating systems Includes an online readme file with links to tips for your hardware and operating system installation Setup and configuration overview Use this information for the ServerGuide setup and configuration When ...

Страница 97: ...up utility Use the Unified Extensible Firmware Interface UEFI Setup Utility program to perform the following tasks View configuration information View and change assignments for devices and I O ports Set the date and time Set and change passwords Set the startup characteristics of the server and the order of startup devices Set and change settings for advanced hardware features View set and change...

Страница 98: ...d device drivers installed in the server that are compliant with UEFI 1 10 and UEFI 2 0 Processors Select this choice to view or change the processor settings Memory Select this choice to view or change the memory settings To configure memory mirroring select System Settings Memory Memory Mode Mirrored Devices and I O Ports Select this choice to view or change assignments for devices and input out...

Страница 99: ... balance between performance and power Minimal power mode maximizes power savings Memory Power Management Select this choice to enable or disable power management on memory If you choose Disabled it will provide maximum performance but minimum power savings If you choose Automatic it is suitable for most applications Proc Performance States Select this choice to enable or disable processor perform...

Страница 100: ...Cs are supported for legacy PXE boot If more than four NICs are installed legacy PXE boot will not be attempted on some of the NICs To enable legacy PXE boot on the desired NIC connectors prioritize the desired NIC connectors by changing the Rom execution Order or disable the NIC connectors that you do not use from Enable Disable Adapter Option ROM Support menu Force Legacy Video on Boot Select th...

Страница 101: ...p sequence keyboard NumLock state PXE boot option and PCI device boot priority Changes in the startup options take effect when you start the server The startup sequence specifies the order in which the server checks devices to find a boot record The server starts from the first boot record that it finds If the server has Wake on LAN hardware and software and the operating system supports Wake on L...

Страница 102: ...hoice to save the changes that you have made in the settings Restore Settings Select this choice to cancel the changes that you have made in the settings and restore the previous settings Load Default Settings Select this choice to cancel the changes that you have made in the settings and restore the factory settings Exit Setup Select this choice to exit from the Setup utility If you have not save...

Страница 103: ... any switch settings or move any jumpers turn off the server then disconnect all power cords and external cables See the safety information that begins in Safety on page v Do not change settings or move jumpers on any system board switch or jumper blocks that are not shown in this document Clearing CMOS data does not affect the administrator password Administrator password If an administrator pass...

Страница 104: ...e presence function in a single chip The IMM supports the following basic systems management features Active Energy Manager Alerts in band and out of band alerting PET traps IPMI style SNMP e mail Auto Boot Failure Recovery ABR Automatic microprocessor disable on failure and restart in a two microprocessor configuration when one microprocessor signals an internal error When one of the microprocess...

Страница 105: ...s through the IPMI 2 0 protocol Use the command line interface to issue commands to control the server power view system information and identify the server You can also save one or more commands as a text file and run the file as a script Serial over LAN Establish a Serial over LAN SOL connection to manage servers from a remote location You can remotely view and change the UEFI settings restart t...

Страница 106: ...elect Boot Manager Step 4 Select Add Boot Option then select USB Storage Press Enter and then select Esc Step 5 Select Change Boot Order and then select Commit Changes then press Enter Step 6 Select Save Settings and then select Exit Setup If the embedded hypervisor flash device image becomes corrupt you can use the VMware Recovery CD that comes with the system to recover the flash device image To...

Страница 107: ...eature Obtaining the IP address for the IMM Use this information to obtain the IP address for the IMM If you are logging on to the IMM for the first time after installation the IMM defaults to DHCP If a DHCP server is not available the IMM uses a static IP address of 192 168 70 125 The default IPv4 host name is IMM plus the last 12 characters on the IMM MAC address The default host name also comes...

Страница 108: ...ppears in the startup sequence Enable and disable the Intel Gigabit Ethernet Utility program from the Setup utility Configuring the Gigabit Ethernet controller Use this information to configure the Gigabit Ethernet controller The Ethernet controllers are integrated on the system board They provide an interface for connecting to a 10 Mbps 100 Mbps or 1 Gbps network and provide full duplex FDX capab...

Страница 109: ...de for ServeRAID M controllers see http www 947 ibm com support entry portal docdisplay lndocid MIGR 5085607 2 For more information about Configuration and Options Guide COG see http www 947 ibm com support entry portal docdisplay lndocid SCOD 3ZVQ5W brandind 5000019 3 For further details on creating a software RAID array of hard disk drives please see the ServeRAID C105 documentation at http www ...

Страница 110: ...control button becomes active after the power on LED flashes slowly 2 When prompted F1 Setup is displayed press F1 If you have set an administrator password you are prompted to type the password 3 Under System Settings select Storage When you have finished changing settings press Esc to exit from the program select Save to save the settings that you have changed Creating RAID of hard disk drives S...

Страница 111: ...tomating the activation and installation of the activation key by using IBM ToolsCenter or IBM Systems Director see the IBM Features on Demand User s Guide at http www ibm com systems x fod under the Help section 3 Software RAID does not support VMware 5 and VMware 4 1 4 Software RAID does not support legacy configuration 5 In order to install the legacy OS in the software RAID you have to set the...

Страница 112: ...the Systems Director If you plan to use the Systems Director to manage the server you must check for the latest applicable Systems Director updates and interim fixes Note Changes are made periodically to the Web site The actual procedure might vary slightly from what is described in this document To locate and install a newer version of Systems Director complete the following steps Step 1 Check fo...

Страница 113: ...n this document 1 Download the Advanced Settings Utility ASU a Go to http www lenovo com support b Click on the Downloads tab at the top of the panel c Under ToolsCenter select View ToolsCenter downloads d Select Advanced Settings Utility ASU e Scroll down and click on the link and download the ASU version for your operating system 2 ASU sets the UUID in the Integrated Management Module IMM Select...

Страница 114: ... and password default values asu set SYSTEM_PROD_DATA SYsInfoUUID uuid_value user user_id password password Example that does use the userid and password default values asu set SYSTEM_PROD_DATA SysInfoUUID uuid_value Online KCS access unauthenticated and user restricted You do not need to specify a value for access_method when you use this access method Example asu set SYSTEM_PROD_DATA SysInfoUUID...

Страница 115: ... scroll down for the available tools 5 Restart the server Updating the DMI SMBIOS data Use this information to update the DMI SMBIOS data The Desktop Management Interface DMI must be updated when the system board is replaced Use the Advanced Settings Utility ASU to update the DMI in the UEFI based server The ASU is an online tool that supports several operating systems Make sure that you download ...

Страница 116: ... type and model number Type mtm xxxxyyy where xxxx is the machine type and yyy is the server model number s n The serial number on the server Type sn zzzzzzz where zzzzzzz is the serial number asset_method The server asset tag number Type asset aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa where aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa is the asset tag number access_method The access method that you select to use fr...

Страница 117: ... link and download the ASU version for your operating system Scroll down and look under Online Help to download the Advanced Settings Utility Users Guide The following commands are examples of using the userid and password default values and not using the default values Examples that do not use the userid and password default values asu set SYSTEM_PROD_DATA SYsInfoProdName m t_model asu set SYSTEM...

Страница 118: ...SerialNum s n host imm_ip asu set SYSTEM_PROD_DATA SysEncloseAssetTag asset_tag host imm_ip Bootable media You can also build a bootable media using the applications available through the ToolsCenter Web site at https support lenovo com us en documents LNVO CENTER From the IBM ToolsCenter page scroll down for the available tools 5 Restart the server 104 Lenovo System x3530 M4 Installation and Serv...

Страница 119: ...d If any hardware software or firmware was changed before the problem occurred if possible reverse those changes This might include any of the following items Hardware components Device drivers and firmware System software UEFI firmware System input power or network connections Step 2 View the light path diagnostics LEDs and event logs The server is designed for ease of diagnosis of hardware and s...

Страница 120: ... running preboot diagnostics For more information about UpdateXpress System Packs see http www ibm com support entry portal docdisplay lndocid SERV XPRESSand Updating the firmware on page 79 For more information about the Bootable Media Creator see https support lenovo com us en documents LNVO BOMC Be sure to separately install any listed critical updates that have release dates that are later tha...

Страница 121: ...tips go to http www lenovo com support Step 8 Use the troubleshooting tables See Troubleshooting by symptom on page 126 to find a solution to a problem that has identifiable symptoms A single problem might cause multiple symptoms Follow the troubleshooting procedure for the most obvious symptom If that procedure does not diagnose the problem use the procedure for another symptom if possible If the...

Страница 122: ... is part of a shared hard disk drive cluster two or more servers sharing external storage devices If it is part of a cluster you can run all diagnostic programs except the ones that test the storage unit that is a hard disk drive in the storage unit or the storage adapter that is attached to the storage unit The failing server might be part of a cluster if any of the following conditions is true Y...

Страница 123: ...e server is running to ensure proper cooling i Check for the following results Successful completion of POST see POST on page 123 for more information Successful completion of startup which is indicated by a readable display of the operating system desktop Step 3 Is there a readable image on the monitor screen No Find the failure symptom in Troubleshooting by symptom on page 126 if necessary see S...

Страница 124: ...sing server problems DSA Portable runs on the server s operating system and collect the following information about the server Drive health information Event logs for ServeRAID controllers and service processors Installed hardware including PCI and USB information Installed applications and hot fixes Kernel modules Light path diagnostics status Microprocessor input out hub and UEFI error logs Netw...

Страница 125: ...ng by symptom on page 126 for more information Light path diagnostics Light path diagnostics is a system of LEDs on various external and internal components of the server that leads you to the failed component When an error occurs LEDs are lit along the path of the front panel the light path diagnostics panel then on the failed component By viewing the LEDs in a particular order you can often iden...

Страница 126: ...tor information panel press the blue latch on the right of the operator panel Lit LEDs on this panel indicate the type of error that has occurred Look at the system service label inside the server cover which gives an overview of internal components that correspond to the LEDs on the light path diagnostics panel This information and the information in Light path diagnostics LEDs on page 115 can of...

Страница 127: ...agnostics panel The light path diagnostics panel is available on the top of the advanced operator information panel For additional information about the light path diagnostics and LEDs on the light path diagnostics panel see Light path diagnostics on page 111 and Light path diagnostics LEDs on page 115 Chapter 4 Troubleshooting 113 ...

Страница 128: ... the server to check the LEDs do not run the server continuously with light path diagnostics panel outside of the server The panel should only be outside of the server a short time The optional advanced light path diagnostics panel must remain in the server when the server is running to ensure proper cooling The following illustration shows the LEDs and controls on the light path diagnostics panel...

Страница 129: ...bout the error 2 Save the log if necessary and clear the log afterwards System Error LED An error occurred 1 Check the light path LEDs and follow the listed instruction 2 Check the IMM2 system even log and the system error log for information about the error 3 Save the log if necessary and clear the log afterwards OVER SPEC The power supplies are using more power than their maximum rating The syst...

Страница 130: ...sure that the air vents are not blocked 2 Determine whether a fan has failed If it has replace it 3 Make sure that the heat sink is seated correctly 4 Make sure that the room temperature is not too high See Server features and specifications on page 5 and System reliability guidelines on page 32 for the server temperature information MEM An invalid memory configuration both the MEM LED and CONFIG ...

Страница 131: ...ted see Installing a memory module on page 35 for DIMM requirements and installation sequence information b Replace the DIMMs with a supported configuration An invalid microprocessor configuration or a microprocessor has failed both the CPU LED and the CONFIG LED might be lit 1 If the CONFIG LED is lit the system issues an invalid microprocessor configuration error Complete the following steps to ...

Страница 132: ...hard disk drives for the drive with a lit status LED and reseat the hard disk drive 2 Make sure that the cables are correctly connected to the hard disk drive backplane 3 For more information see Hard disk drive problems on page 128 4 If the error remains replace the following components in the order listed restarting the server after each a Replace the hard disk drive b Replace the hard disk driv...

Страница 133: ...stem board One power supply Power cord Four cooling fans The following illustrations show the locations of the power supply LEDs for fixed and redundant models respectively Figure 71 Power supply LEDs locations 000 000 000 000 00000000000 00000000000 00000000000 00000000000 000000 000000000 000 000 000 0000000000 0000000000 0000000000 0000000000 000000 000000000 000 000 000 The following table des...

Страница 134: ...faulty Replace the power supply Event logs Error codes and messages are displayed in POST event log system event log integrated management module IMM2 event log and DSA event log POST event log This log contains the three most recent error codes and messages that were generated during POST You can view the contents of the POST event log from the Setup utility see Starting the Setup utility on page...

Страница 135: ...age 121 and Clearing the error logs on page 122 Viewing event logs through the Setup utility Use this information to view the event logs through the Setup utility To view the POST event log or system event log complete the following steps Step 1 Turn on the server Step 2 When the prompt F1 Setup is displayed press F1 If you have set both a power on password and an administrator password you must t...

Страница 136: ...iew the system event log requires IPMI driver Use the Web browser interface to the IMM to view the system event log locally requires RNDIS USB LAN driver For more information see Obtaining the IP address for the IMM on page 93 and Logging on to the Web interface on page 94 The integrated management module IMM is connected to a network and AC power is applied the server state might be hung not hung...

Страница 137: ...mation If POST detects a problem an error message is sent to the POST event log see Event logs on page 120 for more information Dynamic System Analysis Dynamic System Analysis DSA collects and analyzes system information to aid in diagnosing server problems DSA collects the following information about the server Drive health information Event logs for ServeRAID controllers and service processors H...

Страница 138: ...uch as a CD DVD ISO USB or PXE using the IBM ToolsCenter Bootable Media Creator BoMC For more details see the BoMC User Guide at https support lenovo com us en documents LNVO BOMC In addition to the capabilities of the other editions of DSA DSA Preboot includes diagnostic routines that would be disruptive to run within the operating system environment such as resetting devices and causing loss of ...

Страница 139: ...e the component that was being tested when the server stopped Diagnostic text messages Diagnostic text messages are displayed while the tests are running A diagnostic text message contains one of the following results Passed The test was completed without any errors Failed The test detected an error Aborted The test could not proceed because of the server configuration Additional information conce...

Страница 140: ...FI POST IMM2 and DSA that are generated when a problem is detected See Appendix B UEFI POST error codes on page 639 Appendix A Integrated Management Module II IMM2 error messages on page 279 and Appendix C DSA diagnostic test results on page 663 for more information Troubleshooting by symptom Use the troubleshooting tables to find solutions to problems that have identifiable symptoms Use the troub...

Страница 141: ...s on page 663 4 Reseat the CD or DVD drive see Removing a CD DVD drive on page 206 and Installing an optional CD DVD drive on page 207 5 Replace the CD or DVD drive The CD or DVD drive tray is not working 1 Make sure that the server is turned on 2 Insert the end of a straightened paper clip into the manual tray release opening 3 Reseat the CD or DVD drive see Removing a CD DVD drive on page 206 an...

Страница 142: ...ile running and the server shut off Replace the server cover and restart the server The server is hung while the screen is on Cannot start the Setup utility by pressing F1 1 See Nx boot failure on page 146 for more information 2 See Recovering the server firmware UEFI update failure on page 144 for more information Hard disk drive problems Follow the suggested actions in the order in which they ar...

Страница 143: ...If the green activity LED is flashing and the yellow status LED is lit replace the drive If the activity of the LEDs remains the same go to step Hard disk drive problems on page 128 If the activity of the LEDs changes return to step 1 4 Make sure that the hard disk drive backplane is correctly seated When it is correctly seated the drive assemblies correctly connect to the backplane without bowing...

Страница 144: ... associated drive 1 If the yellow hard disk drive LED and the RAID adapter software do not indicate the same status for the drive complete the following steps a Turn off the server b Reseat the SAS SATA adapter c Reseat the backplane signal cable and backplane power cable d Reseat the hard disk drive e Turn on the server and observe the activity of the hard disk drive LEDs 2 See Problem determinat...

Страница 145: ...by Trained technician only that step must be performed only by a trained technician Symptom Action All or some keys on the keyboard do not work 1 Make sure that The keyboard cable is securely connected The server and the monitor are turned on 2 If you are using a USB keyboard run the Setup utility and enable keyboardless operation 3 See http www lenovo com serverproven for information about keyboa...

Страница 146: ...Note If you change memory you must update the memory configuration in the Setup utility 1 Make sure that No error LEDs are lit on the operator information panel on the memory tray or on the MAX5 memory expansion module Memory mirroring does not account for the discrepancy The memory modules are seated correctly see Removing a memory module on page 214 and Replacing a memory module on page 215 You ...

Страница 147: ...blems Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved See Chapter 5 Parts listing IBM System x3530 M4 Type 7160 on page 147 to check if a component is a consumable structural or FRU part If an action step is preceded by Trained technician only that step must be performed only by a trained technician Symptom Action The server goes ...

Страница 148: ...The monitor cables are connected correctly The monitor is turned on and the brightness and contrast controls are adjusted correctly 3 Make sure that the correct server is controlling the monitor if applicable 4 Make sure that damaged server firmware is not affecting the video see Updating the firmware on page 79 5 Observe the checkpoint LEDs on the system board if the codes are changing go to step...

Страница 149: ... a To prevent diskette drive read write errors make sure that the distance between the monitor and any external diskette drive is at least 76 mm 3 in b Non IBM monitor cables might cause unpredictable problems 2 Reseat the monitor cable 3 Replace the components listed in step 2 one at a time in the order shown restarting the server each time a Monitor cable b Video adapter if one is installed c Mo...

Страница 150: ...ED flashes slowly 2 When prompted F1 Setup is displayed press F1 If you have set an administrator password you are prompted to type the password 3 Under System Configuration and Boot Management select System Settings 4 Under System Settings select Network 5 Under Network select the port number 6 Under the chosen port number select Intel R I350 Gigabit Network Connection 7 Under Main Configuration ...

Страница 151: ...he failing device 5 Replace the failing device Power problems Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved See Chapter 5 Parts listing IBM System x3530 M4 Type 7160 on page 147 to check if a component is a consumable structural or FRU part If an action step is preceded by Trained technician only that step must be performed only...

Страница 152: ...u might have installed more devices than the power supply supports 9 See Power supply LEDs on page 119 10 See Solving undetermined problems on page 142 The server does not start 1 Check the power LED on the system board See System board LEDs on page 28 for the LED location 2 Reseat the power supply 3 Replace the power supply The server does not start Continued The server does not turn off 1 Determ...

Страница 153: ...ce the system board ServerGuide problems Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved See Chapter 5 Parts listing IBM System x3530 M4 Type 7160 on page 147 to check if a component is a consumable structural or FRU part If an action step is preceded by Trained technician only that step must be performed only by a trained technic...

Страница 154: ...he problem is solved See Chapter 5 Parts listing IBM System x3530 M4 Type 7160 on page 147 to check if a component is a consumable structural or FRU part If an action step is preceded by Trained technician only that step must be performed only by a trained technician Symptom Action You suspect a software problem 1 To determine whether the problem is caused by the software make sure that The server...

Страница 155: ...ect all ac power cords Step 2 Check for loose cables in the power subsystem Also check for short circuits for example if a loose screw is causing a short circuit on a circuit board Step 3 If the system error LED on the system board is lit complete the following steps a Check the IMM2 event log To access the web interface see Logging on to the Web interface on page 94 b If a log indicates that ther...

Страница 156: ...f the Ethernet transmit receive activity is off make sure that the hub and network are operating and that the correct device drivers are installed Check for operating system specific causes of the problem Make sure that the device drivers on the client and server are using the same protocol If the Ethernet controller still cannot connect to the network but the hardware appears to be working the ne...

Страница 157: ...n problem determination If possible have this information available when requesting assistance from IBM The model number and serial number are located on the ID label on the front of the server as shown in the following illustration Note The illustrations in this document might differ slightly from your hardware Figure 72 ID label Machine type and model Microprocessor or hard disk drive upgrades F...

Страница 158: ...u can recover the server firmware in either of two ways In band method Recover server firmware using either the boot block jumper Automated Boot Recovery and a server Firmware Update Package Service Pack Out of band method Use the IMM Web interface to update the firmware using the latest server firmware update package Notes You can obtain a server update package from one of the following sources D...

Страница 159: ... line type filename s where filename is the name of the executable file that you downloaded with the firmware update package Step 11 Turn off the server and disconnect all power cords and external cables and then remove the server cover Step 12 Move the UEFI boot recovery jumper back to the primary position pins 1 and 2 Step 13 Reinstall the server cover and then reconnect all the power cables Ste...

Страница 160: ... failure Use this information for Nx boot failure Configuration changes such as added devices or adapter firmware updates and firmware or application code problems can cause the server to fail POST the power on self test If this occurs the server responds in either of the following ways The server restarts automatically and attempts POST again The server hangs and you must manually restart the ser...

Страница 161: ...ent of structural parts components such as chassis assembly top cover and bezel is your responsibility If Lenovo acquires or installs a structural component at your request you will be charged for the service Tier 1 customer replaceable unit CRU Replacement of Tier 1 CRUs is your responsibility If Lenovo installs a Tier 1 CRU at your request you will be charged for the installation Tier 2 customer...

Страница 162: ...00 000000 000000 000000 000000 00 00 00 00000 00000 00000 00 00 00 00 00 00 Figure 74 Server components The following table lists the part numbers for the server components 148 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 163: ... supply 675 Watt 69Y5943 9 Heat sink assembly all models 94Y7813 10 Microprocessor Intel Xeon E5 2403 v2 1 8 GHz 10 MB 80 W quad core 46W4281 10 Microprocessor Intel Xeon E5 2407 v2 2 4 GHz 10 MB 80 W quad core 46W4282 10 Microprocessor Intel Xeon E5 2420 v2 2 2 GHz 15 MB 80 W six core 46W4283 10 Microprocessor Intel Xeon E5 2430 v2 2 5 GHz 15 MB 80 W six core 46W4284 10 Microprocessor Intel Xeon ...

Страница 164: ...20 MB 8 0GT S QPI 70 W eight core 00D8761 10 Microprocessor Intel Xeon E5 2418L 2 0 GHz 10 MB 50 W quad core 00D8762 10 Microprocessor Intel Xeon E5 1410 2 8 GHz 10 MB 80 W quad core 00D9038 10 Microprocessor Intel Xeon E5 2418L v2 2 0 GHz 15 MB 45 W six core 00Y8135 10 Microprocessor Intel Xeon E5 2428L v2 2 4 GHz 20 MB 60 W eight core 00Y8136 10 Microprocessor Intel Xeon E5 2448L v2 2 0 GHz 25 M...

Страница 165: ...ard disk drive 3 5 inch 512e Near Line SAS hot swap 2 TB 7 2K 12 Gbps 00FN189 25 Hard disk drive 3 5 inch 512e Near Line SAS hot swap 4 TB 7 2K 12 Gbps 00FN209 25 Hard disk drive 3 5 inch 512e Near Line SAS hot swap 6 TB 7 2K 12 Gbps 00FN229 25 Self encrypting disk drive 3 5 inch 512e Near Line SAS hot swap 2 TB 7 2K 12 Gbps 00FN239 25 Self encrypting disk drive 3 5 inch 512e Near Line SAS hot swa...

Страница 166: ...lti level cell hot swap 960 GB SATA 00FN333 27 Hard disk drive 2 5 inch hot swap 900 GB 10 K 81Y9651 27 Hard disk drive 2 5 inch hot swap 1 TB 7 2 K 81Y9691 27 Hard disk drive 2 5 inch hot swap 250 GB 7 2 K 81Y9723 27 Hard disk drive 2 5 inch hot swap 500 GB 7 2 K 81Y9727 27 Hard disk drive 2 5 inch hot swap 1 TB 7 2 K 81Y9731 27 Hard disk drive 2 5 inch hot swap 300 GB 15 K 81Y9671 27 Hard disk d...

Страница 167: ...1 35 V DDR3 1333MHz RDIMM 49Y1415 35 Memory 8 GB quad rank 1 35 V DDR3 1333MHz RDIMM 49Y1417 35 Memory 4 GB dual rank 1 35 V DDR3 1333MHz UDIMM 49Y1422 35 Memory 2 GB single rank 1 35 V DDR3 1333MHz RDIMM 49Y1423 35 Memory 4 GB single rank 1 35 V DDR3 1333MHz RDIMM 49Y1424 35 Memory 4 GB dual rank 1 35 V DDR3 1333MHz RDIMM 49Y1425 35 Memory 4 GB single rank 1 5 V DDR3 1600MHz RDIMM 49Y1561 35 Memo...

Страница 168: ...8 6Gbps external mini SAS 00YE306 Cable 6 M SFF 8088 to SFF 8088 6Gbps external mini SAS 00YE302 Cable 6 M SFF 8644 to SFF 8088 6Gbps external mini SAS 00YE307 Cable 1 5 M KVM conversion 39M2911 Cable 3 5 inch hot swap power 81Y7308 Cable 2 5 inch simple swap power 81Y7312 Cable 2 5 inch power 81Y7316 Cable 3 5 inch signal 81Y7306 Cable 2 5 inch signal 81Y7314 Cable serial conversion 46M4027 Cable...

Страница 169: ...adapter 00JY847 Emulex 8Gb FC single port host bus adapter 42D0491 Emulex 8Gb FC dual port host bus adapter 00JY848 Emulex 8Gb FC dual port host bus adapter 42D0500 Video adapter NVIDIA Quadro 600 43V5931 4Gb FC PCIe single port adapter 43W7510 4Gb FC PCIe dual port adapter 43W7512 ServeRAID M1115 SAS SATA adapter 46C8928 ServeRAID M5100 series 512 MB flash RAID 5 upgrade 46C9027 ServeRAID M5100 s...

Страница 170: ...40 T4 Ethernet quad port adapter 94Y5167 Broadcom NetXtreme II dual port 10Gb adapter 49Y7912 Endeavor basic 10Gb BE3 R adapter 00D8543 NetXtreme II 1000 express Ethernet dual port adapter 49Y7947 NetXtreme II 1000 express Ethernet quad port adapter 49Y7949 Intel X520 DA2 dual port 10Gb virtual fabric adapter 49Y7962 Brocade 4Gb FC single port host bus adapter 59Y1992 Brocade 4Gb FC dual port host...

Страница 171: ...ber that is listed on the retail parts page or contact your local Lenovo representative for assistance Structural parts Structural parts are not covered by the Lenovo Statement of Limited Warranty You can place an order on the structural parts from the Lenovo retail store Table 16 Structural parts Type 7160 Index Description Part number 1 Top cover 00D4437 2 Power supply unit cage redundant 00D444...

Страница 172: ...d Canada are listed by Underwriter s Laboratories UL and certified by the Canadian Standards Association CSA For units intended to be operated at 115 volts Use a UL listed and CSA certified cord set consisting of a minimum 18 AWG Type SVT or SJT three conductor cord a maximum of 15 feet in length and a parallel blade grounding type attachment plug rated 15 amperes 125 volts For units intended to b...

Страница 173: ...frica Sri Lanka Swaziland Uganda 39M5151 Abu Dhabi Bahrain Botswana Brunei Darussalam Channel Islands China Hong Kong S A R Cyprus Dominica Gambia Ghana Grenada Iraq Ireland Jordan Kenya Kuwait Liberia Malawi Malaysia Malta Myanmar Burma Nigeria Oman Polynesia Qatar Saint Kitts and Nevis Saint Lucia Saint Vincent and the Grenadines Seychelles Sierra Leone Singapore Sudan Tanzania United Republic o...

Страница 174: ...160 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 175: ...r shipping that are supplied to you Internal cable routing This section provides information about routing the cables when you install some components in the server For more information about the requirements for cables and connecting devices see the documentation that comes with these devices Attention Failing to install or remove the cable with care may damage the connectors on the system board ...

Страница 176: ...162 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 177: ...e from the system board properly may damage the connector on the system board Any damage to the connector may require replacing the system board The following illustrations show the cabling information for the power interposer card assembly for fixed and redundant power supply models respectively Chapter 6 Removing and replacing structural parts 163 ...

Страница 178: ...wer interposer card assembly for fixed and redundant power supply models The following illustration shows the cabling information for installing the RAID battery remotely in the server 164 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 179: ...tion shows the 2 5 inch hard disk drive cable connection 4 drive capable model The following illustrations show the cabling information for the model of 4x2 5 inch hot swap drive bays The following illustration shows the cabling information for the configuration cable in the server Chapter 6 Removing and replacing structural parts 165 ...

Страница 180: ...gure 78 Cabling information for the configuration cable The following illustration shows the cabling information for the power cable in the server 166 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 181: ...Figure 79 Cabling information for the power cable redundant power model Chapter 6 Removing and replacing structural parts 167 ...

Страница 182: ...abling information for the power cable fixed power model The following illustration shows the cabling information for the hardware RAID cable in the server 168 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 183: ...re 81 Cabling information for the hardware RAID cable The following illustration shows the cabling information for the software RAID cable in the server Chapter 6 Removing and replacing structural parts 169 ...

Страница 184: ... cabling information for the model of 8x2 5 inch drive bays The following illustrations show the cabling information for the two 4x2 5 inch hot swap drives model The following illustration shows the cabling information for the configuration cable in the server 170 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 185: ...Figure 83 Cabling information for the configuration cable The following illustrations show the cabling information for the power cable in the server Chapter 6 Removing and replacing structural parts 171 ...

Страница 186: ...Figure 84 Cabling information for the power cable redundant power model 172 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 187: ... Cabling information for the power cable fixed power model The following illustration shows the cabling information for the hardware RAID cable in the server Chapter 6 Removing and replacing structural parts 173 ...

Страница 188: ... 86 Cabling information for the hardware RAID cable The following illustration shows the cabling information for the software RAID cable in the server 174 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 189: ...able The following illustrations show the cabling information for the two 4x2 5 inch simple swap drives model The following illustrations show the cabling information for the power cable in the server Chapter 6 Removing and replacing structural parts 175 ...

Страница 190: ...Figure 88 Cabling information for the power cable redundant power model 176 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 191: ... Cabling information for the power cable fixed power model The following illustration shows the cabling information for the hardware RAID cable in the server Chapter 6 Removing and replacing structural parts 177 ...

Страница 192: ... 90 Cabling information for the hardware RAID cable The following illustration shows the cabling information for the software RAID cable in the server 178 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 193: ... 3 5 inch hard disk drive cable connection 3 5 inch hot swap model The following illustrations show the cabling information for the 4x3 5 inch hot swap SATA SAS drive backplane assembly The following illustration shows the cabling information for the configuration cable in the server Chapter 6 Removing and replacing structural parts 179 ...

Страница 194: ...gure 92 Cabling information for the configuration cable The following illustrations show the cabling information for the power cable in the server 180 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 195: ...Figure 93 Cabling information for the power cable redundant power model Chapter 6 Removing and replacing structural parts 181 ...

Страница 196: ...abling information for the power cable fixed power model The following illustration shows the cabling information for the hardware RAID cable in the server 182 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 197: ...re 95 Cabling information for the hardware RAID cable The following illustration shows the cabling information for the software RAID cable in the server Chapter 6 Removing and replacing structural parts 183 ...

Страница 198: ...wap model The following illustration shows the cabling information for the 4x3 5 inch simple swap SATA drive backplate assembly The following illustrations show the cabling information for the power cable in the server 184 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 199: ...Figure 97 Cabling information for the power cable redundant power model Chapter 6 Removing and replacing structural parts 185 ...

Страница 200: ...abling information for the power cable fixed power model The following illustration shows the cabling information for the hardware RAID cable in the server 186 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 201: ...re 99 Cabling information for the hardware RAID cable The following illustration shows the cabling information for the software RAID cable in the server Chapter 6 Removing and replacing structural parts 187 ...

Страница 202: ...the server top cover Attention If you release the cover latch and remove the cover while the server is running the server will lose power and turn off automatically After you reinstall the cover you can power on the server again To remove the server top cover complete the following steps Step 1 Read the safety information that begins in Safety on page v and Installation guidelines on page 31 Step ...

Страница 203: ... If you are instructed to return the cover follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing the server top cover Use this information to replace the cover To replace the server cover complete the following steps Step 1 Make sure that all cables adapters and other components are installed and seated correctly and that you have not lef...

Страница 204: ...ep 1 Read the safety information that begins in Safety on page v and Installation guidelines on page 31 Step 2 Turn off the server see Turning off the server on page 22 and all attached peripheral devices Disconnect all power cords then disconnect all external cables as necessary to replace the device Step 3 If the server has been installed in a rack press the two release latches on the front of t...

Страница 205: ...hat are supplied to you Replacing the bezel Use this information to install the bezel To install the bezel complete the following steps Step 1 Insert the tabs on the bottom of the bezel into the holes on the chassis Step 2 Rotate the bezel upward to the server and reinstall the bezel screws Then install the EIA quick latch 000000000000000000 000000000000000000 000000000000000000 000000000000000000...

Страница 206: ...from the server and set it aside Attention For proper cooling and airflow replace the air baffle before you turn on the server Operating the server with the air baffle removed might damage server components 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 0000...

Страница 207: ... The illustrations in this document might differ slightly from your hardware Removing an adapter Use this information to remove an adapter To remove an adapter complete the following steps Step 1 Read the safety information that begins in Safety on page v and Installation guidelines on page 31 Step 2 Turn off the server see Turning off the server on page 22 and all attached peripheral devices Disc...

Страница 208: ...e or upper corners and pull the adapter from the PCI riser card assembly 00000000 00000000 00000000 00000000 Figure 108 Adapter removal from PCI riser card assembly 2 Step 8 Place the adapter on a flat static protective surface Step 9 If you are instructed to return the adapter follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing an adap...

Страница 209: ... the adapter See the documentation for your adapter for information and instructions Step 1 Read the safety information that begins in Safety on page v and Installation guidelines on page 31 Step 2 Follow the cabling instructions if any come with the adapter Route the adapter cables before you install the adapter Step 3 Installing an adapter in PCI riser card assembly 1 Insert the adapter into the...

Страница 210: ...the peripheral devices and the server Step 11 If you are replacing a ServeRAID adapter import your RAID configuration to the replacement adapter as a foreign configuration See the ServeRAID M Software User Guide at https www 947 ibm com support entry portal docdisplay lndocid migr 5086126 for instructions Removing hot swap drives Use this information to remove a hot swap hard disk drive Attention ...

Страница 211: ...ted to return the drive assembly follow all packaging instructions and use any packaging materials for shipping that are supplied to you Installing hot swap drives Use this information to install a hot swap hard disk drive Note If you install only one drive you must install it in drive bay 0 To install a hot swap SAS or SATA drive complete the following steps Step 1 Read the safety information tha...

Страница 212: ...om the empty drive bay b Make sure that the drive tray handle is in the open unlocked position c Align the drive assembly with the guide rails in the bay d Gently push the drive assembly into the drive bay until the drive stops e Rotate the drive tray handle to the closed locked position Step 5 Check the drive status LED to verify that the drive is operating correctly If the yellow drive status LE...

Страница 213: ...SATA drive backplane configurations The following are illustrations of the hot swap drive backplanes that are supported on the server 4x2 5 inch drive backplane rear view SAS signal connector SAS power connector Cofiguration connector 8x2 5 inch drive backplane rear view SAS signal connector Cofiguration connector SAS signal connector SAS power connector 8x1 8 inch drive backplane rear view Chapte...

Страница 214: ...ive bay IDs can vary depending on the combination of the SAS SATA drive backplanes installed in the server The following illustration shows the supported backplane configuration that you can use to support four drives This configuration consists of one 4x2 5 inch drive backplane and requires one SAS signal cable The following illustrations show the supported combination of drive backplane configur...

Страница 215: ...inch drive backplane and one 4x2 5 inch drive backplane and requires three SAS signal cables This configuration consists of one 4x2 5 inch drive backplane and one 8x1 8 inch drive backplane and requires three SAS signal cables 8 9 10 15 0 1 2 3 Empty Empty 1 8 SSD 1 8 SSD 1 8 SSD 1 8 SSD 1 8 SSD 1 8 SSD 1 8 SSD 1 8 SSD 2 5 HDD SSD 2 5 HDD SSD 2 5 HDD SSD 2 5 HDD SSD 1112 13 14 The following illust...

Страница 216: ...DD SSD 2 5 HDD SSD 2 5 HDD SSD 2 5 HDD SSD 2 5 HDD SSD 2 5 HDD SSD 2 5 HDD SSD 2 5 HDD SSD 1 8 SSD 1 8 SSD 1 8 SSD 1 8 SSD 1 8 SSD 1 8 SSD 1 8 SSD 1 8 SSD 22 23 This configuration consists of one 8x2 5 inch drive backplane and one 8x1 8 inch drive backplane and requires four SAS signal cables Empty 0 1 2 3 4 5 6 7 2 5 HDD SSD 2 5 HDD SSD 2 5 HDD SSD 2 5 HDD SSD 2 5 HDD SSD 2 5 HDD SSD 2 5 HDD SSD ...

Страница 217: ...4 27 26 25 28 29 1 8 SSD 1 8 SSD 1 8 SSD 1 8 SSD 1 8 SSD 1 8 SSD 1 8 SSD 1 8 SSD 30 31 This configuration consists of one 4x2 5 inch drive backplane and two 8x1 8 inch drive backplanes and requires five SAS signal cables 2 5 HDD SSD 0 1 2 3 Empty 2 5 HDD SSD 2 5 HDD SSD 2 5 HDD SSD 16 19 18 17 20 21 1 8 SSD 1 8 SSD 1 8 SSD 1 8 SSD 1 8 SSD 1 8 SSD 1 8 SSD 1 8 SSD 22 23 8 9 10 15 1 8 SSD 1 8 SSD 1 8...

Страница 218: ...wap 2 5 inch SATA drive kit in this configuration IDs for hot swap drives The drive ID that is assigned to each drive is printed on the front of the server The following illustrations show the locations of the IDs of the drives The ID numbers and the drive bay numbers are the same The following illustration shows the drive bay IDs on a 3 5 inch drive server model Figure 114 3 5 inch hot swap hard ...

Страница 219: ... 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 Figure 116 3 5 inch simple swap hard disk drive removal 0000 0000 000 000 000000000000000 000000000000000 000000000000000 000000000000000 000000000000000 000000000000000 000000000000000 000000000000000 000000000000000 Figure 117 2 5 inch simple swap hard disk drive removal Step 5 If you are instructed to return the drive foll...

Страница 220: ...lation 0000 0000 000 000 000000000000000 000000000000000 000000000000000 000000000000000 000000000000000 000000000000000 000000000000000 000000000000000 000000000000000 Figure 119 2 5 inch simple swap hard disk drive installation Step 4 Reinstall the filler panel that you removed Step 5 Turn on the peripheral devices and the server Removing a CD DVD drive Use this information to remove a DVD drive...

Страница 221: ... the drive Save the clip to use when you install the replacement drive Figure 121 DVD drive retention clip removal Step 6 If you are instructed to return the CD DVD drive follow all packaging instructions and use any packaging materials for shipping that are supplied to you Installing an optional CD DVD drive Use this information to install a DVD drive To install an optional CD DVD drive complete ...

Страница 222: ...ices Disconnect all power cords then disconnect all external cables from the server Step 3 Remove the top cover see Removing the server top cover on page 33 Step 4 Locate the blue release tab on the rear of the drive bay then while you press the tab push the CD DVD filler toward the front of the server Figure 122 DVD drive filler panel removal 208 Lenovo System x3530 M4 Installation and Service Gu...

Страница 223: ...TION When laser products such as CD ROMs DVD drives fiber optic devices or transmitters are installed note the following Do not remove the covers Removing the covers of the laser product could result in exposure to hazardous laser radiation There are no serviceable parts inside the device Use of controls or adjustments or performance of procedures other than those specified herein might result in ...

Страница 224: ... the new drive Figure 124 DVD drive retention clip installation Step 9 Align the drive in the drive bay and slide the drive into the CD DVD drive bay until the drive clicks into place Step 10 Reconnect the power cord and any cables that you removed Step 11 Turn on the peripheral devices and the server Removing the CD DVD cable Use this information to remove a CD DVD cable To remove the CD DVD cabl...

Страница 225: ...r Step 10 If you are instructed to return the CD DVD cable follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing the CD DVD cable Use this information to install a CD DVD cable To install the CD DVD cable complete the following cable Step 1 Read the safety information that begins in Safety on page v and Installation guidelines on page 31 ...

Страница 226: ... remove a fan complete the following steps Step 1 Read the safety information that begins in Safety on page v and Installation guidelines on page 31 Step 2 Turn off the server see Turning off the server on page 22 and all attached peripheral devices Disconnect all power cords then disconnect all external cables from the server Step 3 Remove the top cover see Removing the server top cover on page 3...

Страница 227: ... fans You must install the fifth and sixth fan when you install the second microprocessor Attention To ensure proper operation replace a failed fan within 30 seconds To install or replace a fan complete the following steps 1 Read the safety information that begins in Safety on page v and Installation guidelines on page 31 2 Turn off the server see Turning off the server on page 22 and all attached...

Страница 228: ...remove a dual inline memory module DIMM complete the following steps Step 1 Read the safety information that begins in Safety on page v and Installation guidelines on page 31 Step 2 Turn off the server see Turning off the server on page 22 and all attached peripheral devices Disconnect all power cords then disconnect all external cables as necessary to replace the device Step 3 Remove the top cove...

Страница 229: ...t the server supports and other information that you must consider when you install DIMMs Notes See Installing a memory module on page 35 for notes and information that you must consider when you install DIMMs Confirm that the server supports the DIMM that you are installing see http www lenovo com serverproven The following illustration shows the location of the DIMM connectors on the system boar...

Страница 230: ...ect all external cables as necessary to replace the device Step 3 Remove the top cover see Removing the server top cover on page 188 Step 4 Touch the static protective package that contains the DIMM to any unpainted metal surface on the outside of the server Then remove the DIMM from the package Step 5 Open the retaining clip on each end of the DIMM connector Attention To avoid breaking the retain...

Страница 231: ...on page 189 Step 12 Install the server in the rack cabinet see the Rack Installation Instructions that come with the server for instructions Step 13 Reconnect the power cord and any cables that you removed Step 14 Turn on the peripheral devices and the server Removing a ServeRAID Controller Use this information to remove an optional ServeRAID Controller To remove a ServeRAID adapter complete the f...

Страница 232: ...es If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code Notes You must install a ServeRAID adapter on PCI riser card assembly 2 When you install a ServeRAID adapter that has a RAID adapter battery in the server you must install the battery remotely in the remote battery tray see Installing a RAID adapter b...

Страница 233: ...connect cables to the adapter Be sure to route the signal cables as shown in the following illustration Secure the cables with any cable clips on the system board so that they do not get in the way or get damaged Step 7 Reinstall the PCI riser card assembly see Replacing a PCI riser card assembly on page 74 Step 8 Replace the cover see Replacing the server top cover on page 189 Step 9 Reconnect th...

Страница 234: ...structed to return the RAID adapter battery follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing a RAID adapter battery remotely in the server Use this information to install a RAID adapter battery remotely in the server When you install any ServeRAID adapter in the server that come with a RAID adapter battery the battery must be install...

Страница 235: ...tem board Step 4 Reinstall the PCI riser card assembly see Replacing a PCI riser card assembly on page 74 Step 5 Replace the cover see Replacing the server top cover on page 189 Step 6 Reconnect the power cord and any cables that you removed Step 7 Turn on the peripheral devices and the server Removing a USB embedded hypervisor flash device Use this information to remove a USB embedded hypervisor ...

Страница 236: ...SB hypervisor flash device connector Step 6 Slide the lockbar on the flash device connector to the unlocked position and pull the USB flash device out of the connector 222 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 237: ...ping that are supplied to you Replacing a USB embedded hypervisor flash device Use this information to install a USB embedded hypervisor flash device To install a hypervisor flash device complete the following steps Step 1 Read the safety information that begins in Safety on page v and Installation guidelines on page 31 Step 2 Align the USB flash device with the connector on the system board and p...

Страница 238: ... see Replacing the air baffle on page 192 Step 7 Install the cover see Replacing the server top cover on page 189 Step 8 Reconnect the power cord and any cables that you removed Step 9 Turn on the peripheral devices and the server Removing a hot swap power supply Use this information to remove a hot swap power supply When you remove or install a hot swap power supply observe the following precauti...

Страница 239: ... contact a service technician To remove a hot swap power supply complete the following steps Step 1 Read the safety information that begins in Safety on page v and Installation guidelines on page 31 Step 2 If only one power supply is installed turn off the server and peripheral devices and disconnect all power cords Step 3 If the server is in a rack at the back of the server pull back the cable ma...

Страница 240: ...ttp www ibm com systems bladecenter resources powerconfig html The server comes standard with one of the following power supplies that connects to power supply bay 1 The input voltage is 100 127 V ac or 200 240 V ac auto sensing 460 watt non hot swap power supply 460 watt hot swap power supply 675 watt high efficiency hot swap power supply Note You cannot mix 110 V ac and 220 V ac or 460 watt and ...

Страница 241: ...nent that has this label attached There are no serviceable parts inside these components If you suspect a with one of these parts contact a service technician To install a hot swap power supply complete the following steps 1 Read the safety information that begins in Safety on page v and Installation guidelines on page 31 2 Touch the static protective package that contains the hot swap power suppl...

Страница 242: ...ermit the connection of the earthed conductor of the dc supply circuit to the earthing conductor at the equipment This equipment is designed to permit the connection of the earthed conductor of the dc supply circuit to the earthing conductor at the equipment If this connection is made all of the following conditions must be met This equipment shall be connected directly to the dc supply system ear...

Страница 243: ...t that is to be attached to this product 2 Attach signal cables to the product 3 Attach power cords to the product For ac systems use appliance inlets For dc systems ensure correct polarity of 48 V dc connections RTN is and 48 V dc is Earth ground should use a two hole lug for safety 4 Attach signal cables to other devices 5 Connect power cords to their sources 6 Turn ON all the power sources 1 Tu...

Страница 244: ...per wire conductors only See the specifications in the product documentation for the required wire size See the specifications in the product documentation for the required torque values for the wiring terminal screws Important Be sure to read the multilingual safety instructions on the CD that comes with the server before you use the product To remove a hot swap dc power supply complete the follo...

Страница 245: ...supplies Do not use both ac and dc power supplies in the same server Install up to two dc power supplies or up to two ac power supplies but not a combination Power supply 1 is the default primary power supply If power supply 1 fails you must replace the power supply with the same wattage immediately You can order an optional power supply for redundancy These power supplies are designed for paralle...

Страница 246: ...equipment Switching or disconnecting devices shall not be in the earthed circuit conductor between the dc source and the point of connection of the earthing electrode conductor Statement 31 DANGER Electrical current from power telephone and communication cables is hazardous To avoid a shock hazard Do not connect or disconnect any cables or perform installation maintenance or reconfiguration of thi...

Страница 247: ...moving power modules and I O modules does not turn off electrical current to the product The product also might have more than one power cord To remove all electrical current from the product make sure that all power cords are disconnected from the power source Statement 34 CAUTION To reduce the risk of electric shock or energy hazards This equipment must be installed by trained service personnel ...

Страница 248: ...ce personnel install or remove the 48 volt power cable Step 1 Read the safety information that begins in Safety on page v and Installation guidelines on page 31 Step 2 Touch the static protective package that contains the hot swap power supply to any unpainted metal surface on the server then remove the power supply from the package and place it on a static protective surface Step 3 Turn off the c...

Страница 249: ... wires The ring terminals must be UL approved and must accommodate the wires that are described in note The minimum nominal thread diameter of a pillar or stud type of terminal must be 4 mm for a screw type of terminal the diameter must be 5 0 mm Step 9 Turn on the circuit breaker for the dc power source to which the new power supply is connected Step 10 Make sure that the green power LEDs on the ...

Страница 250: ...ear the power supplies Figure 145 Redundant power information label Removing the fixed power supply Use this information to remove the fixed power supply Note You must turn off the server before removing or replacing the fixed power supply When you remove or install a power supply observe the following precautions Statement 5 236 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 251: ...one of these parts contact a service technician To remove the fixed power supply complete the following steps Step 1 Read the safety information that begins in Safety on page v and Installation guidelines on page 31 Step 2 Turn off the server see Turning off the server on page 22 and all attached peripheral devices Disconnect all power cords then disconnect all external cables as necessary to repl...

Страница 252: ...ted to return the power supply follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing the fixed power supply Use this information to install the fixed power supply Note You must turn off the server before removing or replacing the fixed power supply Statement 5 CAUTION The power control button on the device and the power switch on the powe...

Страница 253: ...pply complete the following steps 1 Read the safety information that begins in Safety on page v and Installation guidelines on page 31 2 Touch the static protective package that contains the power supply to any unpainted metal surface on the server then remove the power supply from the package and place it on a static protective surface 3 Orient the power supply as shown in the following illustrat...

Страница 254: ...ide the retention tabs into the slots Make sure all retention tabs are engaged in the slots Figure 148 Fixed power supply installation 6 Install the screw and the filler to secure the power supply in the chassis 240 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 255: ...new power supply to the power cord connector on the power supply 11 Connect the other end of the power cord to a properly grounded electrical outlet 12 Make sure that the ac power LED and the dc power LED on the power supply are lit indicating that the power supply is operating correctly Removing a PCI riser card assembly Use this information to remove a PCI riser card assembly To remove a PCI ris...

Страница 256: ...000 000000 000000 000000 000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 Figure 150 PCI riser card assembly removal Step 6 Remove the adapter if necessary from the PCI riser card assembly see Removing an adapte...

Страница 257: ...000000 00000000000000000000 00000000000000000000 00000000000000000000 00000000000000000000 Figure 151 PCI riser card assembly installation Step 5 Install the cover see Replacing the server top cover on page 189 Step 6 Reconnect the external cables then reconnect the power cords and turn on the peripheral devices and the server Removing the operator information panel assembly Use the information to...

Страница 258: ...e assembly out of the server Step 7 If you are instructed to return the operator information panel assembly follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing the operator information panel assembly Use the information to replace the operator information panel assembly To install the operator information panel complete the following st...

Страница 259: ... to the connectors on the system board Route the signal cable as shown in the following illustration Secure the cable with any cable clips on the chassis Figure 154 Signal cable installation Step 4 Remove the air baffle see Removing the air baffle on page 192 Step 5 Inside the server connect the cable to the rear of the operator information panel assembly Step 6 Reinstall the air baffle see Replac...

Страница 260: ...mestic waste They will be taken back free of charge by the manufacturer distributor or representative to be recycled or disposed of in a proper manner To order replacement batteries call 1 800 IBM SERV within the United States and 1 800 465 7999 or 1 800 465 6666 within Canada Outside the U S and Canada call your support center or business partner Note After you replace the battery you must reconf...

Страница 261: ...l power cords then disconnect all external cables as necessary to replace the device Step 3 Remove the top cover see Removing the server top cover on page 33 Step 4 Remove PCI riser card assembly 1 from the server see Removing a PCI riser card assembly on page 241 Step 5 Remove the system board battery a Use one finger to push the battery horizontally out of its housing Figure 156 System battery r...

Страница 262: ...d Canada call your Lenovo marketing representative or authorized reseller After you replace the system board battery you must reconfigure the server and reset the system date and time To avoid possible danger read and follow the following safety statement Statement 2 CAUTION When replacing the lithium battery use only Part Number 33F8354 or an equivalent type battery recommended by the manufacture...

Страница 263: ...into its socket and press the battery press the battery toward the housing until it clicks into place Make sure that the battery clip holds the battery securely Step 3 Install PCI riser card assembly 1 see Replacing a PCI riser card assembly on page 242 Step 4 Install the cover see Replacing the server top cover on page 189 Step 5 Reconnect the external cables then reconnect the power cords and tu...

Страница 264: ...and Installation guidelines on page 31 Step 2 Turn off the server see Turning off the server on page 22 and all attached peripheral devices Disconnect all power cords then disconnect all external cables as necessary to replace the device Step 3 Remove the server cover see Removing the server top cover on page 188 Step 4 Disconnect the USB cable from the connector on the rear of the USB assembly St...

Страница 265: ...crews removal Step 8 If you are instructed to return the front USB connector board follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing the front USB connector board Use this information to replace the front USB connector board To replace the front USB connector board complete the following steps Chapter 6 Removing and replacing structur...

Страница 266: ...ure 162 USB assembly screws installation Step 3 Install the screws to secure the USB connector board to the USB assembly Step 4 From the front of the server slide the USB assembly into the USB slot until it clicks into place 0000000000000000 0000000000000000 0000000000000000 0000000000000000 0000000000000000 0000000000000000 0000000000000000 0000000000000000 0000000000000000 Figure 163 USB assembl...

Страница 267: ...ollowing steps Step 1 Read the safety information that begins in Safety on page v and Installation guidelines on page 31 Step 2 Turn off the server see Turning off the server on page 22 and all attached peripheral devices Disconnect all power cords then disconnect all external cables as necessary to replace the device Step 3 Remove the server cover see Removing the server top cover on page 188 Ste...

Страница 268: ...omplete the following steps Step 1 Read the safety information that begins in Safety on page v and Installation guidelines on page 31 Step 2 Align the video connector with the slot on the server and install the two screws to secure it to the server Note Refer to the illustrations below for 2 5 inch and 3 5 inch hard disk drive bays models respectively Depending on your server model align the video...

Страница 269: ... steps Step 1 Read the safety information that begins in Safety on page v and Installation guidelines on page 31 Step 2 Turn off the server see Turning off the server on page 22 and all attached peripheral devices Disconnect all power cords then disconnect all external cables as necessary to replace the device Step 3 Remove the server cover see Removing the server top cover on page 188 Step 4 Remo...

Страница 270: ...e the safety cover from the top of the power interposer card Step 10 Remove the screws that secure the power interposer card to the chassis Step 11 Disconnect the power cable from the power interposer card then remove the power interposer card out of the server 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 00000 00000 00000 Figure 167 Power interposer c...

Страница 271: ...placing the power interposer card assembly Use this information to replace the power interposer card assembly To install the power interposer card assembly complete the following steps Step 1 Read the safety information that begins in Safety on page v and Installation guidelines on page 31 Step 2 Reconnect the power cable to the power interposer card Step 3 Align the screw holes on the power inter...

Страница 272: ...igure 169 Power interposer card assembly installation 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 000000000000 00000 00000 00000 Figure 170 Power interposer card assembly installation with advanced remote battery holder 258 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 273: ... the safety information that begins in Safety on page v and Installation guidelines on page 31 Step 2 Turn off the server see Turning off the server on page 22 and all attached peripheral devices Disconnect all power cords then disconnect all external cables as necessary to replace the device Step 3 Remove the server cover see Removing the server top cover on page 188 Step 4 Pull the drives and fi...

Страница 274: ...0000000000000000000000000 00000000000000000000000000 00000000000000000000000000 Figure 172 Hot swap drive backplane installation 3 Reconnect the configuration power and SAS signal cables to the connectors on the backplane Route the cables as shown in the following illustration 4 Reinstall the drives and filler panels 5 Reinstall the cover see Replacing the server top cover on page 189 6 Reconnect ...

Страница 275: ...ackplate assembly follow all packaging instructions and use any packaging materials for shipping that are supplied to you Replacing the simple swap SATA drive backplate assembly Use this information to replace the simple swap drive SATA drive backplate assembly To install the replacement simple swap SATA drive and backplate assembly complete the following steps Note The simple swap SATA drive and ...

Страница 276: ...a Tier 2 CRU yourself or request Lenovo to install it at no additional charge under the type of warranty service that is designated for your server The illustrations in this document might differ slightly from your hardware Removing a microprocessor and heat sink Use this information to remove a microprocessor and heat sink Attention Be extremely careful the pins on the socket are fragile Any dama...

Страница 277: ...emory module from DIMM connector 5 If you are removing microprocessor 2 remove the memory module from DIMM connector 12 See Removing a memory module on page 214 for instructions Step 7 Loosen the screws on the heat sink with a screwdriver alternating among the screws until they are loose If possible each screw should be rotated two full rotations at a time Step 8 Gently pull the heat sink off the ...

Страница 278: ...u can pick up or release the microprocessor by twisting the microprocessor installation tool handle Figure 177 Microprocessor tool attachment Step 12 Carefully lift the microprocessor straight up and out of the socket and place it on a static protective surface Remove the microprocessor from the installation tool by twisting the handle counterclockwise Attention Do not touch the pins on the socket...

Страница 279: ...l the pins on the socket are fragile Any damage to the pins may require replacing the system board Use the microprocessor installation tool that came with the new microprocessor to remove the microprocessor from the server Failure to use the microprocessor tool may cause damage to the pins on the socket Any damage to the pins may require replacing the system board To install an additional micropro...

Страница 280: ...al d Twist the handle of the microprocessor installation tool counterclockwise so that it is in the open position e Align the triangle alignment mark on the microprocessor with the triangle alignment mark on the microprocessor installation tool then place the microprocessor on the bottom of the tool so that the tool can grasp the microprocessor correctly onto the bottom of the installation tool f ...

Страница 281: ... to insert the microprocessor into the socket Installation tool Handle Figure 183 Microprocessor installation Attention Do not press the microprocessor into the socket Do not touch exposed pins of the microprocessor socket The pins on the socket are fragile Any damage to the pins may require replacing the system board Make sure that the microprocessor is oriented and aligned correctly in the socke...

Страница 282: ...tom of the heat sink after you remove the plastic cover Touching the thermal grease will contaminate it See Thermal grease on page 55 for more information b Align the screws on the heat sink with the screw holes on the system board then place the heat sink on the microprocessor with the thermal grease side down Figure 184 Heat sink installation c Press firmly on the captive screws and tighten them...

Страница 283: ...ing requirements are met The thermal grease on the heat sink and microprocessor is not contaminated Additional thermal grease is not added to the existing thermal grease on the heat sink and microprocessor Notes Read the Safety information in Safety on page v Read the Installation guidelines on page 31 Read Handling static sensitive devices on page 33 To replace damaged or contaminated thermal gre...

Страница 284: ... new system board For more information on Features on Demand FoD including instructions for automating the activation and installation of the activation key by using ToolsCenter or Systems Director see the Features on Demand User s Guide at http www ibm com systems x fod under the Help section 2 When you replace the system board you must either update the server with the latest firmware or restore...

Страница 285: ...ct all cables from the system board Refer to Internal cable routing on page 161 for more information Failing to release them before removing the cables will damage the cable sockets on the system board The cable sockets on the system board are fragile Any damage to the cable sockets may require replacing the system board Step 7 Remove the DIMMs from the system board and set them aside on a static ...

Страница 286: ...rs from the microprocessor sockets on the new system board and place them on the microprocessor sockets of the old system board that you are removing Figure 189 Socket cover removal Step 10 Loosen the nine screws that secure the system board to the chassis Figure 190 Loosen screws Step 11 Slightly lift the system board at the side that is near the CPU1_PWR to create a small angle of elevation betw...

Страница 287: ...ard toward to the fan cage Step 13 Grasp the system board on both the cable clip near the microprocessor 2 and PCI riser card connector 1 Then slightly lift the system board to create a small angle of elevation by leaning the edge against the partition of the power supply between the system board and chassis Chapter 6 Removing and replacing structural parts 273 ...

Страница 288: ...e system board by placing both hands diagonally and remove it from the chassis Be careful to avoid damage any surrounding components or bend the pin inside the microprocessor socket Figure 194 System board removal 274 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 289: ... get pinched when you reinstall the system board In addition make sure the cables are inserted into the relevant cable clips 3 When you replace the system board you must either update the server with the latest firmware or restore the pre existing firmware that the customer provides on a diskette or CD image Make sure that you have the latest firmware or a copy of the pre existing firmware before ...

Страница 290: ...put output connectors of the system board away from the hard disk bays Figure 196 System board alignment Step 4 Make sure the eight standoffs are aligned with the corresponding captive screw holes on the system board 276 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 291: ... the system board with the screw holes on the chassis and install the screws to secure the system board to the chassis Figure 198 System board installation Step 6 Reconnect the cables that you disconnected earlier to the system board Chapter 6 Removing and replacing structural parts 277 ...

Страница 292: ...eplacing a PCI riser card assembly on page 74 Step 12 Reinstall the air baffle see Replacing the air baffle on page 192 Step 13 Reinstall the cover see Replacing the server top cover on page 189 Step 14 Reconnect the power cords and any cables that you removed Step 15 Turn on the peripheral devices and the server Important Perform the following updates Either update the server with the latest RAID...

Страница 293: ... of the level of concern for the condition In the system event log severity is abbreviated to the first character The following severities can be displayed Info The event was recorded for audit purposes usually a user action or a change of states that is normal behavior Warning The event is not as severe as an error but if possible the condition should be corrected before it becomes an error It mi...

Страница 294: ...and messages that might not apply to this machine type and model The following is the list of Integrated Management Module II IMM2 error messages and suggested actions to correct the detected server problems For more information about Integrated Management Module II IMM2 see the Integrated Management Module II User s Guide at www ibm com support entry portal docdisplay lndocid MIGR 5089484 brandin...

Страница 295: ...sure that the certificate that you are importing is correct and properly generated 40000003 00000000 Ethernet Data Rate modified from arg1 to arg2 by user arg3 This message is for the use case where a user modifies the Ethernet Port data rate May also be shown as 4000000300000000 or 0x4000000300000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM...

Страница 296: ...rg2 by user arg3 This message is for the use case where a user modifies the Ethernet Port MTU setting May also be shown as 4000000500000000 or 0x4000000500000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0005 User Response Information only no action is required 40000006 00000000 Ethernet locally administered MAC addr...

Страница 297: ...s or disabled the ethernet interface May also be shown as 4000000700000000 or 0x4000000700000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0007 User Response Information only no action is required 40000008 00000000 Hostname set to arg1 by user arg2 This message is for the use case where user modifies the Hostname of ...

Страница 298: ...May also be shown as 4000000900000000 or 0x4000000900000000 Severity Info Serviceable No Automatically notify support No Alert Category System IMM Network event SNMP Trap ID 37 CIM Information Prefix IMM ID 0009 User Response Information only no action is required 4000000a 00000000 IP subnet mask of network interface modified from arg1 to arg2 by user arg3 This message is for the use case where a ...

Страница 299: ...t Controller May also be shown as 4000000b00000000 or 0x4000000b00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0011 User Response Information only no action is required 4000000c 00000000 OS Watchdog response arg1 by arg2 This message is for the use case where an OS Watchdog has been enabled or disabled by a user ...

Страница 300: ... notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0013 User Response Complete the following steps until the problem is solved 1 Make sure that the IMM network cable is connected 2 Make sure that there is a DHCP server on the network that can assign an IP address to the IMM 4000000e 00000000 Remote Login Successful Login ID arg1 from arg2 at IP address arg3 This mess...

Страница 301: ...0000f00000000 or 0x4000000f00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0015 User Response Information only no action is required 40000010 00000000 Security Userid arg1 had arg2 login failures from WEB client at IP address arg3 This message is for the use case where a user has failed to log in to a Management C...

Страница 302: ...0 or 0x4000001100000000 Severity Warning Serviceable No Automatically notify support No Alert Category System Remote Login SNMP Trap ID 30 CIM Information Prefix IMM ID 0017 User Response Complete the following steps until the problem is solved 1 Make sure that the correct login ID and password are being used 2 Have the system administrator reset the login ID or password 40000012 00000000 Remote a...

Страница 303: ...to a Management Controller from a telnet session May also be shown as 4000001300000000 or 0x4000001300000000 Severity Info Serviceable No Automatically notify support No Alert Category System Remote Login SNMP Trap ID 30 CIM Information Prefix IMM ID 0019 User Response Make sure that the correct login ID and password are being used 40000014 00000000 The arg1 on system arg2 cleared by user arg3 Thi...

Страница 304: ...e shown as 4000001500000000 or 0x4000001500000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0021 User Response Information only no action is required 40000016 00000000 ENET arg1 DHCP HSTN arg2 DN arg3 IP arg4 SN arg5 GW arg6 DNS1 arg7 This message is for the use case where a Management Controller IP address and confi...

Страница 305: ...tatically using user data May also be shown as 4000001700000000 or 0x4000001700000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0023 User Response Information only no action is required 40000018 00000000 LAN Ethernet arg1 interface is no longer active This message is for the use case where a Management Controller eth...

Страница 306: ...active May also be shown as 4000001900000000 or 0x4000001900000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0025 User Response Information only no action is required 4000001a 00000000 DHCP setting changed to arg1 by user arg2 This message is for the use case where a user changes the DHCP setting May also be shown as...

Страница 307: ...y also be shown as 4000001b00000000 or 0x4000001b00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0027 User Response Information only no action is required 4000001c 00000000 Watchdog arg1 Screen Capture Occurred This message is for the use case where an operating system error has occurred and the screen was capture...

Страница 308: ...en capture failed May also be shown as 4000001d00000000 or 0x4000001d00000000 Severity Error Serviceable No Automatically notify support No Alert Category System other SNMP Trap ID 22 CIM Information Prefix IMM ID 0029 User Response Complete the following steps until the problem is solved 1 Reconfigure the watchdog timer to a higher value 2 Make sure that the IMM Ethernet over USB interface is ena...

Страница 309: ...e updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 4000001f 00000000 Please ensure that the Management Controller arg1 is flashed with the correct firmware The Management Controller is unable to match its firmware to the server This message is for the use case where a Management Controller firm...

Страница 310: ...o default values May also be shown as 4000002000000000 or 0x4000002000000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0032 User Response Information only no action is required 40000021 00000000 Management Controller arg1 clock has been set from NTP server arg2 This message is for the use case where a Management Cont...

Страница 311: ...D 0034 User Response Complete the following steps until the problem is solved 1 Make sure that the certificate that you are importing is correct 2 Try to import the certificate again 40000023 00000000 Flash of arg1 from arg2 succeeded for user arg3 This message is for the use case where a user has successfully flashed the firmware component MC Main Application MC Boot ROM BIOS Diagnostics System P...

Страница 312: ...y Info Serviceable No Automatically notify support No Alert Category System other SNMP Trap ID 22 CIM Information Prefix IMM ID 0036 User Response Information only no action is required 40000025 00000000 The arg1 on system arg2 is 75 full This message is for the use case where a Management Controller Event Log on a system is 75 full May also be shown as 4000002500000000 or 0x4000002500000000 Sever...

Страница 313: ...og 75 full SNMP Trap ID 35 CIM Information Prefix IMM ID 0038 User Response To avoid losing older log entries save the log as a text file and clear the log 40000027 00000000 Platform Watchdog Timer expired for arg1 This message is for the use case when an implementation has detected a Platform Watchdog Timer Expired May also be shown as 4000002700000000 or 0x4000002700000000 Severity Error Service...

Страница 314: ...Alert May also be shown as 4000002800000000 or 0x4000002800000000 Severity Info Serviceable No Automatically notify support No Alert Category System other SNMP Trap ID 22 CIM Information Prefix IMM ID 0040 User Response Information only no action is required 40000029 00000000 Security Userid arg1 had arg2 login failures from an SSH client at IP address arg3 This message is for the use case where a...

Страница 315: ... where a specific type of firmware mismatch has been detected May also be shown as 4000002a00000000 or 0x4000002a00000000 Severity Error Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0042 User Response Reflash the IMM firmware to the latest version 4000002b 00000000 Domain name set to arg1 Domain name set by user May also b...

Страница 316: ...o Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0044 User Response Information only no action is required 4000002d 00000000 DDNS setting changed to arg1 by user arg2 DDNS setting changed by user May also be shown as 4000002d00000000 or 0x4000002d00000000 Severity Info Serviceable No Automatically notify support No Alert Category none ...

Страница 317: ...le No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0046 User Response Information only no action is required 4000002f 00000000 IPv6 enabled by user arg1 IPv6 protocol is enabled by user May also be shown as 4000002f00000000 or 0x4000002f00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Inform...

Страница 318: ...one SNMP Trap ID CIM Information Prefix IMM ID 0048 User Response Information only no action is required 40000031 00000000 IPv6 static IP configuration enabled by user arg1 IPv6 static address assignment method is enabled by user May also be shown as 4000003100000000 or 0x4000003100000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information ...

Страница 319: ...refix IMM ID 0050 User Response Information only no action is required 40000033 00000000 IPv6 stateless auto configuration enabled by user arg1 IPv6 statless auto assignment method is enabled by user May also be shown as 4000003300000000 or 0x4000003300000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0051 User Respon...

Страница 320: ...sponse Information only no action is required 40000035 00000000 IPv6 DHCP disabled by user arg1 IPv6 DHCP assignment method is disabled by user May also be shown as 4000003500000000 or 0x4000003500000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0053 User Response Information only no action is required 40000036 00000...

Страница 321: ...00000 ENET arg1 IPv6 LinkLocal HstName arg2 IP arg3 Pref arg4 IPv6 Link Local address is active May also be shown as 4000003700000000 or 0x4000003700000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0055 User Response Information only no action is required 40000038 00000000 ENET arg1 IPv6 Static HstName arg2 IP arg3 P...

Страница 322: ...ss is active May also be shown as 4000003900000000 or 0x4000003900000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0057 User Response Information only no action is required 4000003a 00000000 IPv6 static address of network interface modified from arg1 to arg2 by user arg3 A user modifies the IPv6 static address of a M...

Страница 323: ...003b00000000 Severity Warning Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0059 User Response Complete the following steps until the problem is solved 1 Make sure that the IMM network cable is connected 2 Make sure that there is a DHCPv6 server on the network that can assign an IP address to the IMM 4000003c 00000000 Platform Watchdo...

Страница 324: ... RNDIS or cdc_ether device driver for the operating system 4 Disable the watchdog 5 Check the integrity of the installed operating system 4000003d 00000000 Telnet port number changed from arg1 to arg2 by user arg3 A user has modified the telnet port number May also be shown as 4000003d00000000 or 0x4000003d00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SN...

Страница 325: ...y no action is required 4000003f 00000000 Web HTTP port number changed from arg1 to arg2 by user arg3 A user has modified the Web HTTP port number May also be shown as 4000003f00000000 or 0x4000003f00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0063 User Response Information only no action is required 40000040 00...

Страница 326: ... arg2 by user arg3 A user has modified the CIM HTTP port number May also be shown as 4000004100000000 or 0x4000004100000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0065 User Response Information only no action is required 40000042 00000000 CIM XML HTTPS port number changed from arg1 to arg2 by user arg3 A user has ...

Страница 327: ...er May also be shown as 4000004300000000 or 0x4000004300000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0067 User Response Information only no action is required 40000044 00000000 SNMP Traps port number changed from arg1 to arg2 by user arg3 A user has modified the SNMP Traps port number May also be shown as 4000004...

Страница 328: ...e shown as 4000004500000000 or 0x4000004500000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0069 User Response Information only no action is required 40000046 00000000 Remote Presence port number changed from arg1 to arg2 by user arg3 A user has modified the Remote Presence port number May also be shown as 4000004600...

Страница 329: ...000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0071 User Response Information only no action is required 40000048 00000000 Inventory data changed for device arg1 new device data hash arg2 new master data hash arg3 Something has caused the physical inventory to change May also be shown as 4000004800000000 or 0x40000...

Страница 330: ...000 or 0x4000004900000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0073 User Response Information only no action is required 4000004a 00000000 SNMP arg1 disabled by user arg2 A user disabled SNMPv1 or SNMPv3 or Traps May also be shown as 4000004a00000000 or 0x4000004a00000000 Severity Info Serviceable No Automatical...

Страница 331: ...tically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0075 User Response Information only no action is required 4000004c 00000000 LDAP Server configuration set by user arg1 SelectionMethod arg2 DomainName arg3 Server1 arg4 Server2 arg5 Server3 arg6 Server4 arg7 A user changed the LDAP server configuration May also be shown as 4000004c00000000 or 0x4000004c0000000...

Страница 332: ...000 or 0x4000004d00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0077 User Response Information only no action is required 4000004e 00000000 Serial Redirection set by user arg1 Mode arg2 BaudRate arg3 StopBits arg4 Parity arg5 SessionTerminateSequence arg6 A user configured the Serial Port mode May also be shown a...

Страница 333: ... No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0079 User Response Information only no action is required 40000050 00000000 Server General Settings set by user arg1 Name arg2 Contact arg3 Location arg4 Room arg5 RackID arg6 Rack U position arg7 A user configured the Location setting May also be shown as 4000005000000000 or 0x4000005000000000 Sever...

Страница 334: ...e No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0081 User Response Information only no action is required 40000052 00000000 Server arg1 scheduled for arg2 at arg3 by user arg4 A user configured a Server Power action at a specific time May also be shown as 4000005200000000 or 0x4000005200000000 Severity Info Serviceable No Automatically notify sup...

Страница 335: ...o Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0083 User Response Information only no action is required 40000054 00000000 Server arg1 arg2 cleared by user arg3 A user cleared a Server Power Action May also be shown as 4000005400000000 or 0x4000005400000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap I...

Страница 336: ...tify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0085 User Response Information only no action is required 40000056 00000000 SMTP Server set by user arg1 to arg2 arg3 A user configured the SMTP server May also be shown as 4000005600000000 or 0x4000005600000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information...

Страница 337: ...0058 00000000 DNS servers set by user arg1 UseAdditionalServers arg2 PreferredDNStype arg3 IPv4Server1 arg4 IPv4Server2 arg5 IPv4Server3 arg6 IPv6Server1 arg7 IPv6Server2 arg8 IPv6Server3 arg9 A user configures the DNS servers May also be shown as 4000005800000000 or 0x4000005800000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Pre...

Страница 338: ...equired 4000005a 00000000 LAN over USB Port Forwarding set by user arg1 ExternalPort arg2 USB LAN port arg3 A user configured USB LAN port forwarding May also be shown as 4000005a00000000 or 0x4000005a00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0090 User Response Information only no action is required 4000005b...

Страница 339: ...g1 by user arg2 A user enables or disables Secure CIM XML services May also be shown as 4000005c00000000 or 0x4000005c00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0092 User Response Information only no action is required 4000005d 00000000 Secure LDAP arg1 by user arg2 A user enables or disables Secure LDAP serv...

Страница 340: ...00 or 0x4000005e00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0094 User Response Information only no action is required 4000005f 00000000 Server timeouts set by user arg1 EnableOSWatchdog arg2 OSWatchdogTimout arg3 EnableLoaderWatchdog arg4 LoaderTimeout arg5 A user configures Server Timeouts May also be shown a...

Страница 341: ...ay also be shown as 4000006000000000 or 0x4000006000000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0096 User Response Information only no action is required 40000061 00000000 License key for arg1 removed by user arg2 A user removes a License Key May also be shown as 4000006100000000 or 0x4000006100000000 Severity I...

Страница 342: ...rt No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0098 User Response Information only no action is required 40000063 00000000 Global Login Account Security set by user arg1 PasswordRequired arg2 PasswordExpirationPeriod arg3 MinimumPasswordReuseCycle arg4 MinimumPasswordLength arg5 MinimumPasswordChangeInterval arg6 MaxmumLoginFailures arg7 LockoutAfterMaxFailures arg8 MinimumDi...

Страница 343: ... May also be shown as 4000006400000000 or 0x4000006400000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0100 User Response Information only no action is required 40000065 00000000 User arg1 removed A user account was deleted May also be shown as 4000006500000000 or 0x4000006500000000 Severity Info Appendix A Integrate...

Страница 344: ...e shown as 4000006600000000 or 0x4000006600000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0102 User Response Information only no action is required 40000067 00000000 User arg1 role set to arg2 A user account role assigned May also be shown as 4000006700000000 or 0x4000006700000000 Severity Info Serviceable No 330 L...

Страница 345: ...erviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0104 User Response Information only no action is required 40000069 00000000 User arg1 for SNMPv3 set AuthenticationProtocol arg2 PrivacyProtocol arg3 AccessType arg4 HostforTraps arg5 User account SNMPv3 settings changed May also be shown as 4000006900000000 or 0x4000006900000000 Severity I...

Страница 346: ...verity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0106 User Response Information only no action is required 4000006b 00000000 SSH Client key imported for user arg1 from arg2 User imported an SSH Client key May also be shown as 4000006b00000000 or 0x4000006b00000000 Severity Info Serviceable No Automatically notify support No A...

Страница 347: ...upport No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0108 User Response Information only no action is required 4000006d 00000000 Management Controller arg1 Configuration saved to a file by user arg2 A user saves a Management Controller configuration to a file May also be shown as 4000006d00000000 or 0x4000006d00000000 Severity Info Serviceable No Automatically notify support No...

Страница 348: ...lly notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0110 User Response Information only no action is required 4000006f 00000000 Alert Recipient Number arg1 updated Name arg2 DeliveryMethod arg3 Address arg4 IncludeLog arg5 Enabled arg6 EnabledAlerts arg7 AllowedFilters arg8 A user adds or updates an Alert Recipient May also be shown as 4000006f00000000 or 0x4000006...

Страница 349: ...ify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0112 User Response Information only no action is required 40000071 00000000 The power cap value changed from arg1 watts to arg2 watts by user arg3 Power Cap values changed by user May also be shown as 4000007100000000 or 0x4000007100000000 Severity Info Serviceable No Automatically notify support No Alert Category none S...

Страница 350: ...MP Trap ID CIM Information Prefix IMM ID 0114 User Response Information only no action is required 40000073 00000000 The maximum power cap value changed from arg1 watts to arg2 watts Maximum Power Cap value changed May also be shown as 4000007300000000 or 0x4000007300000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0...

Страница 351: ...nformation only no action is required 40000075 00000000 The measured power value exceeded the power cap value Power exceeded cap May also be shown as 4000007500000000 or 0x4000007500000000 Severity Warning Serviceable No Automatically notify support No Alert Category Warning Power SNMP Trap ID 164 CIM Information Prefix IMM ID 0117 User Response Information only no action is required 40000076 0000...

Страница 352: ...apping was activated by user arg1 Power capping activated by user May also be shown as 4000007700000000 or 0x4000007700000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0119 User Response Information only no action is required 40000078 00000000 Power capping was deactivated by user arg1 Power capping deactivated by us...

Страница 353: ...r May also be shown as 4000007900000000 or 0x4000007900000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0121 User Response Information only no action is required 4000007a 00000000 Static Power Savings mode has been turned off by user arg1 Static Power Savings mode turned off by user May also be shown as 4000007a00000...

Страница 354: ...so be shown as 4000007b00000000 or 0x4000007b00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0123 User Response Information only no action is required 4000007c 00000000 Dynamic Power Savings mode has been turned off by user arg1 Dynamic Power Savings mode turned off by user May also be shown as 4000007c00000000 or...

Страница 355: ... 4000007d00000000 or 0x4000007d00000000 Severity Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0125 User Response Information only no action is required 4000007e 00000000 External throttling occurred External throttling occurred May also be shown as 4000007e00000000 or 0x4000007e00000000 Severity Info Serviceable No Automatically...

Страница 356: ... Info Serviceable No Automatically notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0127 User Response Information only no action is required 40000080 00000000 Remote Control session started by user arg1 in arg2 mode Remote Control session started May also be shown as 4000008000000000 or 0x4000008000000000 Severity Info Serviceable No Automatically notify support No...

Страница 357: ...notify support No Alert Category none SNMP Trap ID CIM Information Prefix IMM ID 0129 User Response Information only no action is required 40000082 00000000 The measured power value has returned below the power cap value Power exceeded cap recovered May also be shown as 4000008200000000 or 0x4000008200000000 Severity Info Serviceable No Automatically notify support No Alert Category Warning Power ...

Страница 358: ...rt Category Warning Power SNMP Trap ID 164 CIM Information Prefix IMM ID 0131 User Response Information only no action is required 40000084 00000000 IMM firmware mismatch between nodes arg1 and arg2 Please attempt to flash the IMM firmware to the same level on all nodes A mismatch of IMM firmware has been detected between nodes May also be shown as 4000008400000000 or 0x4000008400000000 Severity E...

Страница 359: ...00000 Severity Error Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix IMM ID 0133 User Response Attempt to flash the FPGA firmware to the same level on all nodes 40000086 00000000 Test Call Home Generated by user arg1 Test Call Home generated by user May also be shown as 4000008600000000 or 0x4000008600000000 Severity Info Serviceabl...

Страница 360: ...ponse IBM Support will address the problem 40000088 00000000 Management Controller arg1 Configuration restoration from a file by user arg2 completed This message is for the use case where a user restores a Management Controller configuration from a file and it completes May also be shown as 4000008800000000 or 0x4000008800000000 Severity Info Serviceable No Automatically notify support No Alert Ca...

Страница 361: ...esponse 1 Turn off the server and disconnect it from the power source You must disconnect the server from ac power to reset the IMM 2 After 45 seconds reconnect the server to the power source and turn on the server 3 Retry the operation 4000008a 00000000 Management Controller arg1 Configuration restoration from a file by user arg2 failed to start This message is for the use case where a user resto...

Страница 362: ...s changed May also be shown as 4000008b00000000 or 0x4000008b00000000 Severity Info Serviceable No Automatically notify support No Alert Category System IMM Network event SNMP Trap ID 37 CIM Information Prefix IMM ID 0139 User Response Information only no action is required 80010002 0701ffff Numeric sensor NumericSensorElementName going low lower non critical has asserted CMOS Battery This message...

Страница 363: ... 0480 User Response If the specified sensor is CMOS battery replace the system battery If the specified sensor is Planar 3 3V or Planar 5V trained technician only replace the system board If the specified sensor is Planar 12V complete the following steps until the problem is solved 1 Check power supply n LED 2 Remove the failing power supply 3 Follow actions in Power Problems and Solving Power Pro...

Страница 364: ...eric sensor NumericSensorElementName going low lower critical has asserted Fan 1Ab Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has asserted May also be shown as 800102041d02ffff or 0x800102041d02ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefi...

Страница 365: ...CIM Information Prefix PLAT ID 0480 User Response 1 Reseat the failing fan n which is indicated by a lit LED near the fan connector on the system board 2 Replace the failing fan n fan number 80010204 1d04ffff Numeric sensor NumericSensorElementName going low lower critical has asserted Fan 1Bb Tach This message is for the use case when an implementation has detected a Lower Critical sensor going l...

Страница 366: ...x800102041d05ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0480 User Response 1 Reseat the failing fan n which is indicated by a lit LED near the fan connector on the system board 2 Replace the failing fan n fan number 80010204 1d06ffff Numeric sensor NumericSensorElementName going low lower cr...

Страница 367: ...cal has asserted Fan 2Ba Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has asserted May also be shown as 800102041d07ffff or 0x800102041d07ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0480 User Response 1 Reseat the failing fan n wh...

Страница 368: ...Response 1 Reseat the failing fan n which is indicated by a lit LED near the fan connector on the system board 2 Replace the failing fan n fan number 80010204 1d09ffff Numeric sensor NumericSensorElementName going low lower critical has asserted Fan 3Aa Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has asserted May also be shown as 8001...

Страница 369: ...ically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0480 User Response 1 Reseat the failing fan n which is indicated by a lit LED near the fan connector on the system board 2 Replace the failing fan n fan number 80010204 1d0bffff Numeric sensor NumericSensorElementName going low lower critical has asserted Fan 3Ba Tach This message is for the...

Страница 370: ...sserted May also be shown as 800102041d0cffff or 0x800102041d0cffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0480 User Response 1 Reseat the failing fan n which is indicated by a lit LED near the fan connector on the system board 2 Replace the failing fan n fan number 80010701 0701ffff Numeric ...

Страница 371: ...ing within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace system board LowProfile Temp Raid Temp 80010701 0c01ffff Numeric sensor NumericSensorElementName going high upper non critical has asserted Ambient Temp This message is for the use case when an implementation has detected an...

Страница 372: ...tical sensor going high has asserted May also be shown as 800107011401ffff or 0x800107011401ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Temperature SNMP Trap ID 12 CIM Information Prefix PLAT ID 0490 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow front and rear of the server that the air baffle is...

Страница 373: ...s installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace system board 80010701 2d01ffff Numeric sensor NumericSensorElementName going high upper non critical has asserted PCH Temp This message is f...

Страница 374: ...when an implementation has detected an Upper Critical sensor going high has asserted May also be shown as 800109010701ffff or 0x800109010701ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0494 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow front...

Страница 375: ...is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace system board 80010901 1401ffff Numeric sensor NumericSensorElementName going ...

Страница 376: ...e is for the use case when an implementation has detected an Upper Critical sensor going high has asserted May also be shown as 800109011402ffff or 0x800109011402ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0494 User Response 1 Make sure that the fans are operating that there are no obstruction...

Страница 377: ...affle is in place and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace system board 80010902 0701ffff Numeric sensor NumericSensorElementName ...

Страница 378: ...701ffff or 0x80010b010701ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0498 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow front and rear of the server that the air baffle is in place and correctly installed and that the server cover is instal...

Страница 379: ...nstalled and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace system board 80010b01 1401ffff Numeric sensor NumericSensorElementName going high upper non recoverable has asserted CPU1 VR Temp This message ...

Страница 380: ...er Non recoverable sensor going high has asserted May also be shown as 80010b011402ffff or 0x80010b011402ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0498 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow front and rear of the server that the ai...

Страница 381: ...lled and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Server Features and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace system board 80030006 2101ffff Sensor SensorElementName has deasserted Sig Verify Fail This message is for t...

Страница 382: ...ategory System Other SNMP Trap ID CIM Information Prefix PLAT ID 0509 User Response No action information only 80050108 0a01ffff Sensor SensorElementName has indicated limit exceeded PS 1 CS This message is for the use case when an implementation has detected a Sensor limit was exceeded May also be shown as 800501080a01ffff or 0x800501080a01ffff Severity Info Serviceable No Automatically notify su...

Страница 383: ...ation Prefix PLAT ID 0512 User Response No action information only 8007010f 2201ffff Sensor SensorElementName has transitioned from normal to non critical state GPT Status This message is for the use case when an implementation has detected a Sensor transitioned to non critical from normal May also be shown as 8007010f2201ffff or 0x8007010f2201ffff Severity Warning Serviceable Yes Automatically no...

Страница 384: ...viceable Yes Automatically notify support No Alert Category Warning Other SNMP Trap ID 60 CIM Information Prefix PLAT ID 0520 User Response Complete the following step to solve PCI I O resource errors 1 Go to F1 Setup 2 System Settings 3 Device and I O ports 4 PCI 64 bit Resource and choose enable 80070114 2201ffff Sensor SensorElementName has transitioned from normal to non critical state TPM Phy...

Страница 385: ... shown as 800702010301ffff or 0x800702010301ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0522 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow front and rear of the server that the air baffles are in place and correctly installed and that the s...

Страница 386: ...lace and correctly installed and that the server cover is installed and completely closed 2 Check the ambient temperature You must be operating within the specifications see Features and specifications for more information 3 Make sure that the heat sink for microprocessor n is installed correctly 4 Trained technician only Replace microprocessor n n microprocessor number 80070202 0701ffff Sensor Se...

Страница 387: ...ult This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe May also be shown as 800702080a01ffff or 0x800702080a01ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0522 User Response 1 Make sure that there are no obstructions such as bundled...

Страница 388: ...y fan 2 Use the IBM Power Configurator utility to ensure current system power consumption is under limitation For more information and to download the utility go to http www 03 ibm com systems bladecenter resources powerconfig html 3 Replace power supply n n power supply number PS 2 OP Fault PS 2 Therm Fault 8007020f 2582ffff Sensor SensorElementName has transitioned to critical from a less severe...

Страница 389: ...Severity Error Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID CIM Information Prefix PLAT ID 0522 User Response 1 Update the server firmware see Recovering the server firmware 2 If the problem persists trained technician only replace the system board see Removing the system board and Installing the system board 80070219 0701ffff Sensor SensorElementName h...

Страница 390: ...cluster solution before you update the code 4 Unplug and restore AC power cord then perform step 1 and 2 again 5 If problems still occurred trained technician only replace the system board 8007021b 0301ffff Sensor SensorElementName has transitioned to critical from a less severe state CPU 1 QPILinkErr This message is for the use case when an implementation has detected a Sensor transitioned to cri...

Страница 391: ...viceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0522 User Response 1 Check for a server firmware update 2 Make sure that the installed microprocessors are compatible 3 Make sure the microprocessor 2 expansion board is installed correctly see Installing the microprocessor 2 expansion board 4 Trained technician only Replace mi...

Страница 392: ...s and specifications for more information 3 Make sure that the heat sink for microprocessor n 4 Trained technician only Replace microprocessor n n microprocessor number 80070301 0302ffff Sensor SensorElementName has transitioned to non recoverable from a less severe state CPU 2 OverTemp This message is for the use case when an implementation has detected a Sensor transitioned to non recoverable fr...

Страница 393: ...se If the specified sensor is PS n 12V OC Fault complete the following steps until the problem is solved 1 Use the IBM Power Configurator utility to determine current system power consumption For more information and to download the utility go to http www 03 ibm com systems bladecenter resources powerconfig html 2 Follow actions in Power Problems and Solving Power Problems If the specified sensor ...

Страница 394: ...ces powerconfig html 2 Follow actions in Power Problems and Solving Power Problems If the specified sensor is PS n 12V OV Fault complete the following steps until the problem is solved 1 Check power supply n LED 2 Remove the failing power supply 3 Trained technician only Replace the system board n power supply number If the specified sensor is PS n 12V UV Fault complete the following steps until t...

Страница 395: ...roblem persists trained technician only replace the system board see Removing the system board and Installing the system board 8008010f 2101ffff Device LogicalDeviceElementName has been added Phy Presence Jmp This message is for the use case when an implementation has detected a Device was inserted May also be shown as 8008010f2101ffff or 0x8008010f2101ffff Severity Info Serviceable No Automatical...

Страница 396: ...information only 800b0008 1301ffff Redundancy RedundancySetElementName has been restored Power Unit This message is for the use case when an implementation has detected Redundancy was Restored May also be shown as 800b00081301ffff or 0x800b00081301ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Redundant Power Supply SNMP Trap ID 10 CIM Information Prefix P...

Страница 397: ...Ds 800b010a 1e81ffff Redundancy Lost for RedundancySetElementName has asserted Cooling Zone 1 This message is for the use case when Redundancy Lost has asserted May also be shown as 800b010a1e81ffff or 0x800b010a1e81ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Fan Failure SNMP Trap ID 11 CIM Information Prefix PLAT ID 0802 User Response 1 Make sure th...

Страница 398: ...p ID 11 CIM Information Prefix PLAT ID 0802 User Response 1 Make sure that the connectors on fan n are not damaged 2 Make sure that the fan n connectors on the system board are not damaged 3 Make sure that the fans are correctly installed 4 Reseat the fans 5 Replace the fans n fan number 800b010c 2581ffff Redundancy Lost for RedundancySetElementName has asserted Backup Memory This message is for t...

Страница 399: ... Sufficient May also be shown as 800b030c2581ffff or 0x800b030c2581ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0806 User Response 1 Check the system event log for DIMM failure events uncorrectable or PFA and correct the failures 2 Re enable mirroring in the Setup utility 800b050a 1e81ffff Non red...

Страница 400: ...seat the fans 5 Replace the fans n fan number 800b050a 1e82ffff Non redundant Insufficient Resources for RedundancySetElementName has asserted Cooling Zone 2 This message is for the use case when a Redundancy Set has transitioned to Non redundant Insufficient Resources May also be shown as 800b050a1e82ffff or 0x800b050a1e82ffff Severity Error Serviceable Yes Automatically notify support No Alert C...

Страница 401: ...81ffff or 0x800b050c2581ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0810 User Response 1 Check the system event log for DIMM failure events uncorrectable or PFA and correct the failures 2 Re enable mirroring in the Setup utility 806f0007 0301ffff ProcessorElementName has Failed with IERR CPU 1 Thi...

Страница 402: ...r n n microprocessor number 6 Trained technician only Replace the system board 806f0007 0302ffff ProcessorElementName has Failed with IERR CPU 2 This message is for the use case when an implementation has detected a Processor Failed IERR Condition May also be shown as 806f00070302ffff or 0x806f00070302ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical CPU S...

Страница 403: ... a Power Supply has been added May also be shown as 806f00080a01ffff or 0x806f00080a01ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0084 User Response No action information only 806f0008 0a02ffff PowerSupplyElementName has been added to container PhysicalPackageElementName Power Supply 2 This message is for...

Страница 404: ...erviceable No Automatically notify support No Alert Category System Power Off SNMP Trap ID 23 CIM Information Prefix PLAT ID 0106 User Response No action information only 806f000d 0400ffff The Drive StorageVolumeElementName has been added Drive 0 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0400ffff or 0x806f000d0400ffff S...

Страница 405: ...y notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0402ffff The Drive StorageVolumeElementName has been added Drive 2 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0402ffff or 0x806f000d0402ffff Severity Info Servic...

Страница 406: ...lert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0404ffff The Drive StorageVolumeElementName has been added Drive 4 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0404ffff or 0x806f000d0404ffff Severity Info Serviceable No Automaticall...

Страница 407: ... Trap ID 5 CIM Information Prefix PLAT ID 0162 User Response No action information only 806f000d 0406ffff The Drive StorageVolumeElementName has been added Drive 6 This message is for the use case when an implementation has detected a Drive has been Added May also be shown as 806f000d0406ffff or 0x806f000d0406ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical...

Страница 408: ...mation Prefix PLAT ID 0162 User Response No action information only 806f000f 220101ff The System ComputerSystemElementName has detected no memory in the system ABR Status This message is for the use case when an implementation has detected that memory was detected in the system May also be shown as 806f000f220101ff or 0x806f000f220101ff Severity Error Serviceable Yes Automatically notify support N...

Страница 409: ...ategory Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0132 User Response 1 This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for the appropriate user response Firmware Error Sys Boot Status 806f000f 220103ff The System Comp...

Страница 410: ... or 0x806f000f220104ff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0795 User Response 1 This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Center for th...

Страница 411: ...re error no video device detected ABR Status This message is for the use case when an implementation has detected that System Firmware Error No video device detected has occurred May also be shown as 806f000f22010aff or 0x806f000f22010aff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0766 User Response 1 ...

Страница 412: ... the server firmware to the latest level see Updating the firmware Important Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 4 Remove components one at a time restarting the server each time to see if the problem goes away...

Страница 413: ...f000f2201ffff or 0x806f000f2201ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0184 User Response This is a UEFI detected event The UEFI diagnostic code for this event can be found in the logged IMM message text Please refer to the UEFI diagnostic code in the UEFI diagnostic code section of the Info Ce...

Страница 414: ...erSystemElementName No Op ROM Space This message is for the use case when an implementation has detected a Fault in a slot May also be shown as 806f00212201ffff or 0x806f00212201ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0330 User Response 1 Check the PCI LED 2 Reseat the affected adapters and ri...

Страница 415: ... PLAT ID 0330 User Response 1 Check the PCI LED 2 Reseat the affected adapters and riser card 3 Update the server firmware UEFI and IMM and adapter firmware Important Some cluster solutions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 4 Repla...

Страница 416: ...code is supported for the cluster solution before you update the code 4 Replace the affected adapters 5 Replace the riser card 6 Trained service technicians only Replace the system board 806f0023 2101ffff Watchdog Timer expired for WatchdogElementName IPMI Watchdog This message is for the use case when an implementation has detected a Watchdog Timer Expired May also be shown as 806f00232101ffff or...

Страница 417: ...ponse 1 Turn off the server and disconnect the power cords Reconnect the power cords and restart the server 2 If the problem remains trained technician only replace the system board 806f0107 0301ffff An Over Temperature Condition has been detected on ProcessorElementName CPU 1 This message is for the use case when an implementation has detected an Over Temperature Condition Detected for Processor ...

Страница 418: ...0302ffff or 0x806f01070302ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0036 User Response 1 Make sure that the fans are operating There are no obstructions to the airflow front and rear of the server the air baffles are in place and correctly installed and the server cover is installed and comp...

Страница 419: ...led Power Supply 2 This message is for the use case when an implementation has detected a Power Supply has failed May also be shown as 806f01080a02ffff or 0x806f01080a02ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0086 User Response 1 Reseat power supply n 2 If the power on LED is not lit and the po...

Страница 420: ...yElementName on Subsystem MemoryElementName DIMM 1 This message is for the use case when an implementation has detected a Memory uncorrectable error May also be shown as 806f010c2001ffff or 0x806f010c2001ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response Note Each time you install or ...

Страница 421: ...y Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Check the IBM support website for an applicable retain tip or firmware update that applies to thi...

Страница 422: ... DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 4 If the problem follows the DIMM replace the failing DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remov...

Страница 423: ...m occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 806f010c 2005ffff Unco...

Страница 424: ...d 7 Trained technician only Replace the affected microprocessor 806f010c 2006ffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 6 This message is for the use case when an implementation has detected a Memory uncorrectable error May also be shown as 806f010c2006ffff or 0x806f010c2006ffff Severity Error Serviceable Yes Automatically notify support Yes...

Страница 425: ...ll or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Manually re enable all affected DIMMs 3 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channe...

Страница 426: ...o a different memory channel or microprocessor 4 If the problem follows the DIMM replace the failing DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for an...

Страница 427: ...reign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 806f010c 200affff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 10...

Страница 428: ...Name DIMM 11 This message is for the use case when an implementation has detected a Memory uncorrectable error May also be shown as 806f010c200bffff or 0x806f010c200bffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0138 User Response Note Each time you install or remove a DIMM you must disconnect the ...

Страница 429: ...retain tip or firmware update that applies to this memory error 2 Manually re enable all affected DIMMs 3 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 4 If the problem follows the DIMM replace the failing DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM conn...

Страница 430: ...M 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affec...

Страница 431: ...own as 806f010d0401ffff or 0x806f010d0401ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system boar...

Страница 432: ... at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010d 0403ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 3 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be sh...

Страница 433: ... Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive wait 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the o...

Страница 434: ... to a detected fault Drive 6 This message is for the use case when an implementation has detected a Drive was Disabled due to fault May also be shown as 806f010d0406ffff or 0x806f010d0406ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0164 User Response 1 Run the hard disk drive diagnostic te...

Страница 435: ...it 1 minute or more before reinstalling the drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f010f 2201ffff The System ComputerSystemElementName encountered a firmware hang Fi...

Страница 436: ...message is for the use case when an implementation has detected a Bus Timeout May also be shown as 806f01130301ffff or 0x806f01130301ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0224 User Response 1 Trained technician only Reseat the microprocessor and then restart the server 2 Trained technician on...

Страница 437: ...x806f011b0701ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0266 User Response If the specified sensor is front USB connector reset the front USB cable on the system board If the specified sensor is front video connector reset the front video cable in the system board If the specified sensor is PwrPa...

Страница 438: ...370 User Response No action information only 806f0125 0b01ffff ManagedElementName detected as absent PCI Riser 1 This message is for the use case when an implementation has detected a Managed Element is Absent May also be shown as 806f01250b01ffff or 0x806f01250b01ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ...

Страница 439: ... Panel This message is for the use case when an implementation has detected a Managed Element is Absent May also be shown as 806f01250c01ffff or 0x806f01250c01ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0392 User Response Please ensure the PCI riser 1 has been installed correctly 806f0207 0301ffff Process...

Страница 440: ...rify that the latest level of code is supported for the cluster solution before you update the code 2 Run the DSA program 3 Reseat the adapter 4 Replace the adapter 5 Trained technician only Replace microprocessor n n microprocessor number 6 Trained technician only Replace the system board 806f0207 0302ffff ProcessorElementName has Failed with FRB1 BIST condition CPU 2 This message is for the use ...

Страница 441: ...s message is for the use case when an implementation has detected a Processor Failed FRB1 BIST condition May also be shown as 806f02072584ffff or 0x806f02072584ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0044 User Response 1 Update the latest level of system firmware and device drivers are installed...

Страница 442: ...ic test on drive n 2 Reseat the following components a Hard disk drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 0401ffff Failure Predicted on drive StorageVolumeElemen...

Страница 443: ...ion has detected an Array Failure is Predicted May also be shown as 806f020d0402ffff or 0x806f020d0402ffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive b Cable from the...

Страница 444: ...he following components one at a time in the order shown restarting the server each time a Hard disk drive b Cable from the system board to the backplane c Hard disk drive backplane n hard disk drive number 806f020d 0404ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 4 This message is for the use case when an implementation has detected an Array F...

Страница 445: ... Serviceable Yes Automatically notify support Yes Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0168 User Response 1 Run the hard disk drive diagnostic test on drive n 2 Reseat the following components a Hard disk drive b Cable from the system board to the backplane 3 Replace the following components one at a time in the order shown restarting the server ea...

Страница 446: ...rive backplane n hard disk drive number 806f020d 0407ffff Failure Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 7 This message is for the use case when an implementation has detected an Array Failure is Predicted May also be shown as 806f020d0407ffff or 0x806f020d0407ffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category System...

Страница 447: ...as 806f02232101ffff or 0x806f02232101ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0372 User Response No action information only 806f0308 0a01ffff PowerSupplyElementName has lost input Power Supply 1 This message is for the use case when an implementation has detected a Power Supply that has input that has ...

Страница 448: ...rity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0100 User Response 1 Reconnect the power cords 2 Check power supply n LED 3 See Power supply LEDs for more information n power supply number 806f030c 2001ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 1 This message is for the use ca...

Страница 449: ...e problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 806f030c 2002f...

Страница 450: ...system board 7 Trained technician only Replace the affected microprocessor 806f030c 2003ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 3 This message is for the use case when an implementation has detected a Memory Scrub failure May also be shown as 806f030c2003ffff or 0x806f030c2003ffff Severity Error Serviceable Yes Automatically notify support No Alert Cate...

Страница 451: ...r remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Manually re enable all affected DIMMs 3 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or...

Страница 452: ...t logs to a different memory channel or microprocessor 4 If the problem follows the DIMM replace the failing DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pin...

Страница 453: ...tains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 806f030c 2007ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 7 Thi...

Страница 454: ... DIMM 8 This message is for the use case when an implementation has detected a Memory Scrub failure May also be shown as 806f030c2008ffff or 0x806f030c2008ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response Note Each time you install or remove a DIMM you must disconnect the server from ...

Страница 455: ...retain tip or firmware update that applies to this memory error 2 Manually re enable all affected DIMMs 3 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 4 If the problem follows the DIMM replace the failing DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM conn...

Страница 456: ...lace the failing DIMM 5 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 6 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician on...

Страница 457: ...emove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 7 Trained technician only Replace the affected microprocessor 806f030c 200cffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 12 This message is for the use case when an implementation has detected a Memory Scrub failure May...

Страница 458: ...cally notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0136 User Response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Manually re enab...

Страница 459: ...e 1 Check the device driver 2 Reinstall the device driver 3 Update all device drivers to the latest level 4 Update the firmware UEFI and IMM 806f0323 2101ffff Power cycle of system ComputerSystemElementName initiated by watchdog WatchdogElementName IPMI Watchdog This message is for the use case when an implementation has detected a Power Cycle by Watchdog occurred May also be shown as 806f03232101...

Страница 460: ...ory uncorrectable error or memory logging limit reached follow the suggested actions for that error event and restart the server 3 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the Advanced Settin...

Страница 461: ...MM 3 This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c2003ffff or 0x806f040c2003ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a ...

Страница 462: ...ow the suggested actions for that error event and restart the server 3 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the Advanced Settings Utility ASU 806f040c 2005ffff PhysicalMemoryElementName D...

Страница 463: ...806f040c2006ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit reached follow the suggested actions for that error event and restart the server 3 ...

Страница 464: ...mory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the Advanced Settings Utility ASU 806f040c 2008ffff PhysicalMemoryElementName Disabled on Subsystem MemoryElementName DIMM 8 This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f04...

Страница 465: ...tify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was disabled because of a memory fault memory uncorrectable error or memory logging limit reached follow the suggested actions for that error event and restart the server 3 Check the IBM support website for an applicable retain tip or ...

Страница 466: ...moryElementName DIMM 11 This message is for the use case when an implementation has detected that Memory has been Disabled May also be shown as 806f040c200bffff or 0x806f040c200bffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0131 User Response 1 Make sure the DIMM is installed correctly 2 If the DIMM was dis...

Страница 467: ...e suggested actions for that error event and restart the server 3 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory event If no memory fault is recorded in the logs and no DIMM connector error LED is lit you can re enable the DIMM through the Setup utility or the Advanced Settings Utility ASU 806f040c 2581ffff PhysicalMemoryElementName Disabl...

Страница 468: ...s message is for the use case when an implementation has detected a PCI PERR May also be shown as 806f04132582ffff or 0x806f04132582ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0232 User Response 1 Check the PCI LED 2 Reseat the affected adapters and riser cards 3 Update the server firmware UEFI and...

Страница 469: ... other 2 Trained technician only Reseat microprocessor n 3 Trained technician only Replace microprocessor n n microprocessor number 806f0507 0302ffff ProcessorElementName has a Configuration Mismatch CPU 2 This message is for the use case when an implementation has detected a Processor Configuration Mismatch has occurred May also be shown as 806f05070302ffff or 0x806f05070302ffff Severity Error Se...

Страница 470: ...rt Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0062 User Response 1 Make sure that the installed microprocessors are compatible with each other 2 Trained technician only Reseat microprocessor n 3 Trained technician only Replace microprocessor n n microprocessor number One of The CPUs 806f050c 2001ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem ...

Страница 471: ...Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 6 Trained technician only Replace the affected microprocessor 806f050c 2002ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 2 This message is for the use case when an implementation has detected that the Me...

Страница 472: ...3ffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0144 User Response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Check the IBM support website for an applicable retain tip or firmware update that ...

Страница 473: ...e error LEDs on the system board or the event logs to a different memory channel or microprocessor 3 If the error still occurs on the same DIMM replace the affected DIMM 4 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 5 Trained technician only Remove the affecte...

Страница 474: ...s on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 5 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 6 Trained technician only Replace the affected microprocessor 806f050c 2006ffff Memory Logg...

Страница 475: ...it Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 7 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c2007ffff or 0x806f050c2007ffff Severity Warning Serviceable Yes Automatically notify support Yes Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 01...

Страница 476: ...e for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a different memory channel or microprocessor 3 If the error still occurs on the same DIMM replace the affected DIMM 4 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If...

Страница 477: ...cian only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 5 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins for any damaged pins If a damage is found replace the system board 6 Trained technician only Replace the affected microprocessor...

Страница 478: ... damaged pins If a damage is found replace the system board 6 Trained technician only Replace the affected microprocessor 806f050c 200bffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 11 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Reached May also be shown as 806f050c200bffff or 0x806...

Страница 479: ...Prefix PLAT ID 0144 User Response Note Each time you install or remove a DIMM you must disconnect the server from the power source then wait 10 seconds before restarting the server 1 Check the IBM support website for an applicable retain tip or firmware update that applies to this memory error 2 Swap the affected DIMMs as indicated by the error LEDs on the system board or the event logs to a diffe...

Страница 480: ...ferent memory channel or microprocessor 3 If the error still occurs on the same DIMM replace the affected DIMM 4 Trained technician only If the problem occurs on the same DIMM connector check the DIMM connector If the connector contains any foreign material or is damaged replace the system board 5 Trained technician only Remove the affected microprocessor and check the microprocessor socket pins f...

Страница 481: ...This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0401ffff or 0x806f050d0401ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are a...

Страница 482: ... firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f050d 0403ffff Array ComputerSystemElementName is in critical condition Drive 3 This message is for the use case when an implementation has detected that a...

Страница 483: ... Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID ada...

Страница 484: ...indicated by a lit status LED 806f050d 0406ffff Array ComputerSystemElementName is in critical condition Drive 6 This message is for the use case when an implementation has detected that an Array is Critical May also be shown as 806f050d0406ffff or 0x806f050d0406ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Informatio...

Страница 485: ...D 5 CIM Information Prefix PLAT ID 0174 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Check backplane cable connection 5 Replace the RAID adapter 6 Replace the hard disk drive that is indicated by a lit status LED 806f0513 2582ffff A PCI SERR has occurred ...

Страница 486: ...e http www ibm com systems info x86servers serverproven compat us 5 Remove both adapters 6 Replace the PCIe adapters 7 Replace the riser card 806f052b 2201ffff Invalid or Unsupported firmware or software was detected on system ComputerSystemElementName IMM2 FW Failover This message is for the use case when an implementation has detected an Invalid Unsupported Firmware Software Version May also be ...

Страница 487: ...6070301ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0816 User Response 1 Update the latest level of system firmware and device drivers are installed for all adapters and standard devices such as UEFI IMM Ethernet and SAS Important Some cluster solutions require specific code levels or coordinated code...

Страница 488: ...hat the latest level of code is supported for the cluster solution before you update the code 2 Run the DSA program 3 Reseat the adapter 4 Replace the adapter 5 Trained technician only Replace microprocessor n n microprocessor number 6 Trained technician only Replace the system board 806f0607 2584ffff An SM BIOS Uncorrectable CPU complex error for ProcessorElementName has asserted All CPUs This me...

Страница 489: ...06f0608 1301ffff PowerSupplyElementName has a Configuration Mismatch PS Configuration This message is for the use case when an implementation has detected a Power Supply with a Configuration Error May also be shown as 806f06081301ffff or 0x806f06081301ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0104...

Страница 490: ...tatus LED 806f060d 0401ffff Array ComputerSystemElementName has failed Drive 1 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0401ffff or 0x806f060d0401ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 ...

Страница 491: ...ser Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f060d 0403ffff Array ComputerSystemElementName has failed Drive 3 This message is for the use case when an implemen...

Страница 492: ... 0x806f060d0404ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace ...

Страница 493: ... a lit status LED 806f060d 0406ffff Array ComputerSystemElementName has failed Drive 6 This message is for the use case when an implementation has detected that an Array Failed May also be shown as 806f060d0406ffff or 0x806f060d0406ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0176 User Res...

Страница 494: ...6 User Response 1 Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level 2 Make sure that the SAS cable is connected correctly 3 Replace the SAS cable 4 Replace the RAID adapter 5 Replace the hard disk drive that is indicated by a lit status LED 806f070c 2001ffff Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 1 This mess...

Страница 495: ...r 0x806f070c2002ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed and following the memory population chart in the system publication 806f070c 2003ffff Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 3 This messa...

Страница 496: ... shown as 806f070c2004ffff or 0x806f070c2004ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed and following the memory population chart in the system publication 806f070c 2005ffff Configuration Error for PhysicalMemoryElementName on Subsystem MemoryE...

Страница 497: ...May also be shown as 806f070c2006ffff or 0x806f070c2006ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed and following the memory population chart in the system publication 806f070c 2007ffff Configuration Error for PhysicalMemoryElementName on Subsys...

Страница 498: ...MM configuration error has been corrected May also be shown as 806f070c2008ffff or 0x806f070c2008ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed and following the memory population chart in the system publication 806f070c 2009ffff Configuration Err...

Страница 499: ...IMM 10 This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected May also be shown as 806f070c200affff or 0x806f070c200affff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0126 User Response Make sure that DIMMs are installed and following th...

Страница 500: ...system publication 806f070c 200cffff Configuration Error for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 12 This message is for the use case when an implementation has detected a Memory DIMM configuration error has been corrected May also be shown as 806f070c200cffff or 0x806f070c200cffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Memor...

Страница 501: ...x PLAT ID 0126 User Response Make sure that DIMMs are installed and following the memory population chart in the system publication One of the DIMMs 806f070d 0400ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 0 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0400ffff or 0x806f070d04...

Страница 502: ...ry System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0402ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 2 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0402ffff or 0x806f070d0402ffff Severity Info Serviceable No Automat...

Страница 503: ... Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0404ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 4 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0404ffff or 0x806f070d0404ffff Severity Info Serviceab...

Страница 504: ...ally notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f070d 0406ffff Rebuild in progress for Array in system ComputerSystemElementName Drive 6 This message is for the use case when an implementation has detected that an Array Rebuild is in Progress May also be shown as 806f070d0406ffff or 0x806f070d0406ffff S...

Страница 505: ...port No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0178 User Response No action information only 806f072b 2201ffff A successful software or firmware change was detected on system ComputerSystemElementName Bkup Auto Update This message is for the use case when an implementation has detected a Successful Software or Firmware Change May also be shown as 806f072b2201ffff o...

Страница 506: ...tomatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0061 User Response No action information only 806f0807 0302ffff ProcessorElementName has been Disabled CPU 2 This message is for the use case when an implementation has detected a Processor has been Disabled May also be shown as 806f08070302ffff or 0x806f08070302ffff Severity Info Serviceable No A...

Страница 507: ...r SNMP Trap ID CIM Information Prefix PLAT ID 0061 User Response No action information only One of The CPUs 806f0813 2581ffff A Uncorrectable Bus Error has occurred on system ComputerSystemElementName DIMMs This message is for the use case when an implementation has detected a Bus Uncorrectable Error May also be shown as 806f08132581ffff or 0x806f08132581ffff Severity Error Serviceable Yes Automat...

Страница 508: ...ed a Bus Uncorrectable Error May also be shown as 806f08132582ffff or 0x806f08132582ffff Severity Error Serviceable Yes Automatically notify support Yes Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0240 User Response 1 Check the PCI LED 2 Reseat the affected adapter and riser card 3 Update the server firmware UEFI and IMM and adapter firmware Important Some cluster ...

Страница 509: ...ions require specific code levels or coordinated code updates If the device is part of a cluster solution verify that the latest level of code is supported for the cluster solution before you update the code 4 Make sure that the two microprocessors are matching 5 Trained technician only Replace the system board 806f0823 2101ffff Watchdog Timer interrupt occurred for WatchdogElementName IPMI Watchd...

Страница 510: ...notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2002ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 2 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806...

Страница 511: ...090c2003ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2004ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 4 This message is for the use case when an implementation has...

Страница 512: ...y also be shown as 806f090c2005ffff or 0x806f090c2005ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2006ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 6 This message i...

Страница 513: ... MemoryElementName Throttled DIMM 7 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c2007ffff or 0x806f090c2007ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Re...

Страница 514: ...Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 2009ffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 9 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c2009ffff or 0x806f090c2009ffff Severity Warning Serviceable Yes Automatic...

Страница 515: ...lert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f090c 200bffff PhysicalMemoryElementName on Subsystem MemoryElementName Throttled DIMM 11 This message is for the use case when an implementation has detected Memory has been Throttled May also be shown as 806f090c200bffff or 0...

Страница 516: ...Serviceable Yes Automatically notify support No Alert Category System Other SNMP Trap ID 22 CIM Information Prefix PLAT ID 0142 User Response 1 Reseat the DIMM and then restart the server 2 Replace DIMM n n DIMM number 806f0a07 0301ffff ProcessorElementName is operating in a Degraded State CPU 1 This message is for the use case when an implementation has detected a Processor is running in the Degr...

Страница 517: ...is for the use case when an implementation has detected a Processor is running in the Degraded state May also be shown as 806f0a070302ffff or 0x806f0a070302ffff Severity Warning Serviceable Yes Automatically notify support No Alert Category Warning CPU SNMP Trap ID 42 CIM Information Prefix PLAT ID 0038 User Response 1 Make sure that the fans are operating that there are no obstructions to the air...

Страница 518: ...e airflow that the air baffles are in place and correctly installed and that the server cover is installed and completely closed 2 Make sure that ambient temperature is within the specifications 3 If a fan has failed complete the action for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 2002ffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem Me...

Страница 519: ...emperature Condition for Memory that has been Detected May also be shown as 806f0a0c2003ffff or 0x806f0a0c2003ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow that the air baffles are in place a...

Страница 520: ... the server cover is installed and completely closed 2 Make sure that ambient temperature is within the specifications 3 If a fan has failed complete the action for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 2005ffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 5 This message is for the use case when an implementati...

Страница 521: ...s 806f0a0c2006ffff or 0x806f0a0c2006ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow that the air baffles are in place and correctly installed and that the server cover is installed and complete...

Страница 522: ...ture is within the specifications 3 If a fan has failed complete the action for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 2008ffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 8 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May a...

Страница 523: ... Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow that the air baffles are in place and correctly installed and that the server cover is installed and completely closed 2 Make sure that ambient temperature is...

Страница 524: ...f a fan has failed complete the action for a fan failure 4 Replace DIMM n n DIMM number 806f0a0c 200bffff An Over Temperature Condition has been detected on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 11 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected May also be shown as 806f0a0c200bffff or ...

Страница 525: ...or 0x806f0a0c200cffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0146 User Response 1 Make sure that the fans are operating that there are no obstructions to the airflow that the air baffles are in place and correctly installed and that the server cover is installed and completely closed 2 Make su...

Страница 526: ...l Error May also be shown as 806f0a130302ffff or 0x806f0a130302ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0244 User Response 1 Trained technician only Reseat the microprocessor and then restart the server 2 Trained technician only Replace microprocessor n n microprocessor number 81010002 0701ffff ...

Страница 527: ...sage is for the use case when an implementation has detected a Lower Critical sensor going low has deasserted May also be shown as 810102020701ffff or 0x810102020701ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Voltage SNMP Trap ID 1 CIM Information Prefix PLAT ID 0481 User Response No action information only SysBrd 12V SysBrd 3 3V SysBrd 5V 81010204 1d0...

Страница 528: ...information only 81010204 1d02ffff Numeric sensor NumericSensorElementName going low lower critical has deasserted Fan 1Ab Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has deasserted May also be shown as 810102041d02ffff or 0x810102041d02ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Fan Failu...

Страница 529: ...mation Prefix PLAT ID 0481 User Response No action information only 81010204 1d04ffff Numeric sensor NumericSensorElementName going low lower critical has deasserted Fan 1Bb Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has deasserted May also be shown as 810102041d04ffff or 0x810102041d04ffff Severity Info Serviceable No Automatically ...

Страница 530: ...Information Prefix PLAT ID 0481 User Response No action information only 81010204 1d06ffff Numeric sensor NumericSensorElementName going low lower critical has deasserted Fan 2Ab Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has deasserted May also be shown as 810102041d06ffff or 0x810102041d06ffff Severity Info Serviceable No Automatic...

Страница 531: ...mation Prefix PLAT ID 0481 User Response No action information only 81010204 1d08ffff Numeric sensor NumericSensorElementName going low lower critical has deasserted Fan 2Bb Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has deasserted May also be shown as 810102041d08ffff or 0x810102041d08ffff Severity Info Serviceable No Automatically ...

Страница 532: ...Information Prefix PLAT ID 0481 User Response No action information only 81010204 1d0affff Numeric sensor NumericSensorElementName going low lower critical has deasserted Fan 3Ab Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has deasserted May also be shown as 810102041d0affff or 0x810102041d0affff Severity Info Serviceable No Automatic...

Страница 533: ...mation Prefix PLAT ID 0481 User Response No action information only 81010204 1d0cffff Numeric sensor NumericSensorElementName going low lower critical has deasserted Fan 3Bb Tach This message is for the use case when an implementation has detected a Lower Critical sensor going low has deasserted May also be shown as 810102041d0cffff or 0x810102041d0cffff Severity Info Serviceable No Automatically ...

Страница 534: ...fix PLAT ID 0491 User Response No action information only LowProfile Temp Raid Temp 81010701 0c01ffff Numeric sensor NumericSensorElementName going high upper non critical has deasserted Ambient Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has deasserted May also be shown as 810107010c01ffff or 0x810107010c01ffff Severity Info Se...

Страница 535: ...mation Prefix PLAT ID 0491 User Response No action information only 81010701 1402ffff Numeric sensor NumericSensorElementName going high upper non critical has deasserted CPU2 VR Temp This message is for the use case when an implementation has detected an Upper Non critical sensor going high has deasserted May also be shown as 810107011402ffff or 0x810107011402ffff Severity Info Serviceable No Aut...

Страница 536: ...n Prefix PLAT ID 0491 User Response No action information only 81010901 0701ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted FHHL Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has deasserted May also be shown as 810109010701ffff or 0x810109010701ffff Severity Info Serviceable No Automatically notif...

Страница 537: ...mation Prefix PLAT ID 0495 User Response No action information only 81010901 1401ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted CPU1 VR Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has deasserted May also be shown as 810109011401ffff or 0x810109011401ffff Severity Info Serviceable No Automatical...

Страница 538: ...M Information Prefix PLAT ID 0495 User Response No action information only 81010901 2d01ffff Numeric sensor NumericSensorElementName going high upper critical has deasserted PCH Temp This message is for the use case when an implementation has detected an Upper Critical sensor going high has deasserted May also be shown as 810109012d01ffff or 0x810109012d01ffff Severity Info Serviceable No Automati...

Страница 539: ...Response No action information only SysBrd 3 3V SysBrd 5V 81010b01 0701ffff Numeric sensor NumericSensorElementName going high upper non recoverable has deasserted FHHL Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has deasserted May also be shown as 81010b010701ffff or 0x81010b010701ffff Severity Info Serviceable No Automatica...

Страница 540: ...Information Prefix PLAT ID 0499 User Response No action information only 81010b01 1401ffff Numeric sensor NumericSensorElementName going high upper non recoverable has deasserted CPU1 VR Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has deasserted May also be shown as 81010b011401ffff or 0x81010b011401ffff Severity Info Service...

Страница 541: ...ormation Prefix PLAT ID 0499 User Response No action information only 81010b01 2d01ffff Numeric sensor NumericSensorElementName going high upper non recoverable has deasserted PCH Temp This message is for the use case when an implementation has detected an Upper Non recoverable sensor going high has deasserted May also be shown as 81010b012d01ffff or 0x81010b012d01ffff Severity Info Serviceable No...

Страница 542: ... No action information only 81030012 2301ffff Sensor SensorElementName has asserted OS RealTime Mod This message is for the use case when an implementation has detected a Sensor has asserted May also be shown as 810300122301ffff or 0x810300122301ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0508 User Respon...

Страница 543: ...ction information only 81050108 0a02ffff Sensor SensorElementName has indicated limit no longer exceeded PS 2 CS This message is for the use case when an implementation has detected a Sensor limit is no longer exceeded May also be shown as 810501080a02ffff or 0x810501080a02ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Pre...

Страница 544: ... Prefix PLAT ID 0521 User Response No action information only TXT ACM Module 8107010f 2582ffff Sensor SensorElementName has deasserted the transition from normal to non critical state No PCI I O Space This message is for the use case when an implementation has detected that a Sensor has deasserted a transition to non critical from normal May also be shown as 8107010f2582ffff or 0x8107010f2582ffff ...

Страница 545: ...mation Prefix PLAT ID 0523 User Response No action information only 81070201 0302ffff Sensor SensorElementName has transitioned to a less severe state from critical CPU 2 OverTemp This message is for the use case when an implementation has detected a Sensor transition to less severe from critical May also be shown as 810702010302ffff or 0x810702010302ffff Severity Info Serviceable No Automatically...

Страница 546: ...efix PLAT ID 0523 User Response No action information only 81070208 0a01ffff Sensor SensorElementName has transitioned to a less severe state from critical PS 1 Fan Fault This message is for the use case when an implementation has detected a Sensor transition to less severe from critical May also be shown as 810702080a01ffff or 0x810702080a01ffff Severity Info Serviceable No Automatically notify s...

Страница 547: ...T ID 0523 User Response No action information only PS 2 OP Fault PS 2 Therm Fault 8107020f 2582ffff Sensor SensorElementName has transitioned to a less severe state from critical No PCI I O Space This message is for the use case when an implementation has detected a Sensor transition to less severe from critical May also be shown as 8107020f2582ffff or 0x8107020f2582ffff Severity Info Serviceable ...

Страница 548: ...formation Prefix PLAT ID 0523 User Response No action information only 81070219 0701ffff Sensor SensorElementName has transitioned to a less severe state from critical SysBrd Fault This message is for the use case when an implementation has detected a Sensor transition to less severe from critical May also be shown as 810702190701ffff or 0x810702190701ffff Severity Info Serviceable No Automaticall...

Страница 549: ...mation Prefix PLAT ID 0523 User Response No action information only 8107021b 0302ffff Sensor SensorElementName has transitioned to a less severe state from critical CPU 2 QPILinkErr This message is for the use case when an implementation has detected a Sensor transition to less severe from critical May also be shown as 8107021b0302ffff or 0x8107021b0302ffff Severity Info Serviceable No Automatical...

Страница 550: ...Information Prefix PLAT ID 0525 User Response No action information only 81070301 0302ffff Sensor SensorElementName has deasserted the transition to non recoverable from a less severe state CPU 2 OverTemp This message is for the use case when an implementation has detected that the Sensor transition to non recoverable from less severe has deasserted May also be shown as 810703010302ffff or 0x81070...

Страница 551: ... action information only PS 1 OV Fault PS 1 UV Fault PS 1 VCO Fault 81070608 0a02ffff Sensor SensorElementName has deasserted the transition to non recoverable PS 2 OC Fault This message is for the use case when an implementation has detected that the Sensor transition to non recoverable has deasserted May also be shown as 810706080a02ffff or 0x810706080a02ffff Severity Info Serviceable No Automat...

Страница 552: ...Information Prefix PLAT ID 0803 User Response No action information only 810b010a 1e82ffff Redundancy Lost for RedundancySetElementName has deasserted Cooling Zone 2 This message is for the use case when Redundacy Lost has deasserted May also be shown as 810b010a1e82ffff or 0x810b010a1e82ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Fan Failure SNMP Trap...

Страница 553: ...formation only 810b030c 2581ffff Non redundant Sufficient Resources from Redundancy Degraded or Fully Redundant for RedundancySetElementName has deasserted Backup Memory This message is for the use case when a Redundancy Set has transitioned from Non redundant Sufficient Resources May also be shown as 810b030c2581ffff or 0x810b030c2581ffff Severity Info Serviceable No Automatically notify support ...

Страница 554: ...Information Prefix PLAT ID 0811 User Response No action information only 810b050a 1e82ffff Non redundant Insufficient Resources for RedundancySetElementName has deasserted Cooling Zone 2 This message is for the use case when a Redundancy Set has transitioned from Non redundant Insufficient Resources May also be shown as 810b050a1e82ffff or 0x810b050a1e82ffff Severity Info Serviceable No Automatica...

Страница 555: ...ry SNMP Trap ID 41 CIM Information Prefix PLAT ID 0811 User Response No action information only 816f0007 0301ffff ProcessorElementName has Recovered from IERR CPU 1 This message is for the use case when an implementation has detected a Processor Recovered IERR Condition May also be shown as 816f00070301ffff or 0x816f00070301ffff Severity Info Serviceable No Automatically notify support No Alert Ca...

Страница 556: ...PLAT ID 0043 User Response No action information only 816f0008 0a01ffff PowerSupplyElementName has been removed from container PhysicalPackageElementName Power Supply 1 This message is for the use case when an implementation has detected a Power Supply has been removed May also be shown as 816f00080a01ffff or 0x816f00080a01ffff Severity Info Serviceable No Automatically notify support No Alert Cat...

Страница 557: ... Trap ID CIM Information Prefix PLAT ID 0085 User Response No action information only 816f0009 1301ffff PowerSupplyElementName has been turned on Host Power This message is for the use case when an implementation has detected a Power Unit that has been Enabled May also be shown as 816f00091301ffff or 0x816f00091301ffff Severity Info Serviceable No Automatically notify support No Alert Category Sys...

Страница 558: ...ard disk drive number Wait 1 minute or more before reinstalling the drive 2 Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level 3 Check the SAS cable 4 Replace the hard disk drive 816f000d 0401ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 1 This message is for the use case when an implementation h...

Страница 559: ... 816f000d0402ffff or 0x816f000d0402ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Make sure that the disk firmware and RAID controller and backplane firmware are at the...

Страница 560: ...d backplane firmware are at the latest level 3 Check the SAS cable 4 Replace the hard disk drive 816f000d 0404ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 4 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0404ffff or 0x816f000d0404ffff Severity Error Serviceable Yes Aut...

Страница 561: ...eable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0163 User Response 1 Reseat hard disk drive n n hard disk drive number Wait 1 minute or more before reinstalling the drive 2 Make sure that the disk firmware and RAID controller and backplane firmware are at the latest level 3 Check the SAS cable 4 Replace the hard disk d...

Страница 562: ...isk drive 816f000d 0407ffff The Drive StorageVolumeElementName has been removed from unit PhysicalPackageElementName Drive 7 This message is for the use case when an implementation has detected a Drive has been Removed May also be shown as 816f000d0407ffff or 0x816f000d0407ffff Severity Error Serviceable Yes Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM...

Страница 563: ... Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0185 User Response No action information only Firmware Error Sys Boot Status 816f0013 1701ffff System ComputerSystemElementName has recovered from a diagnostic interrupt NMI State This message is for the use case when an implementation has detected a recovery from a Front Panel NMI Diagnos...

Страница 564: ...omatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0331 User Response No action information only 816f0021 2582ffff Fault condition removed on slot PhysicalConnectorElementName on system ComputerSystemElementName All PCI Error This message is for the use case when an implementation has detected a Fault condition in a slot has been removed May a...

Страница 565: ...tically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0331 User Response No action information only PCI 2 PCI 3 816f0028 2101ffff Sensor SensorElementName has returned to normal on management system ComputerSystemElementName TPM Cmd Failures This message is for the use case when an implementation has detected a Sensor returned from degraded unavaila...

Страница 566: ...Serviceable No Automatically notify support No Alert Category Critical Temperature SNMP Trap ID 0 CIM Information Prefix PLAT ID 0037 User Response No action information only 816f0107 0302ffff An Over Temperature Condition has been removed on ProcessorElementName CPU 2 This message is for the use case when an implementation has detected a Over Temperature Condition has been Removed for Processor M...

Страница 567: ... Serviceable No Automatically notify support No Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0087 User Response No action information only 816f0108 0a02ffff PowerSupplyElementName has returned to OK status Power Supply 2 This message is for the use case when an implementation has detected a Power Supply return to normal operational status May also be shown as 816f010...

Страница 568: ...o Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2002ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 2 This message is for the use case when an implementation has detected a Memory uncorrectable error recov...

Страница 569: ...everity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2004ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 4 This message is for the use case when an implementation has detected a Memory uncorrectable ...

Страница 570: ...010c2005ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2006ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 6 This message is for the use case when an implementation has detected a Memory ...

Страница 571: ...f or 0x816f010c2007ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 2008ffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 8 This message is for the use case when an implementation has detecte...

Страница 572: ...n as 816f010c2009ffff or 0x816f010c2009ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 200affff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 10 This message is for the use case when an imple...

Страница 573: ...shown as 816f010c200bffff or 0x816f010c200bffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only 816f010c 200cffff Uncorrectable error recovery detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 12 This message is for the use case when an i...

Страница 574: ...e error recovery May also be shown as 816f010c2581ffff or 0x816f010c2581ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0139 User Response No action information only One of the DIMMs 816f010d 0400ffff The Drive StorageVolumeElementName has been enabled Drive 0 This message is for the use case when an im...

Страница 575: ...fff or 0x816f010d0401ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0402ffff The Drive StorageVolumeElementName has been enabled Drive 2 This message is for the use case when an implementation has detected a Drive was Enabled May also be sh...

Страница 576: ...ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0404ffff The Drive StorageVolumeElementName has been enabled Drive 4 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d0404ff...

Страница 577: ...o Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010d 0406ffff The Drive StorageVolumeElementName has been enabled Drive 6 This message is for the use case when an implementation has detected a Drive was Enabled May also be shown as 816f010d0406ffff or 0x816f010d0406ffff Severit...

Страница 578: ...t No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0167 User Response No action information only 816f010f 2201ffff The System ComputerSystemElementName has recovered from a firmware hang Firmware Error This message is for the use case when an implementation has recovered from a System Firmware Hang May also be shown as 816f010f2201ffff or 0x816f010f2201ffff ...

Страница 579: ... only Replace microprocessor n see Removing a microprocessor and heat sink and Replacing a microprocessor and heat sink 2 If the problem persists and there is no other CPU with the same error indication replace the system board 3 Trained technician only Replace the system board see Removing the system board and Replacing the system board n microprocessor number 816f0113 0302ffff System ComputerSys...

Страница 580: ...umber 816f011b 0701ffff The connector PhysicalConnectorElementName configuration error has been repaired Front USB This message is for the use case when an implementation has detected an Interconnect Configuration was Repaired May also be shown as 816f011b0701ffff or 0x816f011b0701ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM In...

Страница 581: ...cted a Managed Element is now Present May also be shown as 816f01250b02ffff or 0x816f01250b02ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0390 User Response No action information only 816f0125 0c01ffff ManagedElementName detected as present Front Panel This message is for the use case when an implementatio...

Страница 582: ... condition May also be shown as 816f02070301ffff or 0x816f02070301ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0045 User Response No action information only 816f0207 0302ffff ProcessorElementName has Recovered from FRB1 BIST condition CPU 2 This message is for the use case when an implementation has det...

Страница 583: ...as 816f02072584ffff or 0x816f02072584ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0045 User Response No action information only One of The CPUs 816f020d 0400ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 0 This message is for the use case whe...

Страница 584: ...r Predicted May also be shown as 816f020d0401ffff or 0x816f020d0401ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0402ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 2 This messa...

Страница 585: ...edicted May also be shown as 816f020d0403ffff or 0x816f020d0403ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0404ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 4 This message i...

Страница 586: ...r Predicted May also be shown as 816f020d0405ffff or 0x816f020d0405ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f020d 0406ffff Failure no longer Predicted on drive StorageVolumeElementName for array ComputerSystemElementName Drive 6 This messa...

Страница 587: ...ger Predicted May also be shown as 816f020d0407ffff or 0x816f020d0407ffff Severity Info Serviceable No Automatically notify support No Alert Category System Predicted Failure SNMP Trap ID 27 CIM Information Prefix PLAT ID 0169 User Response No action information only 816f0308 0a01ffff PowerSupplyElementName has returned to a Normal Input State Power Supply 1 This message is for the use case when a...

Страница 588: ...rned to normal May also be shown as 816f03080a02ffff or 0x816f03080a02ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0099 User Response No action information only 816f030c 2001ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 1 This message is for the use case...

Страница 589: ...ry May also be shown as 816f030c2002ffff or 0x816f030c2002ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2003ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 3 This message is for the use case when ...

Страница 590: ... May also be shown as 816f030c2004ffff or 0x816f030c2004ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2005ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 5 This message is for the use case when an...

Страница 591: ...shown as 816f030c2006ffff or 0x816f030c2006ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2007ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 7 This message is for the use case when an implementati...

Страница 592: ...wn as 816f030c2008ffff or 0x816f030c2008ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2009ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 9 This message is for the use case when an implementation ...

Страница 593: ...f or 0x816f030c200affff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 200bffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered DIMM 11 This message is for the use case when an implementation has detected a Memor...

Страница 594: ...30c200cffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Memory SNMP Trap ID 41 CIM Information Prefix PLAT ID 0137 User Response No action information only 816f030c 2581ffff Scrub Failure for PhysicalMemoryElementName on Subsystem MemoryElementName has recovered All DIMMS This message is for the use case when an implementation has detected a Memory Scrub fa...

Страница 595: ...0x816f03131701ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0230 User Response No action information only 816f040c 2001ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 1 This message is for the use case when an implementation has detected that Memory has been Enabled May also ...

Страница 596: ...fff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2003ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 3 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c...

Страница 597: ...erviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2005ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 5 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2005ffff or 0x816f0...

Страница 598: ...le No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2007ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 7 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2007ffff or 0x816f040c2007f...

Страница 599: ...atically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2009ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 9 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2009ffff or 0x816f040c2009ffff Severit...

Страница 600: ...ally notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 200bffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName DIMM 11 This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c200bffff or 0x816f040c200bffff Severity I...

Страница 601: ...Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0130 User Response No action information only 816f040c 2581ffff PhysicalMemoryElementName Enabled on Subsystem MemoryElementName All DIMMS This message is for the use case when an implementation has detected that Memory has been Enabled May also be shown as 816f040c2581ffff or 0x816f040c2581ffff Severity Info Serviceable No Au...

Страница 602: ...egory Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0233 User Response No action information only 816f0507 0301ffff ProcessorElementName has Recovered from a Configuration Mismatch CPU 1 This message is for the use case when an implementation has Recovered from a Processor Configuration Mismatch May also be shown as 816f05070301ffff or 0x816f05070301ffff Severity Info Serviceable N...

Страница 603: ...t Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0063 User Response No action information only 816f0507 2584ffff ProcessorElementName has Recovered from a Configuration Mismatch All CPUs This message is for the use case when an implementation has Recovered from a Processor Configuration Mismatch May also be shown as 816f05072584ffff or 0x816f05072584ffff Severity Info Service...

Страница 604: ...tically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response No action information only 816f050c 2002ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 2 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as...

Страница 605: ...ally notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response No action information only 816f050c 2004ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 4 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also be shown as 81...

Страница 606: ... No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response No action information only 816f050c 2006ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 6 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed May also b...

Страница 607: ...rviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response No action information only 816f050c 2008ffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 8 This message is for the use case when an implementation has detected that the Memory Logging Limit has been Removed M...

Страница 608: ...ff Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response No action information only 816f050c 200affff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 10 This message is for the use case when an implementation has detected that the Memory Logging Limi...

Страница 609: ...00bffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response No action information only 816f050c 200cffff Memory Logging Limit Removed for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 12 This message is for the use case when an implementation has detected that the Memory Logging...

Страница 610: ...1ffff or 0x816f050c2581ffff Severity Info Serviceable No Automatically notify support No Alert Category Warning Memory SNMP Trap ID 43 CIM Information Prefix PLAT ID 0145 User Response No action information only One of the DIMMs 816f050d 0400ffff Critical Array ComputerSystemElementName has deasserted Drive 0 This message is for the use case when an implementation has detected that an Critiacal Ar...

Страница 611: ...401ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Response No action information only 816f050d 0402ffff Critical Array ComputerSystemElementName has deasserted Drive 2 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also ...

Страница 612: ...fff Severity Info Serviceable No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Response No action information only 816f050d 0404ffff Critical Array ComputerSystemElementName has deasserted Drive 4 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be s...

Страница 613: ...able No Automatically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Response No action information only 816f050d 0406ffff Critical Array ComputerSystemElementName has deasserted Drive 6 This message is for the use case when an implementation has detected that an Critiacal Array has deasserted May also be shown as 816f050d0406ffff ...

Страница 614: ...ically notify support No Alert Category Critical Hard Disk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0175 User Response No action information only 816f0607 0301ffff An SM BIOS Uncorrectable CPU complex error for ProcessorElementName has deasserted CPU 1 This message is for the use case when an SM BIOS Uncorrectable CPU complex error has deasserted May also be shown as 816f06070301ffff or...

Страница 615: ...cally notify support No Alert Category Critical CPU SNMP Trap ID 40 CIM Information Prefix PLAT ID 0817 User Response No action information only 816f0607 2584ffff An SM BIOS Uncorrectable CPU complex error for ProcessorElementName has deasserted All CPUs This message is for the use case when an SM BIOS Uncorrectable CPU complex error has deasserted May also be shown as 816f06072584ffff or 0x816f06...

Страница 616: ...No Alert Category Critical Power SNMP Trap ID 4 CIM Information Prefix PLAT ID 0105 User Response No action information only 816f060d 0400ffff Array in system ComputerSystemElementName has been restored Drive 0 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0400ffff or 0x816f060d0400ffff Severity Info Servicea...

Страница 617: ...isk drive SNMP Trap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0402ffff Array in system ComputerSystemElementName has been restored Drive 2 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0402ffff or 0x816f060d0402ffff Severity Info Serviceable No Automatically no...

Страница 618: ...rap ID 5 CIM Information Prefix PLAT ID 0177 User Response No action information only 816f060d 0404ffff Array in system ComputerSystemElementName has been restored Drive 4 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0404ffff or 0x816f060d0404ffff Severity Info Serviceable No Automatically notify support No ...

Страница 619: ...mation Prefix PLAT ID 0177 User Response No action information only 816f060d 0406ffff Array in system ComputerSystemElementName has been restored Drive 6 This message is for the use case when an implementation has detected that a Failed Array has been Restored May also be shown as 816f060d0406ffff or 0x816f060d0406ffff Severity Info Serviceable No Automatically notify support No Alert Category Cri...

Страница 620: ...PLAT ID 0177 User Response No action information only 816f070c 2001ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 1 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2001ffff or 0x816f070c2001ffff Severity Info Serviceable No Automatically noti...

Страница 621: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 2003ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 3 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2003ffff or 0x816f070c2003ffff Severity Info Serviceable No Auto...

Страница 622: ...Information Prefix PLAT ID 0127 User Response No action information only 816f070c 2005ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 5 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2005ffff or 0x816f070c2005ffff Severity Info Serviceable No...

Страница 623: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 2007ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 7 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2007ffff or 0x816f070c2007ffff Severity Info Serviceable No Auto...

Страница 624: ...Information Prefix PLAT ID 0127 User Response No action information only 816f070c 2009ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 9 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2009ffff or 0x816f070c2009ffff Severity Info Serviceable No...

Страница 625: ...mation Prefix PLAT ID 0127 User Response No action information only 816f070c 200bffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted DIMM 11 This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c200bffff or 0x816f070c200bffff Severity Info Serviceable No Aut...

Страница 626: ...n Prefix PLAT ID 0127 User Response No action information only 816f070c 2581ffff Configuration error for PhysicalMemoryElementName on Subsystem MemoryElementName has deasserted All DIMMS This message is for the use case when an implementation has detected a Memory DIMM configuration error has deasserted May also be shown as 816f070c2581ffff or 0x816f070c2581ffff Severity Info Serviceable No Automa...

Страница 627: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0401ffff Rebuild completed for Array in system ComputerSystemElementName Drive 1 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0401ffff or 0x816f070d0401ffff Severity Info Serviceable No Automatically notify support No Alert Category S...

Страница 628: ...Information Prefix PLAT ID 0179 User Response No action information only 816f070d 0403ffff Rebuild completed for Array in system ComputerSystemElementName Drive 3 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0403ffff or 0x816f070d0403ffff Severity Info Serviceable No Automatically notify support No Alert Categ...

Страница 629: ...mation Prefix PLAT ID 0179 User Response No action information only 816f070d 0405ffff Rebuild completed for Array in system ComputerSystemElementName Drive 5 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0405ffff or 0x816f070d0405ffff Severity Info Serviceable No Automatically notify support No Alert Category S...

Страница 630: ...Information Prefix PLAT ID 0179 User Response No action information only 816f070d 0407ffff Rebuild completed for Array in system ComputerSystemElementName Drive 7 This message is for the use case when an implementation has detected that an Array Rebuild has Completed May also be shown as 816f070d0407ffff or 0x816f070d0407ffff Severity Info Serviceable No Automatically notify support No Alert Categ...

Страница 631: ...Response No action information only 816f0807 0302ffff ProcessorElementName has been Enabled CPU 2 This message is for the use case when an implementation has detected a Processor has been Enabled May also be shown as 816f08070302ffff or 0x816f08070302ffff Severity Info Serviceable No Automatically notify support No Alert Category System Other SNMP Trap ID CIM Information Prefix PLAT ID 0060 User R...

Страница 632: ...ementName has recovered from an Uncorrectable Bus Error DIMMs This message is for the use case when an implementation has detected a that a system has recovered from a Bus Uncorrectable Error May also be shown as 816f08132581ffff or 0x816f08132581ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other SNMP Trap ID 50 CIM Information Prefix PLAT ID 0241 User ...

Страница 633: ...information only 816f0813 2584ffff System ComputerSystemElementName has recovered from an Uncorrectable Bus Error CPUs This message is for the use case when an implementation has detected a that a system has recovered from a Bus Uncorrectable Error May also be shown as 816f08132584ffff or 0x816f08132584ffff Severity Info Serviceable No Automatically notify support No Alert Category Critical Other ...

Страница 634: ...Information Prefix PLAT ID 0143 User Response No action information only 816f090c 2002ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 2 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2002ffff or 0x816f090c2002ffff Severity Info Serviceable No Automatically notify support No Al...

Страница 635: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 2004ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 4 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2004ffff or 0x816f090c2004ffff Severity Info Serviceable No Automatically notify support No Alert C...

Страница 636: ...Information Prefix PLAT ID 0143 User Response No action information only 816f090c 2006ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 6 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2006ffff or 0x816f090c2006ffff Severity Info Serviceable No Automatically notify support No Al...

Страница 637: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 2008ffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 8 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c2008ffff or 0x816f090c2008ffff Severity Info Serviceable No Automatically notify support No Alert C...

Страница 638: ...nformation Prefix PLAT ID 0143 User Response No action information only 816f090c 200affff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 10 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c200affff or 0x816f090c200affff Severity Info Serviceable No Automatically notify support No Al...

Страница 639: ...mation Prefix PLAT ID 0143 User Response No action information only 816f090c 200cffff PhysicalMemoryElementName on Subsystem MemoryElementName is no longer Throttled DIMM 12 This message is for the use case when an implementation has detected Memory is no longer Throttled May also be shown as 816f090c200cffff or 0x816f090c200cffff Severity Info Serviceable No Automatically notify support No Alert ...

Страница 640: ...Information Prefix PLAT ID 0039 User Response No action information only 816f0a07 0302ffff The Processor ProcessorElementName is no longer operating in a Degraded State CPU 2 This message is for the use case when an implementation has detected a Processor is no longer running in the Degraded state May also be shown as 816f0a070302ffff or 0x816f0a070302ffff Severity Info Serviceable No Automaticall...

Страница 641: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2002ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 2 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2002ffff or 0x816f0a0c2002ffff Seve...

Страница 642: ...Information Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2004ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 4 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2004ffff or 0x816f0a0c2004ffff...

Страница 643: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2006ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 6 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2006ffff or 0x816f0a0c2006ffff Seve...

Страница 644: ...Information Prefix PLAT ID 0147 User Response No action information only 816f0a0c 2008ffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 8 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c2008ffff or 0x816f0a0c2008ffff...

Страница 645: ...mation Prefix PLAT ID 0147 User Response No action information only 816f0a0c 200affff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 10 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c200affff or 0x816f0a0c200affff Sev...

Страница 646: ...Information Prefix PLAT ID 0147 User Response No action information only 816f0a0c 200cffff An Over Temperature Condition has been removed on the PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 12 This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Removed May also be shown as 816f0a0c200cffff or 0x816f0a0c200cfff...

Страница 647: ...mation Prefix PLAT ID 0245 User Response No action information only 816f0a13 0302ffff System ComputerSystemElementName has recovered from a Fatal Bus Error CPU 2 PECI This message is for the use case when an implementation has detected that a system has recovered from a Bus Fatal Error May also be shown as 816f0a130302ffff or 0x816f0a130302ffff Severity Info Serviceable No Automatically notify sup...

Страница 648: ...CI Error Yes 806f0021 3001ffff Fault in slot PhysicalConnectorSystemElementName on system ComputerSystemElementName PCI 1 3 Yes 806f0108 0a01ffff PowerSupplyElementName has Failed Power Supply 1 Yes 806f0108 0a02ffff PowerSupplyElementName has Failed Power Supply 2 Yes 806f010c 2001ffff Uncorrectable error detected for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 1 Yes 806f010c 20...

Страница 649: ...geVolumeElementName has been disabled due to a detected fault Drive 2 Yes 806f010d 0403ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 3 Yes 806f010d 0404ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 4 Yes 806f010d 0405ffff The Drive StorageVolumeElementName has been disabled due to a detected fault Drive 5 Yes 806f0...

Страница 650: ...sicalMemoryElementName on Subsystem MemoryElementName DIMM 2 Yes 806f050c 2003ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 3 Yes 806f050c 2004ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryElementName DIMM 4 Yes 806f050c 2005ffff Memory Logging Limit Reached for PhysicalMemoryElementName on Subsystem MemoryE...

Страница 651: ...failed Drive 2 Yes 806f060d 0403ffff Array ComputerSystemElementName has failed Drive 3 Yes 806f060d 0404ffff Array ComputerSystemElementName has failed Drive 4 Yes 806f060d 0405ffff Array ComputerSystemElementName has failed Drive 5 Yes 806f060d 0406ffff Array ComputerSystemElementName has failed Drive 6 Yes 806f060d 0407ffff Array ComputerSystemElementName has failed Drive 7 Yes 806f0813 2581fff...

Страница 652: ...638 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 653: ...s usually a user action or a change of states that is normal behavior Warning A warning is not as severe as an error but if possible the condition should be corrected before it becomes an error It might also be a condition that requires additional monitoring or maintenance Error An error typically indicates a failure or critical condition that impairs service or an expected function User response ...

Страница 654: ...s 1 If this is a newly installed option ensure that matching Processors are installed in the correct Processor sockets according to the service information for this product 2 Check IBM support site for an applicable service bulletin that applies to this Processor error 3 Trained Service technician only Replace Processor Inspect Processor socket and replace the system board first if socket is damag...

Страница 655: ... DIMMs are installed in the correct population sequence according to the service information for this product Correct any configuration issues found 2 Trained Service technician only Replace associated Processor Inspect Processor socket and replace the system board first if socket is damaged I 18009 I 18009 A core speed mismatch has been detected for one or more processor packages Explanation Proc...

Страница 656: ...1 Verify that matching processors are installed in the correct processor sockets according to the service information for this product Correct any mismatch found 2 Check IBM support site for an applicable service bulletin or firmware update that applies to this Processor error 3 Trained Service technician only Replace the system board I 1800C I 1800C A cache type mismatch has been detected for one...

Страница 657: ...ct 2 Check IBM support site for an applicable service bulletin or firmware update that applies to this Processor error 3 Trained Service technician only Replace the system board I 1800F I 1800F A processor family mismatch has been detected for one or more processor packages Explanation Processors have mismatched Family Severity Error User Response Complete the following steps 1 Verify that matchin...

Страница 658: ...nt slot If slot not available or error re occurs replace adapter 4 Trained Service technician only If adapter was moved to a different slot and error did not re occur verify that this is not a system limitation and then replace the system board Also if this is not the initial installation and the error persists after adapter replacement replace system board I 2018003 I 2018003 A bad option ROM che...

Страница 659: ... Log and Restart Server I 3818001 I 3818001 The firmware image capsule signature for the currently booted flash bank is invalid Explanation Current Bank CRTM Capsule Update Signature Invalid Severity Info User Response Complete the following steps 1 Reboot system Will come up on backup UEFI image Reflash the primary UEFI image 2 If error does not persist no additional recovery action is required 3...

Страница 660: ...If system fails to boot or if flash attempt fails Trained service technician only Replace the system board I 58015 I 58015 Memory spare copy initiated Explanation Spare Copy Started Severity Info User Response Complete the following steps 1 No user required for this event This is for informational purposes only I 580A4 I 580A4 Memory population change detected Explanation DIMM Population Change De...

Страница 661: ... the Processor S 1100C S 1100C An uncorrectable error has been detected on processor Explanation Uncorrectable processor error detected Severity Error User Response Complete the following steps 1 Check IBM support site for an applicable service bulletin or firmware update that applies to this error 2 Reboot system If problem persists escalate to the next level of supprt S 2011001 S 2011001 An Unco...

Страница 662: ...Device Driver c If device is not recognized reconfiguring slot to Gen1 or Gen2 may be required Gen1 Gen2 settings can be configured via F1 Setup System Settings Devices and I O Ports PCIe Gen1 Gen2 Gen3 Speed Selection or the ASU Utility 2 Check IBM support site for an applicable device driver firmware update version of service information for this product or other information that applies to this...

Страница 663: ...40007 A firmware fault has been detected in the UEFI image Explanation Internal UEFI Firmware Fault Detected System halted Severity Error User Response Complete the following steps 1 Check IBM support site for an applicable service bulletin or firmware update that applies to this error 2 Reflash UEFI image 3 Trained service technician only Replace the system board S 3050007 S 3050007 A firmware fa...

Страница 664: ...ate that applies to this error 5 Reflash UEFI firmware 6 Remove and re install CMOS battery for 30 seconds to clear CMOS contents 7 Trained service technician only Replace the system board S 3060007 S 3060007 A firmware fault has been detected in the UEFI image Explanation Internal UEFI Firmware Fault Detected System halted Severity Error User Response Complete the following steps 1 Check IBM supp...

Страница 665: ...echnician only Replace the system board S 3818007 S 3818007 The firmware image capsules for both flash banks could not be verified Explanation CRTM image capsule could not be verified Severity Error User Response Complete the following steps 1 If system failed to boot successfully DC cycle system 2 If system boots to F1 steup flash UEFI image and reset bank to primary if required If system boots w...

Страница 666: ... connector for damage If found replace system board 6 Trained Service technician only Replace affected Processor 7 Trained Service technician only Replace system board S 51006 S 51006 A memory mismatch has been detected Please verify that the memory configuration is valid Explanation One or More Mismatched DIMMs Detected Severity Error User Response Complete the following steps 1 Could follow an u...

Страница 667: ...nnector swap the other DIMMs on the same memory channel across channels one at a time to a different memory channel or Processor check service information for this product Install guide for population requirements for sparing paring modes If problem follows a moved DIMM to a different memory channel replace that DIMM 5 Check IBM support site for an applicable service bulletin or firmware update th...

Страница 668: ...oard Trained Service technician only 4 Trained Service Technician Only Replace the processor S 680B9 S 680B9 External QPI Link Failure Detected Explanation External QPI Link Failure Detected Severity Error User Response Complete the following steps 1 Check IBM support site for an applicable service bulletin or firmware update that applies to this error 2 Inspect processor socket for foreign debris...

Страница 669: ...er to UEFI Recovery section of service information for this product 3 Trained service technician only Replace the system board W 305000A W 305000A An invalid date and time have been detected Explanation RTC Date and Time Incorrect Severity Warning User Response Complete the following steps 1 Check IMM chassis event log This event should immediately precede 0068002 error Service that event or any o...

Страница 670: ... Required Controller Explanation DRIVER HEALTH PROTOCOL Reports Reboot Required Controller Severity Warning User Response Complete the following steps 1 No action required system will reboot at the end of POST 2 If problem persists switch to backup UEFI or reflash current UEFI image 3 Trained Service Technician Only Replace system board W 305800C W 305800C DRIVER HEALTH PROTOCOL Reports System Shu...

Страница 671: ...h current UEFI image 3 Trained Service Technician Only Replace system board W 3808000 W 3808000 An IMM communication failure has occurred Explanation IMM Communication Failure Severity Warning User Response Complete the following steps 1 Reset IMM 2 Remove AUX power from the system This will reboot the entire system 3 Check IBM support site for an applicable service bulletin or firmware update tha...

Страница 672: ...plicable service bulletin or firmware update that applies to this error 5 Reflash IMM Firmware 6 Remove and re install CMOS battery for 30 seconds to clear CMOS contents 7 Trained Service technician only Replace the system board W 3818005 W 3818005 The CRTM flash driver could not successfully flash the staging area The update was aborted Explanation CRTM Update Aborted Severity Warning User Respon...

Страница 673: ...e of a memory fault follow the procedure for that event 2 If no memory fault is recorded in the logs and no DIMM connector error LEDs are lit re enable the DIMM through the Setup utility or the Advanced Settings Utility ASU 3 If problem persists Power cycle the node 4 Reset IMM to default settings 5 Reset UEFI to default settings 6 Reflash IMM and UEFI firmware 7 Trained Service technician only Re...

Страница 674: ...nnector for foreign material and remove if found If connector is damaged replace system board 7 Trained service technician only Remove affected Processor and inspect Processor socket pins for damaged or mis aligned pins If damage is found or Processor is an upgrade part replace system board 8 Trained Service technician only Replace affected processor 9 Trained Service technician only Replace syste...

Страница 675: ...the service information for this product W 68002 W 68002 A CMOS battery error has been detected Explanation CMOS Battery Fault Severity Error User Response Complete the following steps 1 If the system was recently Installed Moved or Serviced makesure the batter is properly seated 2 Check IBM support site for an applicable service bulletin or firmware update that applies to this error 3 Replace CMO...

Страница 676: ...662 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 677: ... result when you run the DSA Broadcom network test 405 000 000 BRCM TestControlRegisters Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 001 000 BRCM TestMIIRegisters Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify ...

Страница 678: ... 405 003 000 BRCM TestInternalMemory Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 004 000 BRCM TestInterrupt Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No 664 Lenovo System x3530 M4 Installation and ...

Страница 679: ... No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 006 000 BRCM TestLoopbackPhysical Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 007 000 BRCM TestLEDs Test Passed The test passed Recoverable No Appendix C DSA diagnostic te...

Страница 680: ...e No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 801 000 BRCM TestMIIRegisters Test Aborted The MII register test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 666 Lenovo Sys...

Страница 681: ...3 000 BRCM TestInternalMemory Test Aborted The internal memory test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 804 000 BRCM TestInterrupt Test Aborted The interrupt test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Appendi...

Страница 682: ...upport website Latest level of DSA Latest level of BMC IMM 405 806 000 BRCM TestLoopbackPhysical Test Aborted Loopback testing at the physical layer was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 807 000 BRCM TestLEDs Test Aborted Verification of status LEDs was canceled R...

Страница 683: ...nt firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 405 ...

Страница 684: ...ed while testing non volatile RAM Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure remains refer to Troubleshooting...

Страница 685: ...TestInterrupt Test Failed A failure was detected while testing interrupts Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If ...

Страница 686: ... of BMC IMM 405 906 000 BRCM TestLoopbackPhysical Test Failed A failure was detected during the loopback test at the physical layer Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firm...

Страница 687: ...mponent 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA Brocade test results The following messages can result when you run the Brocade test Test results for the DSA Brocade test The following messages can result whe...

Страница 688: ...ated links IBM Support website Latest level of DSA Latest level of BMC IMM 218 002 000 Brocade SerdesLoopbackTest Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 003 000 Brocade PCILoopbackTest Passed The test passed Recoverable No 674 Lenovo System x3530 M4 Install...

Страница 689: ...verable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 005 000 Brocade SerdesEthLoopbackTest Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM Appendix C DSA diagnostic tes...

Страница 690: ...8 800 000 Brocade MemoryTest Aborted The test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 801 000 Brocade ExternalLoopbackTest Aborted The test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No 676 Lenovo System x3530 M4 Install...

Страница 691: ...lated links IBM Support website Latest level of DSA Latest level of BMC IMM 218 803 000 Brocade PCILoopbackTest Aborted The test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 804 000 Brocade ExternalEthLoopbackTest Aborted The test was canceled Recoverable No Appendix C D...

Страница 692: ...o Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 806 000 Brocade InternalLoopbackTest Aborted The test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 678 Lenovo System x3530 M4 I...

Страница 693: ...port representative Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 901 000 Brocade ExternalLoopbackTest Failed A failure was detected during the Loopback test Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check cable connections 2 Rerun the test 3 Verify whether the firmware is at proper...

Страница 694: ... problem remains contact your IBM technical support representative Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 903 000 Brocade PCILoopbackTest Failed A failure was detected during the Loopback test Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Rerun the test 2 Verify whether the firmw...

Страница 695: ...P cable 2 Rerun the test 3 Verify whether the firmware is at proper level 4 Rerun the test 5 If the problem remains contact your IBM technical support representative Related links IBM Support website Latest level of DSA Latest level of BMC IMM 218 905 000 Brocade SerdesEthLoopbackTest Failed A failure was detected during the Loopback test Recoverable No Severity Error Serviceable Yes Automatically...

Страница 696: ... the following steps 1 Rerun the test 2 Verify whether the firmware is at proper level 3 Rerun the test 4 If the problem remains contact your IBM technical support representative Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA checkpoint panel test results The following messages can result when you run the checkpoint panel test Test results for the DSA checkpoint ...

Страница 697: ... No User Response Complete the following steps 1 Inspect and reseat operator information panel cable at both ends 2 Verify that the Baseboard Management Controller BMC is working 3 Run the test again 4 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level ...

Страница 698: ...ymptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA CPU stress test results The following messages can result when you run the CPU stress test Test results for the DSA CPU stress test The following messages can result when you run the DSA CPU stress test 089 000 000 CPU Stress Test Pass...

Страница 699: ...ction for this component The latest level firmware for this component can be found in reference to this system type at the IBM Support websit 5 Run the test again 6 If the system has stopped responding turn off and restart the system and then run the test again 7 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Relat...

Страница 700: ...ubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 089 803 000 CPU Stress Test Aborted CPU Stress Test Aborted Memory size is insufficient to run the test At least 1GB is required Recoverable No Severity Warning Serviceable Yes Automatically notify support No Related links...

Страница 701: ...found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 5 Run the test again 6 If the system has stopped responding turn off and restart the system and then run the test again 7 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Late...

Страница 702: ...ackTest Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 516 002 000 ELXUCNA ELXUCNA NIC LED Beacon Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links 688 Lenovo System x3530 M4 Installation and Service ...

Страница 703: ... Latest level of DSA Latest level of BMC IMM 516 801 000 ELXUCNA NIC PHY LoopBackTest Aborted Loopback testing at the physical layer was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 516 802 000 ELXUCNA ELXUCNA NIC LED Beacon Test Aborted Verification of status LEDs was canceled ...

Страница 704: ...ssary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 516 901 000 ELXUCNA NIC PHY LoopBackTest ...

Страница 705: ...able No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation an...

Страница 706: ...tify support No User Response Complete the following steps 1 Remove power cables wait for 45 seconds reconnect and rerun the test 2 Make sure that the scalability cable connections are as per specification 3 Make sure that DSA and BIOS uEFI are at the latest level 4 If the problem remains contact your technical service representative Related links IBM Support website Latest level of DSA Latest lev...

Страница 707: ...st level of BMC IMM 401 901 001 EXA Port Ping Test Failed EXA Port Ping Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Remove power cables wait for 45 seconds reconnect and rerun the test 2 Make sure that the scalability cable connections are as per specification 3 Check scalability cables for loose connections...

Страница 708: ...port No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 217 800 000 HDD Test Aborted HDD Test Aborted The test was canceled Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check cable connections 2 Rerun the test 3 Verify that Hard drive supports self test and self test logging 4 If the probl...

Страница 709: ...e is at the latest level 4 Rerun the test 5 If the problem remains contact your technical support representative Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA Intel network test results The following messages can result when you run the Intel network test Test results for the DSA Intel network test The following messages can result when you run the DSA Intel net...

Страница 710: ...e No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 406 002 000 IANet FIFO Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 406 003 000 IANet Interrupts Test Passed 696 Lenovo System x3530 M4 Installatio...

Страница 711: ...pback Test Passed The test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 406 800 000 IANet Registers Test Aborted Registers test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links Appendix C DSA diagnostic test results 697 ...

Страница 712: ...ort website Latest level of DSA Latest level of BMC IMM 406 802 000 IANet FIFO Test Aborted FIFO test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 406 803 000 IANet Interrupts Test Aborted Interrupt test was canceled Recoverable No Severity Warning 698 Lenovo System x3530 M4...

Страница 713: ... Registers Test Failed A failure was detected during the Registers test Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check component firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 If fa...

Страница 714: ... Rerun the test 3 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 406 902 000 IANet FIFO Test Failed A failure was detected during the FIFO test Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Co...

Страница 715: ...ound in the DSA Diagnostic Event Log within the Firmware VPD section for this component 2 Rerun the test 3 Check interrupt assignments in the PCI Hardware section of the DSA Diagnostic Log If the ethernet device is sharing interrupts if possible modify the interrupt assignments using F1 Setup to assign a unique interrupt to the device 4 Rerun the test 5 If failure remains refer to Troubleshooting ...

Страница 716: ... next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA LSI hard drive test results The following messages can result when you run the LSI hard drive test Test results for the DSA LSI hard driveoutputfilename DSA_LSI_hard_drive test The following messages can result when you run the DSA LSI hard driveoutputfilename DSA_LSI_hard_drive test 407 000 0...

Страница 717: ... Failed The hard drive self test detected a failure Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check cable connections 2 Rerun the test 3 Verify whether the firmware is at the latest level 4 Rerun the test 5 If the problem remains contact your IBM technical support representative Related links IBM Support website Lates...

Страница 718: ...o Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 408 001 000 MLNX MLNX_DiagnosticTestIBPort Test Passed Port Test Passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 408 800 000 MLNX MLNX_Diagnosti...

Страница 719: ...port No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 408 900 000 MLNX MLNX_DiagnosticTestEthernetPort Test Failed Port Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Make sure that the physical link of the port under test in the active state 2 If these condition was met but the ...

Страница 720: ...bric to which the port is attached 2 If these condition was met but the test keeps failing the port s adapter might be faulty 3 Try replacing the adapter and repeating the test Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA memory isolation test results The following messages can result when you run the memory isolation test Test results for the DSA memory isolat...

Страница 721: ...erable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 000 002 Standalone Memory Test Passed Quick Full Memory Test CPU 2 Passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM Appendix C DSA di...

Страница 722: ...00 004 Standalone Memory Test Passed Quick Full Memory Test CPU 4 Passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 811 000 Standalone Memory Test Aborted Unable to Locate SMBIOS key _SM_ Recoverable No Severity Warning Serviceable No Automatically notify support No 708 Lenovo System...

Страница 723: ... Locate SMBIOS key _SM_ Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to p...

Страница 724: ...ory Test Aborted Unable to Locate SMBIOS key _SM_ Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Resea...

Страница 725: ...evel of DSA Latest level of BMC IMM 201 812 001 Standalone Memory Test Aborted Memory test is not supported for this system Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 ...

Страница 726: ...FI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 812 003 Standalone Memory Test Aborted Memory test is not supported for this system Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If...

Страница 727: ... the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 813 001 Standalone Memory Test Aborted Chipset Error Can not turn OFF ECC error reporting in CPU Recoverable No Severity Warning Serviceable No Automatically noti...

Страница 728: ...e following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest lev...

Страница 729: ...cubbing feature for CPU Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to p...

Страница 730: ... Chipset Error Can not disable Scubbing feature for CPU Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds...

Страница 731: ...of DSA Latest level of BMC IMM 201 815 000 Standalone Memory Test Aborted Program Error with Quick Memory Menu Option Selection Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representativ...

Страница 732: ...FI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 815 002 Standalone Memory Test Aborted Program Error with Quick Memory Menu Option Selection Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each ac...

Страница 733: ...f the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 816 000 Standalone Memory Test Aborted Program Error with Full Memory Menu Option Selection Recoverable No Severity Warning Serviceable No Automatically notify s...

Страница 734: ...e following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest lev...

Страница 735: ...Full Memory Menu Option Selection Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconne...

Страница 736: ...ne Memory Test Aborted Unable to Locate SMBIOS key _SM_ Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds...

Страница 737: ...test level of DSA Latest level of BMC IMM 201 818 003 Standalone Memory Test Aborted Unable to Locate SMBIOS key _SM_ Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn o...

Страница 738: ...FI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 819 001 Standalone Memory Test Aborted The start end address ranges in the restricted area of the memory Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test a...

Страница 739: ... the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 819 003 Standalone Memory Test Aborted The start end address ranges in the restricted area of the memory Recoverable No Severity Warning Serviceable No Automatica...

Страница 740: ...e following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest lev...

Страница 741: ... is less than 16 Mbytes Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to p...

Страница 742: ...RR registers are larger than fixed range MTRR registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds...

Страница 743: ...test level of BMC IMM 201 821 002 Standalone Memory Test Aborted Variable range MTRR registers are larger than fixed range MTRR registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service rep...

Страница 744: ...e that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 822 000 Standalone Memory Test Aborted Invalid MTRR service request Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each actio...

Страница 745: ... the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 822 002 Standalone Memory Test Aborted Invalid MTRR service request Recoverable No Severity Warning Serviceable No Automatically notify support No User Response C...

Страница 746: ...mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 824 000 Standalone Mem...

Страница 747: ...on and then re run the test Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it ...

Страница 748: ...orted Node Interleave feature must be OFF Go to Setup and disable Node Interleave option and then re run the test Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off t...

Страница 749: ...links IBM Support website Latest level of DSA Latest level of BMC IMM 201 826 001 Standalone Memory Test Aborted BIOS Memory Controller has been disabled Go to Setup and Enable Memory Controller Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 ...

Страница 750: ...hat DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 826 003 Standalone Memory Test Aborted BIOS Memory Controller has been disabled Go to Setup and Enable Memory Controller Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mention...

Страница 751: ...urn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 827 001 Standalone Memory Test Aborted BIOS ECC function has been disabled by BIOS Go to Setup and enable ECC generation Recoverable No Severity Warning Se...

Страница 752: ...e following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest lev...

Страница 753: ... control MASK registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to p...

Страница 754: ...lem in masking MSR machine check control MASK registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds...

Страница 755: ... Latest level of BMC IMM 201 845 000 Standalone Memory Test Aborted Chipset Error Problem clearing MSR machine check control registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service repres...

Страница 756: ...FI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 845 002 Standalone Memory Test Aborted Chipset Error Problem clearing MSR machine check control registers Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test ...

Страница 757: ...presentative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 859 000 Standalone Memory Test Aborted INVALID XSECSRAT type Recoverable No Severity Warning Serviceable No Automatically notify support No...

Страница 758: ...e following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest lev...

Страница 759: ...ed INVALID XSECSRAT type Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to ...

Страница 760: ...001 Standalone Memory Test Aborted No OEM0 type 1 found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds...

Страница 761: ...ite Latest level of DSA Latest level of BMC IMM 201 860 003 Standalone Memory Test Aborted No OEM0 type 1 found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the...

Страница 762: ...FI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 861 001 Standalone Memory Test Aborted No SRAT type 1 found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains con...

Страница 763: ... the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 861 003 Standalone Memory Test Aborted No SRAT type 1 found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete ...

Страница 764: ...e following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest lev...

Страница 765: ...No OEM1 structure found Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to p...

Страница 766: ...e Memory Test Aborted No IBMERROR key in OEM1 structure Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds...

Страница 767: ...est level of DSA Latest level of BMC IMM 201 863 002 Standalone Memory Test Aborted No IBMERROR key in OEM1 structure Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn o...

Страница 768: ...OS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 864 000 Standalone Memory Test Aborted No GAS located in OEM1 Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem rema...

Страница 769: ... the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 864 002 Standalone Memory Test Aborted No GAS located in OEM1 Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complet...

Страница 770: ...owing steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of ...

Страница 771: ...T key in OEM0 structure Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to p...

Страница 772: ...Test Aborted No XSECSRAT key in OEM0 structure Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat D...

Страница 773: ... of DSA Latest level of BMC IMM 201 866 001 Standalone Memory Test Aborted EFI SAL Invalid parameter from GetMemoryMap function Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representativ...

Страница 774: ...FI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 866 003 Standalone Memory Test Aborted EFI SAL Invalid parameter from GetMemoryMap function Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each act...

Страница 775: ... the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 867 001 Standalone Memory Test Aborted EFI SAL Buffer not allocated Recoverable No Severity Warning Serviceable No Automatically notify support No User Response C...

Страница 776: ...e following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest lev...

Страница 777: ... GetMemoryMap too small Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to p...

Страница 778: ...rted EFI SAL Buffer allocated in GetMemoryMap too small Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds...

Страница 779: ... of DSA Latest level of BMC IMM 201 869 000 Standalone Memory Test Aborted EFI SAL Invalid parameter from GetMemoryMap function Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representativ...

Страница 780: ...FI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 869 002 Standalone Memory Test Aborted EFI SAL Invalid parameter from GetMemoryMap function Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each act...

Страница 781: ...e 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 870 000 Standalone Memory Test Aborted CPU Doamin in ACPI not valid Recoverable No Severity Warning Serviceable No Automatically notify support No Use...

Страница 782: ...e following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest lev...

Страница 783: ...oamin in ACPI not valid Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to p...

Страница 784: ...dalone Memory Test Aborted Data Mis compare encountered Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds...

Страница 785: ...Latest level of DSA Latest level of BMC IMM 201 871 003 Standalone Memory Test Aborted Data Mis compare encountered Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off...

Страница 786: ...FI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 877 001 Standalone Memory Test Aborted BIOS Sparing in Extended PCI reg must be OFF Go to setup and disable sparing Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try...

Страница 787: ... the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 877 003 Standalone Memory Test Aborted BIOS Sparing in Extended PCI reg must be OFF Go to setup and disable sparing Recoverable No Severity Warning Serviceable No...

Страница 788: ...e following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest lev...

Страница 789: ...the sparing feature OFF Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to p...

Страница 790: ...ster manipulation Can not write to memory without cache Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds...

Страница 791: ... of BMC IMM 201 885 002 Standalone Memory Test Aborted Processor does not support MTRR register manipulation Can not write to memory without cache Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical se...

Страница 792: ...sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 886 000 Standalone Memory Test Aborted Memory Upper limit is less than 16 Mbytes Recoverable No Severity Warning Serviceable No Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test ...

Страница 793: ... the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 886 002 Standalone Memory Test Aborted Memory Upper limit is less than 16 Mbytes Recoverable No Severity Warning Serviceable No Automatically notify support No Us...

Страница 794: ...he following steps 1 Perform the actions mentioned one at a time and try the test after each action 2 If the problem remains contact your technical service representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level Related links IBM Support website Latest level of DSA Latest le...

Страница 795: ...links IBM Support website Latest level of DSA Latest level of BMC IMM 201 899 002 Standalone Memory Test Aborted Memory Diagnostics Test Aborted by user Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 899 003 Standalone Memory Test Aborted Memory Diagnostics Test Aborted by user Recover...

Страница 796: ...e representative 3 Turn off the system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level 5 Replace any DIMMS s mentioned in error one by one 6 Make sure that all DIMMs are enabled in the Configuration Setup Utility program 7 If failure remains refer to Troubleshooting by symptom in the system Installation...

Страница 797: ... Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 201 901 002 Standalone Memory Test Failed Memory Diagnostics Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Perform the actions mentioned one at a time and try the test af...

Страница 798: ... system and disconnect it from power Wait for 45 seconds Reseat DIMM s Reconnect it to power 4 Make sure that DSA and BIOS uEFI are at the latest level 5 Replace any DIMMS s mentioned in error one by one 6 Make sure that all DIMMs are enabled in the Configuration Setup Utility program 7 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next...

Страница 799: ...ps 1 Turn off and restart the system 2 Make sure that the DSA Diagnostic code is at the latest level 3 Run the test again 4 If the system has stopped responding turn off and restart the system 5 Check the system firmware level and upgrade if necessary 6 Run the memory diagnostic to identify the specific failing DIMM 7 If the failure remains refer to Troubleshooting by symptom in the system Install...

Страница 800: ...level of DSA Latest level of BMC IMM 202 803 000 MemStr Test Aborted User pressed Ctrl C Recoverable No Severity Warning Serviceable Yes Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 202 901 000 MemStr Test Failed Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No 786 Lenovo System x3530 M4 Insta...

Страница 801: ...t Failed Memory size is insufficient to run the test Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Ensure that all memory is enabled by checking the Available System Memory in the Resource Utilization section of the DSA Diagnostic Event log 2 If necessary access the Configuration Setup Utility program by pressing F1 durin...

Страница 802: ...ity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 409 003 000 Nvidia DiagnosticServiceProvider Bandwidth Test Passed Nvidia GPU Bandwidth test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 409 004 00...

Страница 803: ...trix Test Passed Nvidia GPU Matrix test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 409 006 000 Nvidia DiagnosticServiceProvider Binomial Test Passed Nvidia GPU Binomial test passed Recoverable No Severity Event Serviceable No Automatically notify support No Related links Appendix ...

Страница 804: ... DSA Latest level of BMC IMM 409 803 000 Nvidia DiagnosticServiceProvider Bandwidth Test Aborted Nvidia GPU Bandwidth test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 409 804 000 Nvidia DiagnosticServiceProvider Query Test Aborted Nvidia GPU Query test was canceled Recovera...

Страница 805: ...ble No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 409 806 000 Nvidia DiagnosticServiceProvider Binomial Test Aborted Nvidia GPU Binomial test was canceled Recoverable No Severity Warning Serviceable No Automatically notify support No Related links IBM Support website Latest level of DSA Latest level of BMC IMM 409 900 000 NVIDIA Us...

Страница 806: ... Related links IBM Support website Latest level of DSA Latest level of BMC IMM 409 903 000 Nvidia DiagnosticServiceProvider Bandwidth Test Failed Nvidia GPU Bandwidth Test Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU Then power cycle the...

Страница 807: ...irmly Then power cycle the system 3 Run nvidia smi q In some cases this will report a poorly connected power cable 4 Rerun the diagnostics using the same GPU on system that is known to be working A variety of system issues can cause diagnostic failure 5 If the problem remains contact your IBM technical support representative Related links IBM Support website Latest level of DSA Latest level of BMC...

Страница 808: ...st Failed Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU Then power cycle the system 2 Verify that the power connectors to the GPU are connected firmly Then power cycle the system 3 Run nvidia smi q In some cases this will report a poorly connect...

Страница 809: ...Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Make sure that the DSA Diagnostic code is at the latest level 2 Run the test again 3 Check the drive cabling for loose or broken connections at both ends or damage to the cable Replace the cable if damage is present 4 Run the test again 5 Check system firmware level and upgr...

Страница 810: ...ds or damage to the cable Replace the cable if damage is present 3 Run the test again 4 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 215 803 000 Optical Drive Test Failed Optical Drive Test Failed Disk may be in use by the operating sys...

Страница 811: ... a new CD or DVD into the drive and wait for 15 seconds for the media to be recognized Rerun the test 3 Check the drive cabling for loose or broken connections at both ends or damage to the cable Replace the cable if damage is present 4 Run the test again 5 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related lin...

Страница 812: ...Optical Drive Test Failed Read miscompare Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Insert a new CD or DVD into the drive and wait for 15 seconds for the media to be recognized Rerun the test 2 Check the drive cabling for loose or broken connections at both ends or damage to the cable Replace the cable if damage is pr...

Страница 813: ...ostic Event Log within the Firmware VPD section for this component 5 Run the test again 6 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM DSA system management test results The following messages can result when you run the system manageme...

Страница 814: ... power 2 Make sure that DSA and BMC IMM are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 166 802 001 IMM I2C Test Aborted Test cannot be completed for unknown reason Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn o...

Страница 815: ... 2 Make sure that DSA and BMC IMM are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 166 804 001 IMM I2C Test Aborted Invalid Command Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it fr...

Страница 816: ...e latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 166 806 001 IMM I2C Test Aborted Timeout while processing command Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 secon...

Страница 817: ...te Latest level of DSA Latest level of BMC IMM 166 808 001 IMM I2C Test Aborted Reservation Canceled or Invalid Reservation ID Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make ...

Страница 818: ...evel of BMC IMM 166 810 001 IMM I2C Test Aborted Request data length invalid Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level ...

Страница 819: ... IMM 166 812 001 IMM I2C Test Aborted Parameter out of range Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links IB...

Страница 820: ...est Aborted Requested Sensor data or record not present Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links IBM Sup...

Страница 821: ...d illegal for specified sensor or record type Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links IBM Support websi...

Страница 822: ...le No Severity Warning Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 166 819 ...

Страница 823: ... Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 166 821 001 IMM I2C Test Aborted Command respo...

Страница 824: ...stem and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level Related links IBM Support website Latest level of DSA Latest level of BMC IMM 166 823 001 IMM I2C Test Aborted Cannot execute command Insufficient privilege level Recoverable No Severity Warning Serviceable Yes Automatically notify support No User Response Perform th...

Страница 825: ...ted links IBM Support website Latest level of DSA Latest level of BMC IMM 166 901 001 IMM I2C Test Failed IMM Indicates failure in RTMM bus BUS 0 Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Perform the actions mentioned one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it...

Страница 826: ...evel 3 Run the test again 4 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 166 905 001 IMM I2C Test Failed IMM Indicates failure in PSU 1 bus BUS 4 Recoverable No Severity Error Serviceable Yes Automatically notify support No User Respons...

Страница 827: ...one at a time and try the test after each action 1 Turn off the system and disconnect it from power Wait for 45 seconds Reconnect it to power 2 Make sure that DSA and BMC IMM are at the latest level 3 Run the test again 4 If failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level ...

Страница 828: ...upport website Latest level of DSA Latest level of BMC IMM DSA tape drive test results The following messages can result when you run the tape drive test Test results for the DSA tape drive test The following messages can result when you run the DSA tape drive test 264 000 000 Tape Test Passed Tape Test Passed Recoverable No Severity Event Serviceable No Automatically notify support No Related lin...

Страница 829: ...ks IBM Support website Latest level of DSA Latest level of BMC IMM 264 902 000 Tape Test Failed Tape Test Failed Media is not detected Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Clean the tape drive using the appropriate cleaning media and install new media 2 Run the test again 3 Make sure that the drive firmware is at...

Страница 830: ... refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 264 904 000 Tape Test Failed Tape Test Failed Drive hardware error Recoverable No Severity Error Serviceable Yes Automatically notify support No User Response Complete the following steps 1 Check the tape driv...

Страница 831: ... stopped responding turn off and restart the system 2 Check the system firmware level and upgrade if necessary The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware VPD section for this component 3 Run the test again 4 If the system has stopped responding turn off and restart the system 5 Make sure that the drive firmware is at the latest level 6 Run the tes...

Страница 832: ...essary 8 Run the test again 9 If the failure remains refer to Troubleshooting by symptom in the system Installation and Service Guide for the next corrective action Related links IBM Support website Latest level of DSA Latest level of BMC IMM 264 907 000 Tape Test Failed An error was found in the block address somewhere Recoverable No Severity Error Serviceable Yes Automatically notify support No ...

Страница 833: ... Yes Automatically notify support No User Response Complete the following steps 1 Make sure that medium is present 2 Clean the tape drive using the appropriate cleaning media and install new media Related links IBM Support website Latest level of DSA Latest level of BMC IMM Appendix C DSA diagnostic test results 819 ...

Страница 834: ...820 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 835: ...have installed new hardware or software in your environment check http www lenovo com serverproven to make sure that the hardware and software is supported by your product Go to http www lenovo com support to check for information to help you solve the problem Gather the following information to provide to the service technician This data will help the service technician quickly provide a solution...

Страница 836: ...at http www lenovo com support The most current version of the product documentation is available in the following product specific Information Centers Flex System products http pic dhe ibm com infocenter flexsys information index jsp System x products http shop lenovo com us en systems NeXtScale System products http pic dhe ibm com infocenter nxtscale documentation index jsp How to send DSA data ...

Страница 837: ...upport IBM is Lenovo s preferred service provider for the System x Flex System and NeXtScale System products You can receive hardware service through your Lenovo reseller or from IBM To locate a reseller authorized by Lenovo to provide warranty service go to http www ibm com partnerworld and click Business Partner Locator For IBM support telephone numbers see http www ibm com planetwide In the U S...

Страница 838: ...824 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 839: ...ublication Lenovo may make improvements and or changes in the product s and or the program s described in this publication at any time without notice The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo...

Страница 840: ...f all hard disk drive bays with the largest currently supported drives that are available from Lenovo Maximum memory might require replacement of the standard memory with an optional memory module Each solid state memory cell has an intrinsic finite number of write cycles that the cell can incur Therefore a solid state device has a maximum number of write cycles that it can be subjected to express...

Страница 841: ...tered to 99 97 efficiency or greater using high efficiency particulate air HEPA filters that meet MIL STD 282 The deliquescent relative humidity of the particulate contamination must be more than 60 2 The room must be free of conductive contamination such as zinc whiskers Gaseous Copper Class G1 as per ANSI ISA 71 04 19853 Silver Corrosion rate of less than 300 Å in 30 days 1 ASHRAE 52 2 2008 Meth...

Страница 842: ...be required to take adequate measures European Union EMC Directive conformance statement This product is in conformity with the protection requirements of EU Council Directive 2014 30 EU on the approximation of the laws of the Member States relating to electromagnetic compatibility Lenovo cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non recom...

Страница 843: ...wortlich für die Konformitätserklärung nach Paragraf 5 des EMVG ist die Lenovo Deutschland GmbH Meitnerstr 9 D 70563 Stuttgart Informationen in Hinsicht EMVG Paragraf 4 Abs 1 4 Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse A Nach der EN 55022 Dies ist eine Einrichtung der Klasse A Diese Einrichtung kann im Wohnbereich Funkstörungen verursachen in diesem Fall kann vom ...

Страница 844: ...e Korea Communications Commission KCC statement This is electromagnetic wave compatibility equipment for business Type A Sellers and users need to pay attention to it This is for any areas other than home Russia Electromagnetic Interference EMI Class A statement People s Republic of China Class A electronic emission statement 830 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 845: ...Taiwan Class A compliance statement Appendix E Notices 831 ...

Страница 846: ...D F F D D I I a a D D D D D D D D D D a a D D D D D D D D D D X X U U X X U U Note1 exceeding 0 1wt and exceeding 0 01 wt indicate that the percentage content of the restricted substance exceeds the reference percentage value of presence condi on 1 1 P P U UF F L LO O E E J JD D B B U UF F T T U UI I B B U U U UI I F F S S F F S S D D F F O O U UB B H H F F F F P P O O U UF F O O U U P P G G U UI ...

Страница 847: ...ot swap SAS SATA removing 259 replacing 260 backup firmware starting 90 battery replacing 248 battery system installing 248 replacing 246 bays 6 best practices use to apply current firmware and device driver updates 23 bezel removing 190 blue screen capture features 11 81 blue screen capture feature overview 11 81 93 blue screen feature 93 boot manager program using 89 Business Partners instructio...

Страница 848: ... CRUs replacing adapter 193 CD or DVD drive 206 DIMMs 214 memory 214 system battery 246 custom support web page 823 customer replaceable units CRUs server 147 D danger statements 5 data collection 105 dc good LED 120 dc power LED 20 deassertion event system event log 121 device drivers 90 devices installing 23 devices static sensitive handling 33 diagnostic test log viewing 125 text message format...

Страница 849: ...k 135 optional devices 137 pointing device non USB 131 power 138 serial port 139 ServerGuide 139 software 140 USB port 141 errors format diagnostic code 125 power supply LEDs 119 Ethernet 11 controller troubleshooting 142 link status LED 20 Ethernet activity LED 16 20 Ethernet and system management connector 21 Ethernet support 10 European Union EMC Directive conformance statement 828 event log DS...

Страница 850: ...n sequence on the server 37 information center 822 inspecting for unsafe conditions vi installation guidelines 31 installation options completing 73 installing a fan 212 a heat sink 54 a hot swap power supply 57 a microprocessor 50 51 a PCI riser card assembly 45 a RAID adapter remote battery 67 220 a ServeRAID controller 218 an adapter 46 48 battery system 248 hot swap dc power supply 60 hot swap...

Страница 851: ...ns 6 memory installation sequence for independent mode 37 memory module installing 35 memory problems 133 memory support 10 memory mirroring mode 37 description 37 memory mirroring mode DIMM population sequence on the server 38 messages diagnostic 123 messages error POST 639 methods for viewing event logs 122 microprocessor 10 and thermal grease 55 269 associated with each DIMM 36 installing 50 51...

Страница 852: ...ower supply error LED 20 Preboot DSA 8 presence detection button 16 problem isolation tables 126 problems CD DVD drive 127 Ethernet controller 142 hard disk drive 129 hypervisor flash device 128 intermittent 130 memory 133 microprocessor 133 monitor 133 mouse 131 132 network 135 optional devices 137 pointing device 132 power 138 141 serial port 139 software 140 troubleshooting 105 undetermined 142...

Страница 853: ...set button 17 18 115 riser card assembly location 193 routing the configuration cable 165 170 179 the hardware RAID cable 168 173 177 182 186 the power cable 166 171 175 180 184 the remote RAID battery cable 164 the software RAID cable 169 174 178 183 187 Russia Class A electronic emission statement 830 S safety v safety statements v viii SAS SATA backplane supported configurations 200 SAS SATA dr...

Страница 854: ...21 system reliability guidelines 32 system event log 120 system event log assertion event 121 system event log deassertion event 121 Systems Director systems management tool 13 updating 98 systems management 8 11 systems management tool Systems Director 13 T Taiwan BSMI RoHS declaration 832 Taiwan Class A electronic emission statement 831 Taiwan product service 823 telecommunication regulatory sta...

Страница 855: ...5 rear 20 video controller integrated specifications 6 video problems 133 viewing event logs through the Setup utility 121 viewing event logs without restarting the server 121 W Wake on LAN feature 21 Web site UEFI flash diskette 144 weight 7 what the server offers 8 Copyright Lenovo 2015 2016 841 ...

Страница 856: ...842 Lenovo System x3530 M4 Installation and Service Guide ...

Страница 857: ......

Страница 858: ......

Отзывы: