2. Remove the drive that was being tested when the server stopped responding, and run the diagnostics
again.
A drive has failed with yellow LED lit
Complete the following steps until the problem is solved:
1. Check the Lenovo XClarity Controller event log for drive events and resolve the problem.
A newly installed drive is not recognized.
Complete the following steps until the problem is solved:
1. Set up RAID configuration.
2. Check the Lenovo XClarity Controller event log, and resolve related errors if found any.
3. If the LED is lit, remove the drive from the drive bay, wait 45 seconds, and reinsert the drive. Make sure
that the drive assembly connects to the drive backplane.
4. Observe the associated green drive activity LED and the yellow status LED:
• If the green activity LED is flashing and the yellow status LED is not lit, the drive is recognized by the
controller and is working correctly. Run the LXPM HDD test to determine whether the drive is
detected (see
http://sysmgt.lenovofiles.com/help/topic/LXPM/LXPM_introduction.html
).
• If the green activity LED is flashing and the yellow status LED is flashing slowly, the drive is
recognized by the controller and is rebuilding.
• If neither LED is lit or flashing, check the drive backplane.
• If the green activity LED is flashing and the yellow status LED is lit, replace the drive. If the activity of
the LEDs remain the same, go to step
5. If the activity of the LEDs changes, return to step 1. 5. Make sure that a drive backplane is present to
install the drive into.
6. Make sure that the drive backplane is correctly seated. When it is correctly seated, the drive assemblies
would be correctly connected to the backplane without bowing or causing movement of the backplane.
7. Reseat the backplane power cable and repeat step 1 to step 3.
8. Reseat the backplane signal cable and repeat step 1 to step 3.
9. Suspect the backplane signal cable or the backplane:
a. Replace the affected backplane signal cable.
b. Replace the affected backplane.
10. (Trained service technician only) replace the system board.
Drive(s) installed in the server are not detected by SAS controller
Complete the following steps until the problem is solved:
1. Verify if the drives are supported for this server. See the ServerProven web site at
www.lenovo.com/us/en/serverproven/
for a list of supported drives.
2. Check the Lenovo XClarity Controller event log, resolve drive related errors is found any.
3. Make sure that the drives are seated correctly, the SAS signal cables are securely connected, the
backplane cables are securely connected to the backplanes, and the RAID adapter is configured
correctly.
4. If the problem remains:
a. Reseat the backplane(s), SAS signal cable(s), and backplane power cable(s).
b. Restart the server.
176
ThinkSystem SR860 Maintenance Manual
Содержание ThinkSystem SR860
Страница 1: ...ThinkSystem SR860 Maintenance Manual Machine Type 7X69 7X70 ...
Страница 8: ...vi ThinkSystem SR860 Maintenance Manual ...
Страница 63: ...Figure 48 Server components Chapter 2 Server components 55 ...
Страница 200: ...192 ThinkSystem SR860 Maintenance Manual ...
Страница 210: ...202 ThinkSystem SR860 Maintenance Manual ...
Страница 211: ......
Страница 212: ...Part Number SP47A30805 Printed in China 1P P N SP47A30805 1PSP47A30805 ...