Figure 152. Installing a PHM
a. Align the triangular marks and guide pins on the processor socket with the PHM; then, insert
the PHM into the processor socket.
Attention:
To prevent damage to components, make sure that you follow the indicated
tightening sequence.
b. Fully tighten the Torx T30 captive fasteners
in the installation sequence shown
on the heat-sink
label. Tighten the screws until they stop; then, visually inspect to make sure that there is no
gap between the screw shoulder beneath the heat sink and the microprocessor socket. (For
reference, the torque required for the nuts to fully tighten is 1.4 — 1.6 newton-meters, 12 — 14
inch-pounds).
After installing a PHM:
1. Complete the parts replacement. See “Completing the parts replacement” on page 203.
System board replacement
Use this information to remove and install the system board.
S017
.
Hardware replacement procedures
193
Содержание ThinkSystem SR650
Страница 1: ...ThinkSystem SR650 Maintenance Manual Machine Types 7X05 and 7X06 ...
Страница 8: ...vi ThinkSystem SR650 Maintenance Manual ...
Страница 20: ...12 ThinkSystem SR650 Maintenance Manual ...
Страница 96: ...88 ThinkSystem SR650 Maintenance Manual ...
Страница 154: ...Figure 107 Riser 1 assembly removal 146 ThinkSystem SR650 Maintenance Manual ...
Страница 157: ...Figure 111 Installing the screws to secure the riser card Chapter 3 Hardware replacement procedures 149 ...
Страница 212: ...204 ThinkSystem SR650 Maintenance Manual ...
Страница 230: ...222 ThinkSystem SR650 Maintenance Manual ...
Страница 234: ...226 ThinkSystem SR650 Maintenance Manual ...
Страница 243: ......
Страница 244: ......