• RAID Level 0 - Striped disk array
– A RAID Level 0 hard disk drive group consisting of at least one hard disk drive
– Supported strip size: 8 KB to 1 MB
– Better performance without fault tolerance
• RAID Level 00 - Spanned hard disk drive group with a series of RAID 0 hard disk drive groups
– A RAID Level 00 hard disk drive group consisting of two or four hard disk drives
– Supported strip size: 8 KB to 1 MB
– Better performance without fault tolerance
• RAID Level 1 - Mirrored disk array
– A RAID Level 1 hard disk drive group consisting of two or four hard disk drives
– Improved read performance and 100% redundancy
• RAID Level 10 - A combination of RAID Level 0 and RAID Level 1
– A RAID Level 10 hard disk drive group consisting of four hard disk drives
– Data being striped across hard disk drive groups
– Provides both high data transfer rates and complete data redundancy
• RAID Level 5 - Block-level striped disk array with distributed parity
– A RAID Level 5 hard disk drive group consisting of at least three hard disk drives
– Supported strip size: 8 KB to 1 MB
– Better performance and fault tolerance
– RAID Level 5 might not be available on all models of AVAGO MegaRAID adapter
• RAID Level 6 - Block-level striped disk array with dual distributed parity
– A RAID Level 6 hard disk drive group consisting of at least four hard disk drives
– Supported strip size: 8 KB to 1 MB
– Better performance and fault tolerance that can stand up to loss of two hard disk drives
– RAID Level 6 might not be available on all models of AVAGO MegaRAID adapter
Ensure that the AVAGO MegaRAID SAS adapter card is installed in your computer, and that the hard disk
drives are connected to this adapter card and not to the connectors on the system board.
Entering the AVAGO MegaRAID BIOS configuration utility
This section provides instructions on how to enter the AVAGO MegaRAID BIOS configuration utility.
To enter the AVAGO MegaRAID BIOS configuration utility, do the following:
1. During the computer startup, follow the instructions on the screen.
2. Press Ctrl+H to enter the CONTROLLER SELECTION window.
3. Select the controller you want to configure, and then click
Start
to enter the AVAGO MegaRAID BIOS
configuration utility.
Creating RAID volumes using the AVAGO MegaRAID BIOS configuration utility
This section provides instructions on how to create RAID volumes using the AVAGO MegaRAID BIOS
configuration utility.
To create RAID volumes using the AVAGO MegaRAID BIOS configuration utility, do the following:
75
Содержание ThinkStation P910
Страница 1: ...P910 Hardware Maintenance Manual Machine Types 30B8 and 30B9 ...
Страница 14: ...8 P910 Hardware Maintenance Manual ...
Страница 18: ...12 P910 Hardware Maintenance Manual ...
Страница 19: ...1 2 Chapter 1 Read this first Important safety information 13 ...
Страница 20: ...1 2 14 P910 Hardware Maintenance Manual ...
Страница 25: ...1 2 Chapter 1 Read this first Important safety information 19 ...
Страница 26: ...1 2 20 P910 Hardware Maintenance Manual ...
Страница 29: ...Chapter 1 Read this first Important safety information 23 ...
Страница 39: ...b f d c e Chapter 2 Product overview 33 ...
Страница 52: ...46 P910 Hardware Maintenance Manual ...
Страница 64: ...58 P910 Hardware Maintenance Manual ...
Страница 84: ...78 P910 Hardware Maintenance Manual ...
Страница 98: ...92 P910 Hardware Maintenance Manual ...
Страница 106: ...100 P910 Hardware Maintenance Manual ...
Страница 224: ...218 P910 Hardware Maintenance Manual ...
Страница 226: ...220 P910 Hardware Maintenance Manual ...
Страница 228: ...222 P910 Hardware Maintenance Manual ...
Страница 236: ...230 P910 Hardware Maintenance Manual ...
Страница 240: ...4 Follow the instructions on the screen 234 P910 Hardware Maintenance Manual ...
Страница 243: ......
Страница 244: ......